<?xml version="1.0" encoding="UTF-8" ?>
<oai_dc:dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title>A Novel Digital Technique to Quantify the Area and Volume of Enamel Removal after Interproximal Enamel Reduction</dc:title>
<dc:creator>Triduo, Martina</dc:creator>
<dc:creator>Zubizarreta Macho, Álvaro</dc:creator>
<dc:creator>Alonso Pérez-Barquero, Jorge</dc:creator>
<dc:creator>Guinot Barona, Clara</dc:creator>
<dc:creator>Alvarado Lorenzo, Alfonso</dc:creator>
<dc:creator>Vicente Galindo, Purificación</dc:creator>
<dc:creator>Albaladejo Martínez, Alberto</dc:creator>
<dc:subject>Orthodontics</dc:subject>
<dc:subject>Morphometry</dc:subject>
<dc:subject>Interproximal reduction</dc:subject>
<dc:subject>Enamel removed and stripping</dc:subject>
<dc:subject>Dentistry</dc:subject>
<dc:subject>Digital impression</dc:subject>
<dc:subject>3213.13 Ortodoncia-Estomatología</dc:subject>
<dc:subject>32 Ciencias Médicas</dc:subject>
<dc:description>The aim of this study was to show a novel and accurate digital measurement protocol by analyzing the area and volume for interproximal tooth enamel surface reduction. In total, 14 lower teeth from all dental sectors were embedded into an epoxy resin and distributed as the lower dental arch, keeping the contact points. The experimental model was submitted to an intraoral digital impression before and after interproximal tooth enamel surface reduction using air-rotor strips and then re-contouring and polishing the interproximal enamel surfaces. These steps helped obtain standard tessellation language (STL) digital files. Furthermore, each tooth in the preoperative and postoperative full-arch STL digital files was segmented individually and aligned to analyze the area and volume of the interproximal tooth enamel surface reduction using engineering morphometry software. Descriptive analysis of the area and volume of the interproximal tooth enamel surface reduction was performed using a Student t-test. Higher enamel reduction area (3.53 3.08 mm2) and volume (0.32 0.22 mm3) values were shown on the distal surface compared with the area (2.97 3.05 mm2) and volume (0.22 0.16 mm3) of the enamel reduction on the mesial surface measured using the morphometric measurement digital protocol. The morphometric measurement protocol is an accurate digital measurement protocol for analyzing the area and volume of interproximal enamel surface reduction.</dc:description>
<dc:description>Odontología</dc:description>
<dc:date>2023-12-21T15:26:45Z</dc:date>
<dc:date>2023-12-21T15:26:45Z</dc:date>
<dc:date>2021-01-30</dc:date>
<dc:type>article</dc:type>
<dc:identifier>Triduo, M.; Zubizarreta-Macho, Á.; Pérez-Barquero, J.A.; Guinot Barona, C.; Alvarado Lorenzo, A.; Vicente-Galindo, P.; Albaladejo Martínez, A. A Novel Digital Technique to Quantify the Area and Volume of Enamel Removal after Interproximal Enamel Reduction. Appl. Sci. 2021, 11, 1274. https:// doi.org/10.3390/app11031274</dc:identifier>
<dc:identifier>http://hdl.handle.net/20.500.12466/3373</dc:identifier>
<dc:identifier>https://doi.org/10.3390/app11031274</dc:identifier>
<dc:identifier>2076-3417</dc:identifier>
<dc:language>eng</dc:language>
<dc:rights>Atribución 4.0 Internacional</dc:rights>
<dc:rights>http://creativecommons.org/licenses/by/4.0/</dc:rights>
<dc:rights>openAccess</dc:rights>
<dc:source>https://www.mdpi.com/journal/applsci</dc:source>
</oai_dc:dc>
<?xml version="1.0" encoding="UTF-8" ?>
<rdf:RDF schemaLocation="http://www.w3.org/1999/02/22-rdf-syntax-ns# http://www.europeana.eu/schemas/edm/EDM.xsd">
<edm:ProvidedCHO about="http://hdl.handle.net/20.500.12466/3373">
<dc:creator>Triduo, Martina</dc:creator>
<dc:creator>Zubizarreta Macho, Álvaro</dc:creator>
<dc:creator>Alonso Pérez-Barquero, Jorge</dc:creator>
<dc:creator>Guinot Barona, Clara</dc:creator>
<dc:creator>Alvarado Lorenzo, Alfonso</dc:creator>
<dc:creator>Vicente Galindo, Purificación</dc:creator>
<dc:creator>Albaladejo Martínez, Alberto</dc:creator>
<dc:date>2021-01-30</dc:date>
<dc:description>The aim of this study was to show a novel and accurate digital measurement protocol by analyzing the area and volume for interproximal tooth enamel surface reduction. In total, 14 lower teeth from all dental sectors were embedded into an epoxy resin and distributed as the lower dental arch, keeping the contact points. The experimental model was submitted to an intraoral digital impression before and after interproximal tooth enamel surface reduction using air-rotor strips and then re-contouring and polishing the interproximal enamel surfaces. These steps helped obtain standard tessellation language (STL) digital files. Furthermore, each tooth in the preoperative and postoperative full-arch STL digital files was segmented individually and aligned to analyze the area and volume of the interproximal tooth enamel surface reduction using engineering morphometry software. Descriptive analysis of the area and volume of the interproximal tooth enamel surface reduction was performed using a Student t-test. Higher enamel reduction area (3.53 3.08 mm2) and volume (0.32 0.22 mm3) values were shown on the distal surface compared with the area (2.97 3.05 mm2) and volume (0.22 0.16 mm3) of the enamel reduction on the mesial surface measured using the morphometric measurement digital protocol. The morphometric measurement protocol is an accurate digital measurement protocol for analyzing the area and volume of interproximal enamel surface reduction.</dc:description>
<dc:identifier>http://hdl.handle.net/20.500.12466/3373</dc:identifier>
<dc:language>eng</dc:language>
<dc:source>https://www.mdpi.com/journal/applsci</dc:source>
<dc:subject>Orthodontics</dc:subject>
<dc:subject>Morphometry</dc:subject>
<dc:subject>Interproximal reduction</dc:subject>
<dc:subject>Enamel removed and stripping</dc:subject>
<dc:subject>Dentistry</dc:subject>
<dc:subject>Digital impression</dc:subject>
<dc:subject>3213.13 Ortodoncia-Estomatología</dc:subject>
<dc:subject>32 Ciencias Médicas</dc:subject>
<dc:title>A Novel Digital Technique to Quantify the Area and Volume of Enamel Removal after Interproximal Enamel Reduction</dc:title>
<dc:type>article</dc:type>
<edm:type>TEXT</edm:type>
</edm:ProvidedCHO>
<ore:Aggregation about="http://hdl.handle.net/20.500.12466/3373#aggregation">
<edm:dataProvider>Repositorio Institucional de la Universidad Católica de Valencia San Vicente Mártir</edm:dataProvider>
<edm:provider>Hispana</edm:provider>
</ore:Aggregation>
<edm:WebResource about="https://riucv.ucv.es/bitstream/20.500.12466/3373/1/A%20Novel%20Digital%20Technique%20%282%29.pdf">
</edm:WebResource>
</rdf:RDF>