<dc:title>A new concept in constructed wetlands: assessment of aerobic electroconductive biofilters</dc:title>
<dc:creator>Aguirre-Sierra, A.</dc:creator>
<dc:creator>Bacchetti, T.</dc:creator>
<dc:creator>Salas, J.J.</dc:creator>
<dc:creator>De Deus, A.</dc:creator>
<dc:creator>Esteve-Núñez, A.</dc:creator>
<dc:subject>QS Ecology</dc:subject>
<dc:subject>QD Chemistry</dc:subject>
<dc:subject>TD Environmental technology. Sanitary engineering</dc:subject>
<dc:description>The METland® concept constitutes a hybrid concept for treating wastewater where microbial electrochemical technologies (MET) are integrated with constructed wetlands (CW) to enhance pollutant removal. Although electroactive bacteria (EAB) were thought to be restricted to anaerobic environments, we decided to explore alternative aerobic conditions like those found in down flow vertical CW. Two electroconductive (EC) biofilters fed with real urban wastewater were operated under downflow (aerobic) and upflow (anaerobic) conditions. The objective was to evaluate the impact of the operational mode on both the removal of pollutants and the microbial community profile. Surprisingly, despite the aerobic nature of the downflow EC biofilter, our results revealed an abundance of EAB from the Geobacter genus, opening a new scenario for treating wastewater based on stimulating extracellular electron transfer. Furthermore, the co-presence of Geobacter and Thiobacillus suggests the existence of interspecies electron transfer leading to nitrate respiration in our system. Moreover, the downflow EC biofilter outperformed the anaerobic upflow one in terms of COD, BOD5 and nitrogen removal.</dc:description>
<dc:publisher>Royal Society of Chemistry</dc:publisher>
<dc:date>2020-03-12</dc:date>
<dc:type>Article</dc:type>
<dc:type>PeerReviewed</dc:type>
<dc:format>text</dc:format>
<dc:identifier>http://eprints.imdea-agua.org:13000/1156/1/Aguirre-Sierra_etal_EnvSci%20WatResTech.docx</dc:identifier>
<dc:relation>https://doi.org/10.1039/C9EW00696F</dc:relation>
<dc:identifier>Aguirre-Sierra, A. and Bacchetti, T. and Salas, J.J. and De Deus, A. and Esteve-Núñez, A. (2020) A new concept in constructed wetlands: assessment of aerobic electroconductive biofilters. Environmental Science: Water Research & Technology. ISSN 2053-1419</dc:identifier>
<dc:relation>http://eprints.imdea-agua.org:13000/1156/</dc:relation>
</oai_dc:dc>
<?xml version="1.0" encoding="UTF-8" ?>
<didl:DIDL DIDLDocumentId="http://eprints.imdea-agua.org:13000/id/eprint/1156" schemaLocation="urn:mpeg:mpeg21:2002:02-DIDL-NS http://standards.iso.org/ittf/PubliclyAvailableStandards/MPEG-21_schema_files/did/didl.xsd urn:mpeg:mpeg21:2002:01-DII-NS http://standards.iso.org/ittf/PubliclyAvailableStandards/MPEG-21_schema_files/dii/dii.xsd urn:mpeg:mpeg21:2005:01-DIP-NS http://standards.iso.org/ittf/PubliclyAvailableStandards/MPEG-21_schema_files/dip/dip.xsd">
<didl:Item>
<didl:Descriptor>
<didl:Statement mimeType="application/xml">
<dii:Identifier>http://eprints.imdea-agua.org:13000/id/eprint/1156</dii:Identifier>
</didl:Statement>
</didl:Descriptor>
<didl:Descriptor>
<didl:Statement mimeType="application/xml">
<dcterms:modified>2020-03-23T11:25:06Z</dcterms:modified>
</didl:Statement>
</didl:Descriptor>
<didl:Component>
</didl:Component>
<didl:Item>
<didl:Descriptor>
<didl:Statement mimeType="application/xml">
<dip:ObjectType>info:eu-repo/semantics/descriptiveMetadata</dip:ObjectType>
</didl:Statement>
</didl:Descriptor>
<didl:Component>
<didl:Resource mimeType="application/xml">
<oai_dc:dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title>A new concept in constructed wetlands: assessment of aerobic electroconductive biofilters</dc:title>
<dc:creator>Aguirre-Sierra, A.</dc:creator>
<dc:creator>Bacchetti, T.</dc:creator>
<dc:creator>Salas, J.J.</dc:creator>
<dc:creator>De Deus, A.</dc:creator>
<dc:creator>Esteve-Núñez, A.</dc:creator>
<dc:subject>QS Ecology</dc:subject>
<dc:subject>QD Chemistry</dc:subject>
<dc:subject>TD Environmental technology. Sanitary engineering</dc:subject>
<dc:description>The METland® concept constitutes a hybrid concept for treating wastewater where microbial electrochemical technologies (MET) are integrated with constructed wetlands (CW) to enhance pollutant removal. Although electroactive bacteria (EAB) were thought to be restricted to anaerobic environments, we decided to explore alternative aerobic conditions like those found in down flow vertical CW. Two electroconductive (EC) biofilters fed with real urban wastewater were operated under downflow (aerobic) and upflow (anaerobic) conditions. The objective was to evaluate the impact of the operational mode on both the removal of pollutants and the microbial community profile. Surprisingly, despite the aerobic nature of the downflow EC biofilter, our results revealed an abundance of EAB from the Geobacter genus, opening a new scenario for treating wastewater based on stimulating extracellular electron transfer. Furthermore, the co-presence of Geobacter and Thiobacillus suggests the existence of interspecies electron transfer leading to nitrate respiration in our system. Moreover, the downflow EC biofilter outperformed the anaerobic upflow one in terms of COD, BOD5 and nitrogen removal.</dc:description>
<dc:publisher>Royal Society of Chemistry</dc:publisher>
<dc:date>2020-03-12</dc:date>
<dc:type>Article</dc:type>
<dc:type>PeerReviewed</dc:type>
<dc:format>text</dc:format>
<dc:identifier>http://eprints.imdea-agua.org:13000/1156/1/Aguirre-Sierra_etal_EnvSci%20WatResTech.docx</dc:identifier>
<dc:relation>https://doi.org/10.1039/C9EW00696F</dc:relation>
<dc:identifier>Aguirre-Sierra, A. and Bacchetti, T. and Salas, J.J. and De Deus, A. and Esteve-Núñez, A. (2020) A new concept in constructed wetlands: assessment of aerobic electroconductive biofilters. Environmental Science: Water Research & Technology. ISSN 2053-1419</dc:identifier>
<dc:relation>http://eprints.imdea-agua.org:13000/1156/</dc:relation>
</oai_dc:dc>
</didl:Resource>
</didl:Component>
</didl:Item>
<didl:Item>
<didl:Descriptor>
<didl:Statement mimeType="application/xml">
<dip:ObjectType>info:eu-repo/semantics/objectFile</dip:ObjectType>
</didl:Statement>
</didl:Descriptor>
<didl:Component>
</didl:Component>
</didl:Item>
<didl:Item>
<didl:Descriptor>
<didl:Statement mimeType="application/xml">
<dip:ObjectType>info:eu-repo/semantics/humanStartPage</dip:ObjectType>
</didl:Statement>
</didl:Descriptor>
<didl:Component>
</didl:Component>
</didl:Item>
</didl:Item>
</didl:DIDL>
<?xml version="1.0" encoding="UTF-8" ?>
<mets:mets LABEL="Eprints Item" OBJID="eprint_1156" schemaLocation="http://www.loc.gov/METS/ http://www.loc.gov/standards/mets/mets.xsd http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-3.xsd">
<mets:metsHdr CREATEDATE="2022-09-20T09:13:51Z">
<mets:agent ROLE="CUSTODIAN" TYPE="ORGANIZATION">
<mets:name>IMDEA AGUA</mets:name>
</mets:agent>
</mets:metsHdr>
<mets:dmdSec ID="DMD_eprint_1156_mods">
<mets:mdWrap MDTYPE="MODS">
<mets:xmlData>
<mods:titleInfo>
<mods:title>A new concept in constructed wetlands: assessment of aerobic electroconductive biofilters</mods:title>
</mods:titleInfo>
<mods:name type="personal">
<mods:namePart type="given">A.</mods:namePart>
<mods:namePart type="family">Aguirre-Sierra</mods:namePart>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
</mods:name>
<mods:name type="personal">
<mods:namePart type="given">T.</mods:namePart>
<mods:namePart type="family">Bacchetti</mods:namePart>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
</mods:name>
<mods:name type="personal">
<mods:namePart type="given">J.J.</mods:namePart>
<mods:namePart type="family">Salas</mods:namePart>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
</mods:name>
<mods:name type="personal">
<mods:namePart type="given">A.</mods:namePart>
<mods:namePart type="family">De Deus</mods:namePart>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
</mods:name>
<mods:name type="personal">
<mods:namePart type="given">A.</mods:namePart>
<mods:namePart type="family">Esteve-Núñez</mods:namePart>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
</mods:name>
<mods:abstract>The METland® concept constitutes a hybrid concept for treating wastewater where microbial electrochemical technologies (MET) are integrated with constructed wetlands (CW) to enhance pollutant removal. Although electroactive bacteria (EAB) were thought to be restricted to anaerobic environments, we decided to explore alternative aerobic conditions like those found in down flow vertical CW. Two electroconductive (EC) biofilters fed with real urban wastewater were operated under downflow (aerobic) and upflow (anaerobic) conditions. The objective was to evaluate the impact of the operational mode on both the removal of pollutants and the microbial community profile. Surprisingly, despite the aerobic nature of the downflow EC biofilter, our results revealed an abundance of EAB from the Geobacter genus, opening a new scenario for treating wastewater based on stimulating extracellular electron transfer. Furthermore, the co-presence of Geobacter and Thiobacillus suggests the existence of interspecies electron transfer leading to nitrate respiration in our system. Moreover, the downflow EC biofilter outperformed the anaerobic upflow one in terms of COD, BOD5 and nitrogen removal.</mods:abstract>
<mods:classification authority="lcc">QS Ecology</mods:classification>
<mods:classification authority="lcc">QD Chemistry</mods:classification>
<mods:classification authority="lcc">TD Environmental technology. Sanitary engineering</mods:classification>
<mods:originInfo>
<mods:dateIssued encoding="iso8061">2020-03-12</mods:dateIssued>
</mods:originInfo>
<mods:originInfo>
<mods:publisher>Royal Society of Chemistry</mods:publisher>
</mods:originInfo>
<mods:genre>Article</mods:genre>
</mets:xmlData>
</mets:mdWrap>
</mets:dmdSec>
<mets:amdSec ID="TMD_eprint_1156">
<mets:rightsMD ID="rights_eprint_1156_mods">
<mets:mdWrap MDTYPE="MODS">
<mets:xmlData>
<mods:useAndReproduction>
<p>
<strong>For work being deposited by its own author:</strong>
</p>
<p>
<strong>For work being deposited by someone other than its author:</strong>
</p>
<p>Clicking on the deposit button indicates your agreement to these terms.</p>
</mods:useAndReproduction>
</mets:xmlData>
</mets:mdWrap>
</mets:rightsMD>
</mets:amdSec>
<mets:fileSec>
<mets:fileGrp USE="reference">
<mets:file ID="eprint_1156_1189_1" MIMETYPE="application/vnd.openxmlformats-officedocument.wordprocessingml.document" OWNERID="http://eprints.imdea-agua.org:13000/1156/1/Aguirre-Sierra_etal_EnvSci%20WatResTech.docx" SIZE="8730082">
</mets:file>
</mets:fileGrp>
</mets:fileSec>
<mets:structMap>
<mets:div ADMID="TMD_eprint_1156" DMDID="DMD_eprint_1156_mods">
</mets:div>
</mets:structMap>
</mets:mets>
<?xml version="1.0" encoding="UTF-8" ?>
<?xml version="1.0" encoding="UTF-8" ?>
<rdf:RDF>
<rdf:Description about="">
<rdfs:comment datatype="http://www.w3.org/2001/XMLSchema#string">The repository administrator has not yet configured an RDF license.</rdfs:comment>
</rdf:Description>
<rdf:Description about="http://eprints.imdea-agua.org:13000/1156/2/indexcodes.txt">
<rdfs:label datatype="http://www.w3.org/2001/XMLSchema#string">indexcodes.txt</rdfs:label>
</rdf:Description>
<rdf:Description about="http://eprints.imdea-agua.org:13000/1156/">
<dc:format>text/html</dc:format>
<dc:title>HTML Summary of #1156 A new concept in constructed wetlands: assessment of aerobic electroconductive biofilters</dc:title>
</rdf:Description>
<rdf:Description about="http://eprints.imdea-agua.org:13000/id/document/1189">
<rdfs:label datatype="http://www.w3.org/2001/XMLSchema#string">A new concept in constructed wetlands: assessment of aerobic electroconductive biofilters (Text)</rdfs:label>
</rdf:Description>
<rdf:Description about="http://eprints.imdea-agua.org:13000/id/document/1190">
<rdfs:label datatype="http://www.w3.org/2001/XMLSchema#string">A new concept in constructed wetlands: assessment of aerobic electroconductive biofilters (Other)</rdfs:label>
</rdf:Description>
<rdf:Description about="http://eprints.imdea-agua.org:13000/id/eprint/1156#authors">
</rdf:Description>
<rdf:Description about="http://eprints.imdea-agua.org:13000/id/eprint/1156">
<bibo:abstract datatype="http://www.w3.org/2001/XMLSchema#string">The METland® concept constitutes a hybrid concept for treating wastewater where microbial electrochemical technologies (MET) are integrated with constructed wetlands (CW) to enhance pollutant removal. Although electroactive bacteria (EAB) were thought to be restricted to anaerobic environments, we decided to explore alternative aerobic conditions like those found in down flow vertical CW. Two electroconductive (EC) biofilters fed with real urban wastewater were operated under downflow (aerobic) and upflow (anaerobic) conditions. The objective was to evaluate the impact of the operational mode on both the removal of pollutants and the microbial community profile. Surprisingly, despite the aerobic nature of the downflow EC biofilter, our results revealed an abundance of EAB from the Geobacter genus, opening a new scenario for treating wastewater based on stimulating extracellular electron transfer. Furthermore, the co-presence of Geobacter and Thiobacillus suggests the existence of interspecies electron transfer leading to nitrate respiration in our system. Moreover, the downflow EC biofilter outperformed the anaerobic upflow one in terms of COD, BOD5 and nitrogen removal.</bibo:abstract>
<dct:date>2020-03-12</dct:date>
<dct:title datatype="http://www.w3.org/2001/XMLSchema#string">A new concept in constructed wetlands: assessment of aerobic electroconductive biofilters</dct:title>
</rdf:Description>
<rdf:Description about="http://eprints.imdea-agua.org:13000/id/subject/Ecology">
<skos:prefLabel>QS Ecology</skos:prefLabel>
</rdf:Description>
<rdf:Description about="http://eprints.imdea-agua.org:13000/id/subject/QD">
<skos:prefLabel lang="en">QD Chemistry</skos:prefLabel>
</rdf:Description>
<rdf:Description about="http://eprints.imdea-agua.org:13000/id/subject/TD">
<skos:prefLabel lang="en">TD Environmental technology. Sanitary engineering</skos:prefLabel>
</rdf:Description>
<rdf:Description about="http://eprints.imdea-agua.org:13000/id/org/ext-0d10f2788536102d641991e98c2e842a">
<foaf:name datatype="http://www.w3.org/2001/XMLSchema#string">Department of Analytical Chemistry and Chemical Engineering, University of Alcalá, E-28805 Alcalá de Henares, Madrid, Spain</foaf:name>
</rdf:Description>
<rdf:Description about="http://eprints.imdea-agua.org:13000/id/org/ext-703fc74c1189f593646a838631a00b2e">
<foaf:name datatype="http://www.w3.org/2001/XMLSchema#string">Royal Society of Chemistry</foaf:name>
</rdf:Description>
<rdf:Description about="http://eprints.imdea-agua.org:13000/id/org/ext-614340726490683713c9b5f502f76ff6">
<foaf:name datatype="http://www.w3.org/2001/XMLSchema#string">IMDEA Agua, Parque Científico Tecnológico, E-28805 Alcalá de Henares, Madrid, Spain</foaf:name>
</rdf:Description>
<rdf:Description about="http://eprints.imdea-agua.org:13000/id/org/ext-d7123a29395b52bfe0912d7db5ec9a17">
<foaf:name datatype="http://www.w3.org/2001/XMLSchema#string">Foundation Centre for New Water Technologies (CENTA), E-41820 Carrión de los Céspedes, Sevilla, Spain</foaf:name>
</rdf:Description>
<rdf:Description about="http://eprints.imdea-agua.org:13000/id/person/ext-58f6fa410094fcd779e2fce02092fd97">
<foaf:familyName datatype="http://www.w3.org/2001/XMLSchema#string">De Deus</foaf:familyName>
<foaf:givenName datatype="http://www.w3.org/2001/XMLSchema#string">A.</foaf:givenName>
<foaf:name datatype="http://www.w3.org/2001/XMLSchema#string">A. De Deus</foaf:name>
</rdf:Description>
<rdf:Description about="http://eprints.imdea-agua.org:13000/id/person/ext-82199da78114ba72e12e9e526bf5145c">
<foaf:familyName datatype="http://www.w3.org/2001/XMLSchema#string">Bacchetti</foaf:familyName>
<foaf:givenName datatype="http://www.w3.org/2001/XMLSchema#string">T.</foaf:givenName>
<foaf:name datatype="http://www.w3.org/2001/XMLSchema#string">T. Bacchetti</foaf:name>
</rdf:Description>
<rdf:Description about="http://eprints.imdea-agua.org:13000/id/person/ext-abraham.esteve@imdea.org">
<foaf:familyName datatype="http://www.w3.org/2001/XMLSchema#string">Esteve-Núñez</foaf:familyName>
<foaf:givenName datatype="http://www.w3.org/2001/XMLSchema#string">A.</foaf:givenName>
<foaf:name datatype="http://www.w3.org/2001/XMLSchema#string">A. Esteve-Núñez</foaf:name>
</rdf:Description>
<rdf:Description about="http://eprints.imdea-agua.org:13000/id/person/ext-d27d7f9105ba1c4896a0d76814a68101">
<foaf:familyName datatype="http://www.w3.org/2001/XMLSchema#string">Aguirre-Sierra</foaf:familyName>
<foaf:givenName datatype="http://www.w3.org/2001/XMLSchema#string">A.</foaf:givenName>
<foaf:name datatype="http://www.w3.org/2001/XMLSchema#string">A. Aguirre-Sierra</foaf:name>
</rdf:Description>
<rdf:Description about="http://eprints.imdea-agua.org:13000/id/person/ext-dd6c2a01abb96ea93ad9fe358f738848">
<foaf:familyName datatype="http://www.w3.org/2001/XMLSchema#string">Salas</foaf:familyName>
<foaf:givenName datatype="http://www.w3.org/2001/XMLSchema#string">J.J.</foaf:givenName>
<foaf:name datatype="http://www.w3.org/2001/XMLSchema#string">J.J. Salas</foaf:name>
</rdf:Description>
<rdf:Description about="http://eprints.imdea-agua.org:13000/id/publication/ext-20531419">
<bibo:issn>20531419</bibo:issn>
<foaf:name datatype="http://www.w3.org/2001/XMLSchema#string">Environmental Science: Water Research & Technology</foaf:name>
</rdf:Description>
</rdf:RDF>
<?xml version="1.0" encoding="UTF-8" ?>