<?xml version="1.0" encoding="UTF-8" ?>
<oai_dc:dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title>3D subject-specific shape and density modeling of the lumbar spine from 2D DXA images for osteoporosis assessment</dc:title>
<dc:creator>López Picazo, Mirella</dc:creator>
<dc:contributor>González Ballester, Miguel Ángel</dc:contributor>
<dc:contributor>Humbert, Ludovic</dc:contributor>
<dc:contributor>Universitat Pompeu Fabra. Departament de Tecnologies de la Informació i les Comunicacions</dc:contributor>
<dc:subject>3D modeling</dc:subject>
<dc:subject>Statistical shape model</dc:subject>
<dc:subject>Statistical appearance model</dc:subject>
<dc:subject>Image registration</dc:subject>
<dc:subject>Lumbar spine</dc:subject>
<dc:subject>Vertebra</dc:subject>
<dc:subject>Osteoporosis</dc:subject>
<dc:subject>Volumetric bone mineral density</dc:subject>
<dc:subject>Cortical bone</dc:subject>
<dc:subject>Trabecular bone</dc:subject>
<dc:subject>Fracture risk</dc:subject>
<dc:subject>62</dc:subject>
<dc:description>Osteoporosis is the most common bone disease, with a significant morbidity and mortality caused by the increase of bone fragility and susceptibility to fracture. Dual Energy X-ray Absorptiometry (DXA) is the gold standard technique for osteoporosis and fracture risk evaluation at the spine. However, the standard analysis of DXA images only provides 2D measurements and does not differentiate between bone compartments; neither specifically assess bone density in the vertebral body, which is where most of the osteoporotic fractures occur. Quantitative Computed Tomography (QCT) is an alternative technique that overcomes limitations of DXA-based diagnosis. However, due to the high cost and radiation dose, QCT is not used for osteoporosis management. In this thesis, a method providing a 3D subject-specific shape and density estimation of the lumbar spine from a single anteroposterior DXA image is proposed. The method is based on a 3D statistical shape and density model built from a training set of QCT scans. The 3D subject-specific shape and density estimation is obtained by registering and fitting the statistical model onto the DXA image. Cortical and trabecular bone compartments are segmented using a model-based algorithm. 3D measurements are performed at different vertebral regions and bone compartments. The accuracy of the proposed methods is evaluated by comparing DXA-derived to QCT-derived 3D measurements. Two case-control studies are also performed: a retrospective study evaluating the ability of DXA-derived 3D measurements at lumbar spine to discriminate between osteoporosis-related vertebral fractures and control groups; and a study evaluating the association between DXA-derived 3D measurements at lumbar spine and osteoporosis-related hip fractures. In both studies, stronger associations are found between osteoporosis-related fractures and DXA-derived 3D measurements compared to standard 2D measurements. The technology developed within this thesis offers an insightful 3D analysis of the lumbar spine, which could potentially improve osteoporosis and fracture risk assessment in patients who had a standard DXA scan of the lumbar spine without any additional examination.</dc:description>
<dc:description>La osteoporosis es la enfermedad ósea más común, con una morbilidad y mortalidad significativas causadas por el aumento de la fragilidad ósea y la susceptibilidad a las fracturas. La absorciometría de rayos X de energía dual (DXA, por sus siglas en inglés) es la técnica de referencia para la evaluación de la osteoporosis y del riesgo de fracturas en la columna vertebral. Sin embargo, el análisis estándar de las imágenes DXA solo proporciona mediciones 2D y no diferencia entre los compartimentos óseos; tampoco evalúa la densidad ósea en el cuerpo vertebral, que es donde se producen la mayoría de las fracturas osteoporóticas. La tomografía computarizada cuantitativa (QCT, por sus siglas en inglés) es una técnica alternativa que supera las limitaciones del diagnóstico basado en DXA. Sin embargo, debido al alto costo y la dosis de radiación, la QCT no se usa para el diagnóstico de la osteoporosis. En esta tesis, se propone un método que proporciona una estimación personalizada de la forma 3D y la densidad de la columna vertebral en la zona lumbar a partir de una única imagen DXA anteroposterior. El método se basa en un modelo estadístico 3D de forma y densidad creado a partir de un conjunto de entrenamiento de exploraciones QCT. La estimación 3D personalizada de forma y densidad se obtiene al registrar y ajustar el modelo estadístico con la imagen DXA. Se segmentan los compartimentos óseos corticales y trabeculares utilizando un algoritmo basado en modelos. Se realizan mediciones 3D en diferentes regiones vertebrales y compartimentos óseos. La precisión de los métodos propuestos se evalúa comparando las mediciones 3D derivadas de DXA con las derivadas de QCT. También se realizan dos estudios de casos y controles: un estudio retrospectivo que evalúa la capacidad de las mediciones 3D derivadas de DXA en la columna lumbar para discriminar entre sujetos con fracturas vertebrales relacionadas con la osteoporosis y sujetos control; y un estudio que evalúa la asociación entre las mediciones 3D derivadas de DXA en la columna lumbar y las fracturas de cadera relacionadas con la osteoporosis. En ambos estudios, se encuentran asociaciones más fuertes entre las fracturas relacionadas con la osteoporosis y las mediciones 3D derivadas de DXA en comparación con las mediciones estándar 2D. La tecnología desarrollada dentro de esta tesis ofrece un análisis en 3D de la columna lumbar, que podría mejorar la evaluación de la osteoporosis y el riesgo de fractura en pacientes que se sometieron a una exploración DXA estándar de la columna lumbar sin ningún examen adicional.</dc:description>
<dc:description>Programa de doctorat en Tecnologies de la Informació i les Comunicacions</dc:description>
<dc:date>2019-03-27T11:57:12Z</dc:date>
<dc:date>2020-03-18T01:00:12Z</dc:date>
<dc:date>2019-03-19</dc:date>
<dc:type>info:eu-repo/semantics/doctoralThesis</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:identifier>http://hdl.handle.net/10803/666513</dc:identifier>
<dc:language>eng</dc:language>
<dc:rights>ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.</dc:rights>
<dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
<dc:format>182 p.</dc:format>
<dc:format>application/pdf</dc:format>
<dc:format>application/pdf</dc:format>
<dc:publisher>Universitat Pompeu Fabra</dc:publisher>
<dc:source>TDX (Tesis Doctorals en Xarxa)</dc:source>
</oai_dc:dc>
<?xml version="1.0" encoding="UTF-8" ?>
<dim:dim schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
<dim:field element="contributor" mdschema="dc">Universitat Pompeu Fabra. Departament de Tecnologies de la Informació i les Comunicacions</dim:field>
<dim:field authority="d7121cf4-6f8f-4fc5-ae26-0280d666eb8f" confidence="-1" element="contributor" mdschema="dc" qualifier="author">López Picazo, Mirella</dim:field>
<dim:field element="contributor" lang="en_US" mdschema="dc" qualifier="authoremail">mirella.lopez01@estudiant.upf.edu</dim:field>
<dim:field element="contributor" lang="en_US" mdschema="dc" qualifier="authoremailshow">true</dim:field>
<dim:field authority="78c25316-230f-4068-a273-f8eb8f116772" confidence="-1" element="contributor" mdschema="dc" qualifier="director">González Ballester, Miguel Ángel</dim:field>
<dim:field authority="0f121804-7de0-40f0-b1d8-a3d2926b5978" confidence="-1" element="contributor" mdschema="dc" qualifier="director">Humbert, Ludovic</dim:field>
<dim:field element="date" mdschema="dc" qualifier="accessioned">2019-03-27T11:57:12Z</dim:field>
<dim:field element="date" mdschema="dc" qualifier="available">2020-03-18T01:00:12Z</dim:field>
<dim:field element="date" mdschema="dc" qualifier="issued">2019-03-19</dim:field>
<dim:field element="identifier" mdschema="dc" qualifier="uri">http://hdl.handle.net/10803/666513</dim:field>
<dim:field element="description" lang="en_US" mdschema="dc" qualifier="abstract">Osteoporosis is the most common bone disease, with a significant morbidity and mortality caused by the increase of bone fragility and susceptibility to fracture. Dual Energy X-ray Absorptiometry (DXA) is the gold standard technique for osteoporosis and fracture risk evaluation at the spine. However, the standard analysis of DXA images only provides 2D measurements and does not differentiate between bone compartments; neither specifically assess bone density in the vertebral body, which is where most of the osteoporotic fractures occur. Quantitative Computed Tomography (QCT) is an alternative technique that overcomes limitations of DXA-based diagnosis. However, due to the high cost and radiation dose, QCT is not used for osteoporosis management. In this thesis, a method providing a 3D subject-specific shape and density estimation of the lumbar spine from a single anteroposterior DXA image is proposed. The method is based on a 3D statistical shape and density model built from a training set of QCT scans. The 3D subject-specific shape and density estimation is obtained by registering and fitting the statistical model onto the DXA image. Cortical and trabecular bone compartments are segmented using a model-based algorithm. 3D measurements are performed at different vertebral regions and bone compartments. The accuracy of the proposed methods is evaluated by comparing DXA-derived to QCT-derived 3D measurements. Two case-control studies are also performed: a retrospective study evaluating the ability of DXA-derived 3D measurements at lumbar spine to discriminate between osteoporosis-related vertebral fractures and control groups; and a study evaluating the association between DXA-derived 3D measurements at lumbar spine and osteoporosis-related hip fractures. In both studies, stronger associations are found between osteoporosis-related fractures and DXA-derived 3D measurements compared to standard 2D measurements. The technology developed within this thesis offers an insightful 3D analysis of the lumbar spine, which could potentially improve osteoporosis and fracture risk assessment in patients who had a standard DXA scan of the lumbar spine without any additional examination.</dim:field>
<dim:field element="description" lang="en_US" mdschema="dc" qualifier="abstract">La osteoporosis es la enfermedad ósea más común, con una morbilidad y mortalidad significativas causadas por el aumento de la fragilidad ósea y la susceptibilidad a las fracturas. La absorciometría de rayos X de energía dual (DXA, por sus siglas en inglés) es la técnica de referencia para la evaluación de la osteoporosis y del riesgo de fracturas en la columna vertebral. Sin embargo, el análisis estándar de las imágenes DXA solo proporciona mediciones 2D y no diferencia entre los compartimentos óseos; tampoco evalúa la densidad ósea en el cuerpo vertebral, que es donde se producen la mayoría de las fracturas osteoporóticas. La tomografía computarizada cuantitativa (QCT, por sus siglas en inglés) es una técnica alternativa que supera las limitaciones del diagnóstico basado en DXA. Sin embargo, debido al alto costo y la dosis de radiación, la QCT no se usa para el diagnóstico de la osteoporosis. En esta tesis, se propone un método que proporciona una estimación personalizada de la forma 3D y la densidad de la columna vertebral en la zona lumbar a partir de una única imagen DXA anteroposterior. El método se basa en un modelo estadístico 3D de forma y densidad creado a partir de un conjunto de entrenamiento de exploraciones QCT. La estimación 3D personalizada de forma y densidad se obtiene al registrar y ajustar el modelo estadístico con la imagen DXA. Se segmentan los compartimentos óseos corticales y trabeculares utilizando un algoritmo basado en modelos. Se realizan mediciones 3D en diferentes regiones vertebrales y compartimentos óseos. La precisión de los métodos propuestos se evalúa comparando las mediciones 3D derivadas de DXA con las derivadas de QCT. También se realizan dos estudios de casos y controles: un estudio retrospectivo que evalúa la capacidad de las mediciones 3D derivadas de DXA en la columna lumbar para discriminar entre sujetos con fracturas vertebrales relacionadas con la osteoporosis y sujetos control; y un estudio que evalúa la asociación entre las mediciones 3D derivadas de DXA en la columna lumbar y las fracturas de cadera relacionadas con la osteoporosis. En ambos estudios, se encuentran asociaciones más fuertes entre las fracturas relacionadas con la osteoporosis y las mediciones 3D derivadas de DXA en comparación con las mediciones estándar 2D. La tecnología desarrollada dentro de esta tesis ofrece un análisis en 3D de la columna lumbar, que podría mejorar la evaluación de la osteoporosis y el riesgo de fractura en pacientes que se sometieron a una exploración DXA estándar de la columna lumbar sin ningún examen adicional.</dim:field>
<dim:field element="description" mdschema="dc" qualifier="degree">Programa de doctorat en Tecnologies de la Informació i les Comunicacions</dim:field>
<dim:field element="format" lang="en_US" mdschema="dc" qualifier="extent">182 p.</dim:field>
<dim:field element="format" mdschema="dc" qualifier="mimetype">application/pdf</dim:field>
<dim:field element="language" lang="en_US" mdschema="dc" qualifier="iso">eng</dim:field>
<dim:field element="publisher" mdschema="dc">Universitat Pompeu Fabra</dim:field>
<dim:field element="rights" mdschema="dc" qualifier="license">ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.</dim:field>
<dim:field element="rights" mdschema="dc" qualifier="accessLevel">info:eu-repo/semantics/openAccess</dim:field>
<dim:field element="source" mdschema="dc">TDX (Tesis Doctorals en Xarxa)</dim:field>
<dim:field element="subject" lang="en_US" mdschema="dc">3D modeling</dim:field>
<dim:field element="subject" lang="en_US" mdschema="dc">Statistical shape model</dim:field>
<dim:field element="subject" lang="en_US" mdschema="dc">Statistical appearance model</dim:field>
<dim:field element="subject" lang="en_US" mdschema="dc">Image registration</dim:field>
<dim:field element="subject" lang="en_US" mdschema="dc">Lumbar spine</dim:field>
<dim:field element="subject" lang="en_US" mdschema="dc">Vertebra</dim:field>
<dim:field element="subject" lang="en_US" mdschema="dc">Osteoporosis</dim:field>
<dim:field element="subject" lang="en_US" mdschema="dc">Volumetric bone mineral density</dim:field>
<dim:field element="subject" lang="en_US" mdschema="dc">Cortical bone</dim:field>
<dim:field element="subject" lang="en_US" mdschema="dc">Trabecular bone</dim:field>
<dim:field element="subject" lang="en_US" mdschema="dc">Fracture risk</dim:field>
<dim:field element="subject" lang="en_US" mdschema="dc" qualifier="udc">62</dim:field>
<dim:field element="title" lang="en_US" mdschema="dc">3D subject-specific shape and density modeling of the lumbar spine from 2D DXA images for osteoporosis assessment</dim:field>
<dim:field element="type" mdschema="dc">info:eu-repo/semantics/doctoralThesis</dim:field>
<dim:field element="type" mdschema="dc">info:eu-repo/semantics/publishedVersion</dim:field>
<dim:field element="embargo" lang="en_US" mdschema="dc" qualifier="terms">12 mesos</dim:field>
</dim:dim>
<?xml version="1.0" encoding="UTF-8" ?>
<thesis schemaLocation="http://www.ndltd.org/standards/metadata/etdms/1.0/ http://www.ndltd.org/standards/metadata/etdms/1.0/etdms.xsd">
<title>3D subject-specific shape and density modeling of the lumbar spine from 2D DXA images for osteoporosis assessment</title>
<creator>López Picazo, Mirella</creator>
<contributor>mirella.lopez01@estudiant.upf.edu</contributor>
<contributor>true</contributor>
<contributor>González Ballester, Miguel Ángel</contributor>
<contributor>Humbert, Ludovic</contributor>
<subject>3D modeling</subject>
<subject>Statistical shape model</subject>
<subject>Statistical appearance model</subject>
<subject>Image registration</subject>
<subject>Lumbar spine</subject>
<subject>Vertebra</subject>
<subject>Osteoporosis</subject>
<subject>Volumetric bone mineral density</subject>
<subject>Cortical bone</subject>
<subject>Trabecular bone</subject>
<subject>Fracture risk</subject>
<description>Osteoporosis is the most common bone disease, with a significant morbidity and mortality caused by the increase of bone fragility and susceptibility to fracture. Dual Energy X-ray Absorptiometry (DXA) is the gold standard technique for osteoporosis and fracture risk evaluation at the spine. However, the standard analysis of DXA images only provides 2D measurements and does not differentiate between bone compartments; neither specifically assess bone density in the vertebral body, which is where most of the osteoporotic fractures occur. Quantitative Computed Tomography (QCT) is an alternative technique that overcomes limitations of DXA-based diagnosis. However, due to the high cost and radiation dose, QCT is not used for osteoporosis management. In this thesis, a method providing a 3D subject-specific shape and density estimation of the lumbar spine from a single anteroposterior DXA image is proposed. The method is based on a 3D statistical shape and density model built from a training set of QCT scans. The 3D subject-specific shape and density estimation is obtained by registering and fitting the statistical model onto the DXA image. Cortical and trabecular bone compartments are segmented using a model-based algorithm. 3D measurements are performed at different vertebral regions and bone compartments. The accuracy of the proposed methods is evaluated by comparing DXA-derived to QCT-derived 3D measurements. Two case-control studies are also performed: a retrospective study evaluating the ability of DXA-derived 3D measurements at lumbar spine to discriminate between osteoporosis-related vertebral fractures and control groups; and a study evaluating the association between DXA-derived 3D measurements at lumbar spine and osteoporosis-related hip fractures. In both studies, stronger associations are found between osteoporosis-related fractures and DXA-derived 3D measurements compared to standard 2D measurements. The technology developed within this thesis offers an insightful 3D analysis of the lumbar spine, which could potentially improve osteoporosis and fracture risk assessment in patients who had a standard DXA scan of the lumbar spine without any additional examination.</description>
<description>La osteoporosis es la enfermedad ósea más común, con una morbilidad y mortalidad significativas causadas por el aumento de la fragilidad ósea y la susceptibilidad a las fracturas. La absorciometría de rayos X de energía dual (DXA, por sus siglas en inglés) es la técnica de referencia para la evaluación de la osteoporosis y del riesgo de fracturas en la columna vertebral. Sin embargo, el análisis estándar de las imágenes DXA solo proporciona mediciones 2D y no diferencia entre los compartimentos óseos; tampoco evalúa la densidad ósea en el cuerpo vertebral, que es donde se producen la mayoría de las fracturas osteoporóticas. La tomografía computarizada cuantitativa (QCT, por sus siglas en inglés) es una técnica alternativa que supera las limitaciones del diagnóstico basado en DXA. Sin embargo, debido al alto costo y la dosis de radiación, la QCT no se usa para el diagnóstico de la osteoporosis. En esta tesis, se propone un método que proporciona una estimación personalizada de la forma 3D y la densidad de la columna vertebral en la zona lumbar a partir de una única imagen DXA anteroposterior. El método se basa en un modelo estadístico 3D de forma y densidad creado a partir de un conjunto de entrenamiento de exploraciones QCT. La estimación 3D personalizada de forma y densidad se obtiene al registrar y ajustar el modelo estadístico con la imagen DXA. Se segmentan los compartimentos óseos corticales y trabeculares utilizando un algoritmo basado en modelos. Se realizan mediciones 3D en diferentes regiones vertebrales y compartimentos óseos. La precisión de los métodos propuestos se evalúa comparando las mediciones 3D derivadas de DXA con las derivadas de QCT. También se realizan dos estudios de casos y controles: un estudio retrospectivo que evalúa la capacidad de las mediciones 3D derivadas de DXA en la columna lumbar para discriminar entre sujetos con fracturas vertebrales relacionadas con la osteoporosis y sujetos control; y un estudio que evalúa la asociación entre las mediciones 3D derivadas de DXA en la columna lumbar y las fracturas de cadera relacionadas con la osteoporosis. En ambos estudios, se encuentran asociaciones más fuertes entre las fracturas relacionadas con la osteoporosis y las mediciones 3D derivadas de DXA en comparación con las mediciones estándar 2D. La tecnología desarrollada dentro de esta tesis ofrece un análisis en 3D de la columna lumbar, que podría mejorar la evaluación de la osteoporosis y el riesgo de fractura en pacientes que se sometieron a una exploración DXA estándar de la columna lumbar sin ningún examen adicional.</description>
<date>2019-03-27</date>
<date>2020-03-18</date>
<date>2019-03-19</date>
<type>info:eu-repo/semantics/doctoralThesis</type>
<type>info:eu-repo/semantics/publishedVersion</type>
<identifier>http://hdl.handle.net/10803/666513</identifier>
<language>eng</language>
<rights>ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.</rights>
<rights>info:eu-repo/semantics/openAccess</rights>
<publisher>Universitat Pompeu Fabra</publisher>
<source>TDX (Tesis Doctorals en Xarxa)</source>
</thesis>
<?xml version="1.0" encoding="UTF-8" ?>
<record schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<leader>00925njm 22002777a 4500</leader>
<datafield ind1=" " ind2=" " tag="042">
<subfield code="a">dc</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="720">
<subfield code="a">López Picazo, Mirella</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="260">
<subfield code="c">2019-03-19</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="520">
<subfield code="a">Osteoporosis is the most common bone disease, with a significant morbidity and mortality caused by the increase of bone fragility and susceptibility to fracture. Dual Energy X-ray Absorptiometry (DXA) is the gold standard technique for osteoporosis and fracture risk evaluation at the spine. However, the standard analysis of DXA images only provides 2D measurements and does not differentiate between bone compartments; neither specifically assess bone density in the vertebral body, which is where most of the osteoporotic fractures occur. Quantitative Computed Tomography (QCT) is an alternative technique that overcomes limitations of DXA-based diagnosis. However, due to the high cost and radiation dose, QCT is not used for osteoporosis management. In this thesis, a method providing a 3D subject-specific shape and density estimation of the lumbar spine from a single anteroposterior DXA image is proposed. The method is based on a 3D statistical shape and density model built from a training set of QCT scans. The 3D subject-specific shape and density estimation is obtained by registering and fitting the statistical model onto the DXA image. Cortical and trabecular bone compartments are segmented using a model-based algorithm. 3D measurements are performed at different vertebral regions and bone compartments. The accuracy of the proposed methods is evaluated by comparing DXA-derived to QCT-derived 3D measurements. Two case-control studies are also performed: a retrospective study evaluating the ability of DXA-derived 3D measurements at lumbar spine to discriminate between osteoporosis-related vertebral fractures and control groups; and a study evaluating the association between DXA-derived 3D measurements at lumbar spine and osteoporosis-related hip fractures. In both studies, stronger associations are found between osteoporosis-related fractures and DXA-derived 3D measurements compared to standard 2D measurements. The technology developed within this thesis offers an insightful 3D analysis of the lumbar spine, which could potentially improve osteoporosis and fracture risk assessment in patients who had a standard DXA scan of the lumbar spine without any additional examination.</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="520">
<subfield code="a">La osteoporosis es la enfermedad ósea más común, con una morbilidad y mortalidad significativas causadas por el aumento de la fragilidad ósea y la susceptibilidad a las fracturas. La absorciometría de rayos X de energía dual (DXA, por sus siglas en inglés) es la técnica de referencia para la evaluación de la osteoporosis y del riesgo de fracturas en la columna vertebral. Sin embargo, el análisis estándar de las imágenes DXA solo proporciona mediciones 2D y no diferencia entre los compartimentos óseos; tampoco evalúa la densidad ósea en el cuerpo vertebral, que es donde se producen la mayoría de las fracturas osteoporóticas. La tomografía computarizada cuantitativa (QCT, por sus siglas en inglés) es una técnica alternativa que supera las limitaciones del diagnóstico basado en DXA. Sin embargo, debido al alto costo y la dosis de radiación, la QCT no se usa para el diagnóstico de la osteoporosis. En esta tesis, se propone un método que proporciona una estimación personalizada de la forma 3D y la densidad de la columna vertebral en la zona lumbar a partir de una única imagen DXA anteroposterior. El método se basa en un modelo estadístico 3D de forma y densidad creado a partir de un conjunto de entrenamiento de exploraciones QCT. La estimación 3D personalizada de forma y densidad se obtiene al registrar y ajustar el modelo estadístico con la imagen DXA. Se segmentan los compartimentos óseos corticales y trabeculares utilizando un algoritmo basado en modelos. Se realizan mediciones 3D en diferentes regiones vertebrales y compartimentos óseos. La precisión de los métodos propuestos se evalúa comparando las mediciones 3D derivadas de DXA con las derivadas de QCT. También se realizan dos estudios de casos y controles: un estudio retrospectivo que evalúa la capacidad de las mediciones 3D derivadas de DXA en la columna lumbar para discriminar entre sujetos con fracturas vertebrales relacionadas con la osteoporosis y sujetos control; y un estudio que evalúa la asociación entre las mediciones 3D derivadas de DXA en la columna lumbar y las fracturas de cadera relacionadas con la osteoporosis. En ambos estudios, se encuentran asociaciones más fuertes entre las fracturas relacionadas con la osteoporosis y las mediciones 3D derivadas de DXA en comparación con las mediciones estándar 2D. La tecnología desarrollada dentro de esta tesis ofrece un análisis en 3D de la columna lumbar, que podría mejorar la evaluación de la osteoporosis y el riesgo de fractura en pacientes que se sometieron a una exploración DXA estándar de la columna lumbar sin ningún examen adicional.</subfield>
</datafield>
<datafield ind1="8" ind2=" " tag="024">
<subfield code="a">http://hdl.handle.net/10803/666513</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">3D modeling</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Statistical shape model</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Statistical appearance model</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Image registration</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Lumbar spine</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Vertebra</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Osteoporosis</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Volumetric bone mineral density</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Cortical bone</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Trabecular bone</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Fracture risk</subfield>
</datafield>
<datafield ind1="0" ind2="0" tag="245">
<subfield code="a">3D subject-specific shape and density modeling of the lumbar spine from 2D DXA images for osteoporosis assessment</subfield>
</datafield>
</record>
<?xml version="1.0" encoding="UTF-8" ?>
<record schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<leader>nam a 5i 4500</leader>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">3D modeling</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Statistical shape model</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Statistical appearance model</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Image registration</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Lumbar spine</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Vertebra</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Osteoporosis</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Volumetric bone mineral density</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Cortical bone</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Trabecular bone</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Fracture risk</subfield>
</datafield>
<datafield ind1="1" ind2="0" tag="245">
<subfield code="a">3D subject-specific shape and density modeling of the lumbar spine from 2D DXA images for osteoporosis assessment</subfield>
</datafield>
<datafield ind1=" " ind2="1" tag="264">
<subfield code="a">[Barcelona] :</subfield>
<subfield code="b">Universitat Pompeu Fabra,</subfield>
<subfield code="c">2019</subfield>
</datafield>
<datafield ind1="4" ind2="0" tag="856">
<subfield code="z">Accés lliure</subfield>
<subfield code="u">http://hdl.handle.net/10803/666513</subfield>
</datafield>
<controlfield tag="007">cr |||||||||||</controlfield>
<controlfield tag="008">AAMMDDs2019 sp ||||fsm||||0|| 0 eng|c</controlfield>
<datafield ind1="1" ind2=" " tag="100">
<subfield code="a">López Picazo, Mirella,</subfield>
<subfield code="e">autor</subfield>
</datafield>
<datafield ind1="1" ind2=" " tag="100">
<subfield code="a">Programa de doctorat en Tecnologies de la Informació i les Comunicacions,</subfield>
<subfield code="e">degree</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="300">
<subfield code="a">1 recurs en línia (182 pàgines)</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="502">
<subfield code="g">Tesi</subfield>
<subfield code="b">Doctorat</subfield>
<subfield code="c">Universitat Pompeu Fabra. Departament de Tecnologies de la Informació i les Comunicacions</subfield>
<subfield code="d">2019</subfield>
</datafield>
<datafield ind1="2" ind2=" " tag="710">
<subfield code="a">Universitat Pompeu Fabra. Departament de Tecnologies de la Informació i les Comunicacions</subfield>
</datafield>
<datafield ind1=" " ind2="4" tag="655">
<subfield code="a">Tesis i dissertacions electròniques</subfield>
</datafield>
<datafield ind1="1" ind2=" " tag="700">
<subfield code="a">González Ballester, Miguel Ángel,</subfield>
<subfield code="e">supervisor acadèmic</subfield>
</datafield>
<datafield ind1="1" ind2=" " tag="700">
<subfield code="a">Humbert, Ludovic,</subfield>
<subfield code="e">supervisor acadèmic</subfield>
</datafield>
<datafield ind1="0" ind2=" " tag="730">
<subfield code="a">TDX</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="520">
<subfield code="a">Osteoporosis is the most common bone disease, with a significant morbidity and mortality caused by the increase of bone fragility and susceptibility to fracture. Dual Energy X-ray Absorptiometry (DXA) is the gold standard technique for osteoporosis and fracture risk evaluation at the spine. However, the standard analysis of DXA images only provides 2D measurements and does not differentiate between bone compartments; neither specifically assess bone density in the vertebral body, which is where most of the osteoporotic fractures occur. Quantitative Computed Tomography (QCT) is an alternative technique that overcomes limitations of DXA-based diagnosis. However, due to the high cost and radiation dose, QCT is not used for osteoporosis management. In this thesis, a method providing a 3D subject-specific shape and density estimation of the lumbar spine from a single anteroposterior DXA image is proposed. The method is based on a 3D statistical shape and density model built from a training set of QCT scans. The 3D subject-specific shape and density estimation is obtained by registering and fitting the statistical model onto the DXA image. Cortical and trabecular bone compartments are segmented using a model-based algorithm. 3D measurements are performed at different vertebral regions and bone compartments. The accuracy of the proposed methods is evaluated by comparing DXA-derived to QCT-derived 3D measurements. Two case-control studies are also performed: a retrospective study evaluating the ability of DXA-derived 3D measurements at lumbar spine to discriminate between osteoporosis-related vertebral fractures and control groups; and a study evaluating the association between DXA-derived 3D measurements at lumbar spine and osteoporosis-related hip fractures. In both studies, stronger associations are found between osteoporosis-related fractures and DXA-derived 3D measurements compared to standard 2D measurements. The technology developed within this thesis offers an insightful 3D analysis of the lumbar spine, which could potentially improve osteoporosis and fracture risk assessment in patients who had a standard DXA scan of the lumbar spine without any additional examination.</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="998">
<subfield code="a">f</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="040">
<subfield code="a">ES-BaCBU</subfield>
<subfield code="b">cat</subfield>
<subfield code="e">rda</subfield>
<subfield code="c">ES-BaCBU</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="336">
<subfield code="a">text</subfield>
<subfield code="b">txt</subfield>
<subfield code="2">rdacontent</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="337">
<subfield code="a">informàtic</subfield>
<subfield code="b">c</subfield>
<subfield code="2">rdamedia</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="338">
<subfield code="a">recurs en línia</subfield>
<subfield code="b">cr</subfield>
<subfield code="2">rdacarrier</subfield>
</datafield>
</record>
<?xml version="1.0" encoding="UTF-8" ?>
<mets ID=" DSpace_ITEM_10803-666513" OBJID=" hdl:10803/666513" PROFILE="DSpace METS SIP Profile 1.0" TYPE="DSpace ITEM" schemaLocation="http://www.loc.gov/METS/ http://www.loc.gov/standards/mets/mets.xsd">
<metsHdr CREATEDATE="2024-09-07T14:44:38Z">
<agent ROLE="CUSTODIAN" TYPE="ORGANIZATION">
<name>TDX (Tesis Doctorals en Xarxa)</name>
</agent>
</metsHdr>
<dmdSec ID="DMD_10803_666513">
<mdWrap MDTYPE="MODS">
<xmlData schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
<mods:mods schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
<mods:name>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
<mods:namePart>López Picazo, Mirella</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">authoremail</mods:roleTerm>
</mods:role>
<mods:namePart>mirella.lopez01@estudiant.upf.edu</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">authoremailshow</mods:roleTerm>
</mods:role>
<mods:namePart>true</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">director</mods:roleTerm>
</mods:role>
<mods:namePart>González Ballester, Miguel Ángel</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">director</mods:roleTerm>
</mods:role>
<mods:namePart>Humbert, Ludovic</mods:namePart>
</mods:name>
<mods:extension>
<mods:dateAccessioned encoding="iso8601">2019-03-27T11:57:12Z</mods:dateAccessioned>
</mods:extension>
<mods:extension>
<mods:dateAvailable encoding="iso8601">2020-03-18T01:00:12Z</mods:dateAvailable>
</mods:extension>
<mods:originInfo>
<mods:dateIssued encoding="iso8601">2019-03-19</mods:dateIssued>
</mods:originInfo>
<mods:identifier type="uri">http://hdl.handle.net/10803/666513</mods:identifier>
<mods:abstract>Osteoporosis is the most common bone disease, with a significant morbidity and mortality caused by the increase of bone fragility and susceptibility to fracture. Dual Energy X-ray Absorptiometry (DXA) is the gold standard technique for osteoporosis and fracture risk evaluation at the spine. However, the standard analysis of DXA images only provides 2D measurements and does not differentiate between bone compartments; neither specifically assess bone density in the vertebral body, which is where most of the osteoporotic fractures occur. Quantitative Computed Tomography (QCT) is an alternative technique that overcomes limitations of DXA-based diagnosis. However, due to the high cost and radiation dose, QCT is not used for osteoporosis management. In this thesis, a method providing a 3D subject-specific shape and density estimation of the lumbar spine from a single anteroposterior DXA image is proposed. The method is based on a 3D statistical shape and density model built from a training set of QCT scans. The 3D subject-specific shape and density estimation is obtained by registering and fitting the statistical model onto the DXA image. Cortical and trabecular bone compartments are segmented using a model-based algorithm. 3D measurements are performed at different vertebral regions and bone compartments. The accuracy of the proposed methods is evaluated by comparing DXA-derived to QCT-derived 3D measurements. Two case-control studies are also performed: a retrospective study evaluating the ability of DXA-derived 3D measurements at lumbar spine to discriminate between osteoporosis-related vertebral fractures and control groups; and a study evaluating the association between DXA-derived 3D measurements at lumbar spine and osteoporosis-related hip fractures. In both studies, stronger associations are found between osteoporosis-related fractures and DXA-derived 3D measurements compared to standard 2D measurements. The technology developed within this thesis offers an insightful 3D analysis of the lumbar spine, which could potentially improve osteoporosis and fracture risk assessment in patients who had a standard DXA scan of the lumbar spine without any additional examination.La osteoporosis es la enfermedad ósea más común, con una morbilidad y mortalidad significativas causadas por el aumento de la fragilidad ósea y la susceptibilidad a las fracturas. La absorciometría de rayos X de energía dual (DXA, por sus siglas en inglés) es la técnica de referencia para la evaluación de la osteoporosis y del riesgo de fracturas en la columna vertebral. Sin embargo, el análisis estándar de las imágenes DXA solo proporciona mediciones 2D y no diferencia entre los compartimentos óseos; tampoco evalúa la densidad ósea en el cuerpo vertebral, que es donde se producen la mayoría de las fracturas osteoporóticas. La tomografía computarizada cuantitativa (QCT, por sus siglas en inglés) es una técnica alternativa que supera las limitaciones del diagnóstico basado en DXA. Sin embargo, debido al alto costo y la dosis de radiación, la QCT no se usa para el diagnóstico de la osteoporosis. En esta tesis, se propone un método que proporciona una estimación personalizada de la forma 3D y la densidad de la columna vertebral en la zona lumbar a partir de una única imagen DXA anteroposterior. El método se basa en un modelo estadístico 3D de forma y densidad creado a partir de un conjunto de entrenamiento de exploraciones QCT. La estimación 3D personalizada de forma y densidad se obtiene al registrar y ajustar el modelo estadístico con la imagen DXA. Se segmentan los compartimentos óseos corticales y trabeculares utilizando un algoritmo basado en modelos. Se realizan mediciones 3D en diferentes regiones vertebrales y compartimentos óseos. La precisión de los métodos propuestos se evalúa comparando las mediciones 3D derivadas de DXA con las derivadas de QCT. También se realizan dos estudios de casos y controles: un estudio retrospectivo que evalúa la capacidad de las mediciones 3D derivadas de DXA en la columna lumbar para discriminar entre sujetos con fracturas vertebrales relacionadas con la osteoporosis y sujetos control; y un estudio que evalúa la asociación entre las mediciones 3D derivadas de DXA en la columna lumbar y las fracturas de cadera relacionadas con la osteoporosis. En ambos estudios, se encuentran asociaciones más fuertes entre las fracturas relacionadas con la osteoporosis y las mediciones 3D derivadas de DXA en comparación con las mediciones estándar 2D. La tecnología desarrollada dentro de esta tesis ofrece un análisis en 3D de la columna lumbar, que podría mejorar la evaluación de la osteoporosis y el riesgo de fractura en pacientes que se sometieron a una exploración DXA estándar de la columna lumbar sin ningún examen adicional.</mods:abstract>
<mods:language>
<mods:languageTerm authority="rfc3066">eng</mods:languageTerm>
</mods:language>
<mods:subject>
<mods:topic>3D modeling</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Statistical shape model</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Statistical appearance model</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Image registration</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Lumbar spine</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Vertebra</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Osteoporosis</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Volumetric bone mineral density</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Cortical bone</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Trabecular bone</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Fracture risk</mods:topic>
</mods:subject>
<mods:titleInfo>
<mods:title>3D subject-specific shape and density modeling of the lumbar spine from 2D DXA images for osteoporosis assessment</mods:title>
</mods:titleInfo>
<mods:genre>info:eu-repo/semantics/doctoralThesis info:eu-repo/semantics/publishedVersion</mods:genre>
</mods:mods>
</xmlData>
</mdWrap>
</dmdSec>
<amdSec ID="FO_10803_666513_1">
<techMD ID="TECH_O_10803_666513_1">
<mdWrap MDTYPE="PREMIS">
<xmlData schemaLocation="http://www.loc.gov/standards/premis http://www.loc.gov/standards/premis/PREMIS-v1-0.xsd">
<premis:premis>
<premis:object>
<premis:objectIdentifier>
<premis:objectIdentifierType>URL</premis:objectIdentifierType>
<premis:objectIdentifierValue>https://www.tdx.cat/bitstream/10803/666513/1/tmlp.pdf</premis:objectIdentifierValue>
</premis:objectIdentifier>
<premis:objectCategory>File</premis:objectCategory>
<premis:objectCharacteristics>
<premis:fixity>
<premis:messageDigestAlgorithm>MD5</premis:messageDigestAlgorithm>
<premis:messageDigest>87d358c1ea74cb8166523e56982039a4</premis:messageDigest>
</premis:fixity>
<premis:size>3358998</premis:size>
<premis:format>
<premis:formatDesignation>
<premis:formatName>application/pdf</premis:formatName>
</premis:formatDesignation>
</premis:format>
</premis:objectCharacteristics>
<premis:originalName>tmlp.pdf</premis:originalName>
</premis:object>
</premis:premis>
</xmlData>
</mdWrap>
</techMD>
</amdSec>
<amdSec ID="FT_10803_666513_3">
<techMD ID="TECH_T_10803_666513_3">
<mdWrap MDTYPE="PREMIS">
<xmlData schemaLocation="http://www.loc.gov/standards/premis http://www.loc.gov/standards/premis/PREMIS-v1-0.xsd">
<premis:premis>
<premis:object>
<premis:objectIdentifier>
<premis:objectIdentifierType>URL</premis:objectIdentifierType>
<premis:objectIdentifierValue>https://www.tdx.cat/bitstream/10803/666513/3/tmlp.pdf.txt</premis:objectIdentifierValue>
</premis:objectIdentifier>
<premis:objectCategory>File</premis:objectCategory>
<premis:objectCharacteristics>
<premis:fixity>
<premis:messageDigestAlgorithm>MD5</premis:messageDigestAlgorithm>
<premis:messageDigest>e4aa3581d440a3be918bc4e4dbe166e9</premis:messageDigest>
</premis:fixity>
<premis:size>302312</premis:size>
<premis:format>
<premis:formatDesignation>
<premis:formatName>text/plain</premis:formatName>
</premis:formatDesignation>
</premis:format>
</premis:objectCharacteristics>
<premis:originalName>tmlp.pdf.txt</premis:originalName>
</premis:object>
</premis:premis>
</xmlData>
</mdWrap>
</techMD>
</amdSec>
<fileSec>
<fileGrp USE="ORIGINAL">
<file ADMID="FO_10803_666513_1" CHECKSUM="87d358c1ea74cb8166523e56982039a4" CHECKSUMTYPE="MD5" GROUPID="GROUP_BITSTREAM_10803_666513_1" ID="BITSTREAM_ORIGINAL_10803_666513_1" MIMETYPE="application/pdf" SEQ="1" SIZE="3358998">
</file>
</fileGrp>
<fileGrp USE="TEXT">
<file ADMID="FT_10803_666513_3" CHECKSUM="e4aa3581d440a3be918bc4e4dbe166e9" CHECKSUMTYPE="MD5" GROUPID="GROUP_BITSTREAM_10803_666513_3" ID="BITSTREAM_TEXT_10803_666513_3" MIMETYPE="text/plain" SEQ="3" SIZE="302312">
</file>
</fileGrp>
</fileSec>
<structMap LABEL="DSpace Object" TYPE="LOGICAL">
<div ADMID="DMD_10803_666513" TYPE="DSpace Object Contents">
<div TYPE="DSpace BITSTREAM">
</div>
</div>
</structMap>
</mets>
<?xml version="1.0" encoding="UTF-8" ?>
<mods:mods schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
<mods:name>
<mods:namePart>López Picazo, Mirella</mods:namePart>
</mods:name>
<mods:extension>
<mods:dateAvailable encoding="iso8601">2019-03-27T11:57:12Z</mods:dateAvailable>
</mods:extension>
<mods:extension>
<mods:dateAccessioned encoding="iso8601">2020-03-18T01:00:12Z</mods:dateAccessioned>
</mods:extension>
<mods:originInfo>
<mods:dateIssued encoding="iso8601">2019-03-19</mods:dateIssued>
</mods:originInfo>
<mods:identifier type="uri">http://hdl.handle.net/10803/666513</mods:identifier>
<mods:abstract>Osteoporosis is the most common bone disease, with a significant morbidity and mortality caused by the increase of bone fragility and susceptibility to fracture. Dual Energy X-ray Absorptiometry (DXA) is the gold standard technique for osteoporosis and fracture risk evaluation at the spine. However, the standard analysis of DXA images only provides 2D measurements and does not differentiate between bone compartments; neither specifically assess bone density in the vertebral body, which is where most of the osteoporotic fractures occur. Quantitative Computed Tomography (QCT) is an alternative technique that overcomes limitations of DXA-based diagnosis. However, due to the high cost and radiation dose, QCT is not used for osteoporosis management. In this thesis, a method providing a 3D subject-specific shape and density estimation of the lumbar spine from a single anteroposterior DXA image is proposed. The method is based on a 3D statistical shape and density model built from a training set of QCT scans. The 3D subject-specific shape and density estimation is obtained by registering and fitting the statistical model onto the DXA image. Cortical and trabecular bone compartments are segmented using a model-based algorithm. 3D measurements are performed at different vertebral regions and bone compartments. The accuracy of the proposed methods is evaluated by comparing DXA-derived to QCT-derived 3D measurements. Two case-control studies are also performed: a retrospective study evaluating the ability of DXA-derived 3D measurements at lumbar spine to discriminate between osteoporosis-related vertebral fractures and control groups; and a study evaluating the association between DXA-derived 3D measurements at lumbar spine and osteoporosis-related hip fractures. In both studies, stronger associations are found between osteoporosis-related fractures and DXA-derived 3D measurements compared to standard 2D measurements. The technology developed within this thesis offers an insightful 3D analysis of the lumbar spine, which could potentially improve osteoporosis and fracture risk assessment in patients who had a standard DXA scan of the lumbar spine without any additional examination.</mods:abstract>
<mods:abstract>La osteoporosis es la enfermedad ósea más común, con una morbilidad y mortalidad significativas causadas por el aumento de la fragilidad ósea y la susceptibilidad a las fracturas. La absorciometría de rayos X de energía dual (DXA, por sus siglas en inglés) es la técnica de referencia para la evaluación de la osteoporosis y del riesgo de fracturas en la columna vertebral. Sin embargo, el análisis estándar de las imágenes DXA solo proporciona mediciones 2D y no diferencia entre los compartimentos óseos; tampoco evalúa la densidad ósea en el cuerpo vertebral, que es donde se producen la mayoría de las fracturas osteoporóticas. La tomografía computarizada cuantitativa (QCT, por sus siglas en inglés) es una técnica alternativa que supera las limitaciones del diagnóstico basado en DXA. Sin embargo, debido al alto costo y la dosis de radiación, la QCT no se usa para el diagnóstico de la osteoporosis. En esta tesis, se propone un método que proporciona una estimación personalizada de la forma 3D y la densidad de la columna vertebral en la zona lumbar a partir de una única imagen DXA anteroposterior. El método se basa en un modelo estadístico 3D de forma y densidad creado a partir de un conjunto de entrenamiento de exploraciones QCT. La estimación 3D personalizada de forma y densidad se obtiene al registrar y ajustar el modelo estadístico con la imagen DXA. Se segmentan los compartimentos óseos corticales y trabeculares utilizando un algoritmo basado en modelos. Se realizan mediciones 3D en diferentes regiones vertebrales y compartimentos óseos. La precisión de los métodos propuestos se evalúa comparando las mediciones 3D derivadas de DXA con las derivadas de QCT. También se realizan dos estudios de casos y controles: un estudio retrospectivo que evalúa la capacidad de las mediciones 3D derivadas de DXA en la columna lumbar para discriminar entre sujetos con fracturas vertebrales relacionadas con la osteoporosis y sujetos control; y un estudio que evalúa la asociación entre las mediciones 3D derivadas de DXA en la columna lumbar y las fracturas de cadera relacionadas con la osteoporosis. En ambos estudios, se encuentran asociaciones más fuertes entre las fracturas relacionadas con la osteoporosis y las mediciones 3D derivadas de DXA en comparación con las mediciones estándar 2D. La tecnología desarrollada dentro de esta tesis ofrece un análisis en 3D de la columna lumbar, que podría mejorar la evaluación de la osteoporosis y el riesgo de fractura en pacientes que se sometieron a una exploración DXA estándar de la columna lumbar sin ningún examen adicional.</mods:abstract>
<mods:language>
<mods:languageTerm>eng</mods:languageTerm>
</mods:language>
<mods:accessCondition type="useAndReproduction">ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.</mods:accessCondition>
<mods:accessCondition type="useAndReproduction">info:eu-repo/semantics/openAccess</mods:accessCondition>
<mods:subject>
<mods:topic>3D modeling</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Statistical shape model</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Statistical appearance model</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Image registration</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Lumbar spine</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Vertebra</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Osteoporosis</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Volumetric bone mineral density</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Cortical bone</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Trabecular bone</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Fracture risk</mods:topic>
</mods:subject>
<mods:titleInfo>
<mods:title>3D subject-specific shape and density modeling of the lumbar spine from 2D DXA images for osteoporosis assessment</mods:title>
</mods:titleInfo>
<mods:genre>info:eu-repo/semantics/doctoralThesis</mods:genre>
<mods:genre>info:eu-repo/semantics/publishedVersion</mods:genre>
</mods:mods>
<?xml version="1.0" encoding="UTF-8" ?>
<oaire:record schemaLocation="http://namespaceopenaire.eu/schema/oaire/">
<dc:title>3D subject-specific shape and density modeling of the lumbar spine from 2D DXA images for osteoporosis assessment</dc:title>
<datacite:creator>
<datacite:creatorName>López Picazo, Mirella</datacite:creatorName>
</datacite:creator>
<datacite:contributor>mirella.lopez01@estudiant.upf.edu</datacite:contributor>
<datacite:contributor>true</datacite:contributor>
<datacite:contributor>González Ballester, Miguel Ángel</datacite:contributor>
<datacite:contributor>Humbert, Ludovic</datacite:contributor>
<datacite:contributor>Universitat Pompeu Fabra. Departament de Tecnologies de la Informació i les Comunicacions</datacite:contributor>
<dc:subject>3D modeling</dc:subject>
<dc:subject>Statistical shape model</dc:subject>
<dc:subject>Statistical appearance model</dc:subject>
<dc:subject>Image registration</dc:subject>
<dc:subject>Lumbar spine</dc:subject>
<dc:subject>Vertebra</dc:subject>
<dc:subject>Osteoporosis</dc:subject>
<dc:subject>Volumetric bone mineral density</dc:subject>
<dc:subject>Cortical bone</dc:subject>
<dc:subject>Trabecular bone</dc:subject>
<dc:subject>Fracture risk</dc:subject>
<dc:subject>62</dc:subject>
<dc:description>Osteoporosis is the most common bone disease, with a significant morbidity and mortality caused by the increase of bone fragility and susceptibility to fracture. Dual Energy X-ray Absorptiometry (DXA) is the gold standard technique for osteoporosis and fracture risk evaluation at the spine. However, the standard analysis of DXA images only provides 2D measurements and does not differentiate between bone compartments; neither specifically assess bone density in the vertebral body, which is where most of the osteoporotic fractures occur. Quantitative Computed Tomography (QCT) is an alternative technique that overcomes limitations of DXA-based diagnosis. However, due to the high cost and radiation dose, QCT is not used for osteoporosis management. In this thesis, a method providing a 3D subject-specific shape and density estimation of the lumbar spine from a single anteroposterior DXA image is proposed. The method is based on a 3D statistical shape and density model built from a training set of QCT scans. The 3D subject-specific shape and density estimation is obtained by registering and fitting the statistical model onto the DXA image. Cortical and trabecular bone compartments are segmented using a model-based algorithm. 3D measurements are performed at different vertebral regions and bone compartments. The accuracy of the proposed methods is evaluated by comparing DXA-derived to QCT-derived 3D measurements. Two case-control studies are also performed: a retrospective study evaluating the ability of DXA-derived 3D measurements at lumbar spine to discriminate between osteoporosis-related vertebral fractures and control groups; and a study evaluating the association between DXA-derived 3D measurements at lumbar spine and osteoporosis-related hip fractures. In both studies, stronger associations are found between osteoporosis-related fractures and DXA-derived 3D measurements compared to standard 2D measurements. The technology developed within this thesis offers an insightful 3D analysis of the lumbar spine, which could potentially improve osteoporosis and fracture risk assessment in patients who had a standard DXA scan of the lumbar spine without any additional examination.</dc:description>
<dc:description>La osteoporosis es la enfermedad ósea más común, con una morbilidad y mortalidad significativas causadas por el aumento de la fragilidad ósea y la susceptibilidad a las fracturas. La absorciometría de rayos X de energía dual (DXA, por sus siglas en inglés) es la técnica de referencia para la evaluación de la osteoporosis y del riesgo de fracturas en la columna vertebral. Sin embargo, el análisis estándar de las imágenes DXA solo proporciona mediciones 2D y no diferencia entre los compartimentos óseos; tampoco evalúa la densidad ósea en el cuerpo vertebral, que es donde se producen la mayoría de las fracturas osteoporóticas. La tomografía computarizada cuantitativa (QCT, por sus siglas en inglés) es una técnica alternativa que supera las limitaciones del diagnóstico basado en DXA. Sin embargo, debido al alto costo y la dosis de radiación, la QCT no se usa para el diagnóstico de la osteoporosis. En esta tesis, se propone un método que proporciona una estimación personalizada de la forma 3D y la densidad de la columna vertebral en la zona lumbar a partir de una única imagen DXA anteroposterior. El método se basa en un modelo estadístico 3D de forma y densidad creado a partir de un conjunto de entrenamiento de exploraciones QCT. La estimación 3D personalizada de forma y densidad se obtiene al registrar y ajustar el modelo estadístico con la imagen DXA. Se segmentan los compartimentos óseos corticales y trabeculares utilizando un algoritmo basado en modelos. Se realizan mediciones 3D en diferentes regiones vertebrales y compartimentos óseos. La precisión de los métodos propuestos se evalúa comparando las mediciones 3D derivadas de DXA con las derivadas de QCT. También se realizan dos estudios de casos y controles: un estudio retrospectivo que evalúa la capacidad de las mediciones 3D derivadas de DXA en la columna lumbar para discriminar entre sujetos con fracturas vertebrales relacionadas con la osteoporosis y sujetos control; y un estudio que evalúa la asociación entre las mediciones 3D derivadas de DXA en la columna lumbar y las fracturas de cadera relacionadas con la osteoporosis. En ambos estudios, se encuentran asociaciones más fuertes entre las fracturas relacionadas con la osteoporosis y las mediciones 3D derivadas de DXA en comparación con las mediciones estándar 2D. La tecnología desarrollada dentro de esta tesis ofrece un análisis en 3D de la columna lumbar, que podría mejorar la evaluación de la osteoporosis y el riesgo de fractura en pacientes que se sometieron a una exploración DXA estándar de la columna lumbar sin ningún examen adicional.</dc:description>
<dc:description>Programa de doctorat en Tecnologies de la Informació i les Comunicacions</dc:description>
<dc:date>2019-03-27T11:57:12Z</dc:date>
<dc:date>2020-03-18T01:00:12Z</dc:date>
<dc:date>2019-03-19</dc:date>
<dc:type>info:eu-repo/semantics/doctoralThesis</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<datacite:alternateIdentifier>http://hdl.handle.net/10803/666513</datacite:alternateIdentifier>
<dc:language>eng</dc:language>
<dc:rights>ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.</dc:rights>
<dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
<dc:format>182 p.</dc:format>
<dc:format>application/pdf</dc:format>
<dc:format>application/pdf</dc:format>
<dc:publisher>Universitat Pompeu Fabra</dc:publisher>
<dc:source>TDX (Tesis Doctorals en Xarxa)</dc:source>
<oaire:file>https://www.tdx.cat/bitstream/10803/666513/1/tmlp.pdf</oaire:file>
</oaire:record>
<?xml version="1.0" encoding="UTF-8" ?>
<atom:entry schemaLocation="http://www.w3.org/2005/Atom http://www.kbcafe.com/rss/atom.xsd.xml">
<atom:id>http://hdl.handle.net/10803/666513/ore.xml</atom:id>
<atom:published>2020-03-18T01:00:12Z</atom:published>
<atom:updated>2019-03-27T11:57:12Z</atom:updated>
<atom:source>
<atom:generator>TDX (Tesis Doctorals en Xarxa)</atom:generator>
</atom:source>
<atom:title>3D subject-specific shape and density modeling of the lumbar spine from 2D DXA images for osteoporosis assessment</atom:title>
<atom:author>
<atom:name>López Picazo, Mirella</atom:name>
</atom:author>
<oreatom:triples>
<rdf:Description about="http://hdl.handle.net/10803/666513/ore.xml#atom">
<dcterms:modified>2019-03-27T11:57:12Z</dcterms:modified>
</rdf:Description>
<rdf:Description about="https://www.tdx.cat/bitstream/10803/666513/3/tmlp.pdf.txt">
<dcterms:description>TEXT</dcterms:description>
</rdf:Description>
<rdf:Description about="https://www.tdx.cat/bitstream/10803/666513/1/tmlp.pdf">
<dcterms:description>ORIGINAL</dcterms:description>
</rdf:Description>
<rdf:Description about="https://www.tdx.cat/bitstream/10803/666513/2/tmlp.pdf.xml">
<dcterms:description>MEDIA_DOCUMENT</dcterms:description>
</rdf:Description>
</oreatom:triples>
</atom:entry>
<?xml version="1.0" encoding="UTF-8" ?>
<qdc:qualifieddc schemaLocation="http://purl.org/dc/elements/1.1/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dc.xsd http://purl.org/dc/terms/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dcterms.xsd http://dspace.org/qualifieddc/ http://www.ukoln.ac.uk/metadata/dcmi/xmlschema/qualifieddc.xsd">
<dc:title>3D subject-specific shape and density modeling of the lumbar spine from 2D DXA images for osteoporosis assessment</dc:title>
<dc:creator>López Picazo, Mirella</dc:creator>
<dc:contributor>González Ballester, Miguel Ángel</dc:contributor>
<dc:contributor>Humbert, Ludovic</dc:contributor>
<dc:subject>3D modeling</dc:subject>
<dc:subject>Statistical shape model</dc:subject>
<dc:subject>Statistical appearance model</dc:subject>
<dc:subject>Image registration</dc:subject>
<dc:subject>Lumbar spine</dc:subject>
<dc:subject>Vertebra</dc:subject>
<dc:subject>Osteoporosis</dc:subject>
<dc:subject>Volumetric bone mineral density</dc:subject>
<dc:subject>Cortical bone</dc:subject>
<dc:subject>Trabecular bone</dc:subject>
<dc:subject>Fracture risk</dc:subject>
<dcterms:abstract>Osteoporosis is the most common bone disease, with a significant morbidity and mortality caused by the increase of bone fragility and susceptibility to fracture. Dual Energy X-ray Absorptiometry (DXA) is the gold standard technique for osteoporosis and fracture risk evaluation at the spine. However, the standard analysis of DXA images only provides 2D measurements and does not differentiate between bone compartments; neither specifically assess bone density in the vertebral body, which is where most of the osteoporotic fractures occur. Quantitative Computed Tomography (QCT) is an alternative technique that overcomes limitations of DXA-based diagnosis. However, due to the high cost and radiation dose, QCT is not used for osteoporosis management. In this thesis, a method providing a 3D subject-specific shape and density estimation of the lumbar spine from a single anteroposterior DXA image is proposed. The method is based on a 3D statistical shape and density model built from a training set of QCT scans. The 3D subject-specific shape and density estimation is obtained by registering and fitting the statistical model onto the DXA image. Cortical and trabecular bone compartments are segmented using a model-based algorithm. 3D measurements are performed at different vertebral regions and bone compartments. The accuracy of the proposed methods is evaluated by comparing DXA-derived to QCT-derived 3D measurements. Two case-control studies are also performed: a retrospective study evaluating the ability of DXA-derived 3D measurements at lumbar spine to discriminate between osteoporosis-related vertebral fractures and control groups; and a study evaluating the association between DXA-derived 3D measurements at lumbar spine and osteoporosis-related hip fractures. In both studies, stronger associations are found between osteoporosis-related fractures and DXA-derived 3D measurements compared to standard 2D measurements. The technology developed within this thesis offers an insightful 3D analysis of the lumbar spine, which could potentially improve osteoporosis and fracture risk assessment in patients who had a standard DXA scan of the lumbar spine without any additional examination.</dcterms:abstract>
<dcterms:abstract>La osteoporosis es la enfermedad ósea más común, con una morbilidad y mortalidad significativas causadas por el aumento de la fragilidad ósea y la susceptibilidad a las fracturas. La absorciometría de rayos X de energía dual (DXA, por sus siglas en inglés) es la técnica de referencia para la evaluación de la osteoporosis y del riesgo de fracturas en la columna vertebral. Sin embargo, el análisis estándar de las imágenes DXA solo proporciona mediciones 2D y no diferencia entre los compartimentos óseos; tampoco evalúa la densidad ósea en el cuerpo vertebral, que es donde se producen la mayoría de las fracturas osteoporóticas. La tomografía computarizada cuantitativa (QCT, por sus siglas en inglés) es una técnica alternativa que supera las limitaciones del diagnóstico basado en DXA. Sin embargo, debido al alto costo y la dosis de radiación, la QCT no se usa para el diagnóstico de la osteoporosis. En esta tesis, se propone un método que proporciona una estimación personalizada de la forma 3D y la densidad de la columna vertebral en la zona lumbar a partir de una única imagen DXA anteroposterior. El método se basa en un modelo estadístico 3D de forma y densidad creado a partir de un conjunto de entrenamiento de exploraciones QCT. La estimación 3D personalizada de forma y densidad se obtiene al registrar y ajustar el modelo estadístico con la imagen DXA. Se segmentan los compartimentos óseos corticales y trabeculares utilizando un algoritmo basado en modelos. Se realizan mediciones 3D en diferentes regiones vertebrales y compartimentos óseos. La precisión de los métodos propuestos se evalúa comparando las mediciones 3D derivadas de DXA con las derivadas de QCT. También se realizan dos estudios de casos y controles: un estudio retrospectivo que evalúa la capacidad de las mediciones 3D derivadas de DXA en la columna lumbar para discriminar entre sujetos con fracturas vertebrales relacionadas con la osteoporosis y sujetos control; y un estudio que evalúa la asociación entre las mediciones 3D derivadas de DXA en la columna lumbar y las fracturas de cadera relacionadas con la osteoporosis. En ambos estudios, se encuentran asociaciones más fuertes entre las fracturas relacionadas con la osteoporosis y las mediciones 3D derivadas de DXA en comparación con las mediciones estándar 2D. La tecnología desarrollada dentro de esta tesis ofrece un análisis en 3D de la columna lumbar, que podría mejorar la evaluación de la osteoporosis y el riesgo de fractura en pacientes que se sometieron a una exploración DXA estándar de la columna lumbar sin ningún examen adicional.</dcterms:abstract>
<dcterms:dateAccepted>2020-03-18T01:00:12Z</dcterms:dateAccepted>
<dcterms:available>2020-03-18T01:00:12Z</dcterms:available>
<dcterms:created>2020-03-18T01:00:12Z</dcterms:created>
<dcterms:issued>2019-03-19</dcterms:issued>
<dc:type>info:eu-repo/semantics/doctoralThesis</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:identifier>http://hdl.handle.net/10803/666513</dc:identifier>
<dc:language>eng</dc:language>
<dc:rights>ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.</dc:rights>
<dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
<dc:publisher>Universitat Pompeu Fabra</dc:publisher>
<dc:source>TDX (Tesis Doctorals en Xarxa)</dc:source>
</qdc:qualifieddc>
<?xml version="1.0" encoding="UTF-8" ?>
<rdf:RDF schemaLocation="http://www.openarchives.org/OAI/2.0/rdf/ http://www.openarchives.org/OAI/2.0/rdf.xsd">
<ow:Publication about="oai:www.tdx.cat:10803/666513">
<dc:title>3D subject-specific shape and density modeling of the lumbar spine from 2D DXA images for osteoporosis assessment</dc:title>
<dc:creator>López Picazo, Mirella</dc:creator>
<dc:contributor>mirella.lopez01@estudiant.upf.edu</dc:contributor>
<dc:contributor>true</dc:contributor>
<dc:contributor>González Ballester, Miguel Ángel</dc:contributor>
<dc:contributor>Humbert, Ludovic</dc:contributor>
<dc:subject>3D modeling</dc:subject>
<dc:subject>Statistical shape model</dc:subject>
<dc:subject>Statistical appearance model</dc:subject>
<dc:subject>Image registration</dc:subject>
<dc:subject>Lumbar spine</dc:subject>
<dc:subject>Vertebra</dc:subject>
<dc:subject>Osteoporosis</dc:subject>
<dc:subject>Volumetric bone mineral density</dc:subject>
<dc:subject>Cortical bone</dc:subject>
<dc:subject>Trabecular bone</dc:subject>
<dc:subject>Fracture risk</dc:subject>
<dc:description>Osteoporosis is the most common bone disease, with a significant morbidity and mortality caused by the increase of bone fragility and susceptibility to fracture. Dual Energy X-ray Absorptiometry (DXA) is the gold standard technique for osteoporosis and fracture risk evaluation at the spine. However, the standard analysis of DXA images only provides 2D measurements and does not differentiate between bone compartments; neither specifically assess bone density in the vertebral body, which is where most of the osteoporotic fractures occur. Quantitative Computed Tomography (QCT) is an alternative technique that overcomes limitations of DXA-based diagnosis. However, due to the high cost and radiation dose, QCT is not used for osteoporosis management. In this thesis, a method providing a 3D subject-specific shape and density estimation of the lumbar spine from a single anteroposterior DXA image is proposed. The method is based on a 3D statistical shape and density model built from a training set of QCT scans. The 3D subject-specific shape and density estimation is obtained by registering and fitting the statistical model onto the DXA image. Cortical and trabecular bone compartments are segmented using a model-based algorithm. 3D measurements are performed at different vertebral regions and bone compartments. The accuracy of the proposed methods is evaluated by comparing DXA-derived to QCT-derived 3D measurements. Two case-control studies are also performed: a retrospective study evaluating the ability of DXA-derived 3D measurements at lumbar spine to discriminate between osteoporosis-related vertebral fractures and control groups; and a study evaluating the association between DXA-derived 3D measurements at lumbar spine and osteoporosis-related hip fractures. In both studies, stronger associations are found between osteoporosis-related fractures and DXA-derived 3D measurements compared to standard 2D measurements. The technology developed within this thesis offers an insightful 3D analysis of the lumbar spine, which could potentially improve osteoporosis and fracture risk assessment in patients who had a standard DXA scan of the lumbar spine without any additional examination.</dc:description>
<dc:description>La osteoporosis es la enfermedad ósea más común, con una morbilidad y mortalidad significativas causadas por el aumento de la fragilidad ósea y la susceptibilidad a las fracturas. La absorciometría de rayos X de energía dual (DXA, por sus siglas en inglés) es la técnica de referencia para la evaluación de la osteoporosis y del riesgo de fracturas en la columna vertebral. Sin embargo, el análisis estándar de las imágenes DXA solo proporciona mediciones 2D y no diferencia entre los compartimentos óseos; tampoco evalúa la densidad ósea en el cuerpo vertebral, que es donde se producen la mayoría de las fracturas osteoporóticas. La tomografía computarizada cuantitativa (QCT, por sus siglas en inglés) es una técnica alternativa que supera las limitaciones del diagnóstico basado en DXA. Sin embargo, debido al alto costo y la dosis de radiación, la QCT no se usa para el diagnóstico de la osteoporosis. En esta tesis, se propone un método que proporciona una estimación personalizada de la forma 3D y la densidad de la columna vertebral en la zona lumbar a partir de una única imagen DXA anteroposterior. El método se basa en un modelo estadístico 3D de forma y densidad creado a partir de un conjunto de entrenamiento de exploraciones QCT. La estimación 3D personalizada de forma y densidad se obtiene al registrar y ajustar el modelo estadístico con la imagen DXA. Se segmentan los compartimentos óseos corticales y trabeculares utilizando un algoritmo basado en modelos. Se realizan mediciones 3D en diferentes regiones vertebrales y compartimentos óseos. La precisión de los métodos propuestos se evalúa comparando las mediciones 3D derivadas de DXA con las derivadas de QCT. También se realizan dos estudios de casos y controles: un estudio retrospectivo que evalúa la capacidad de las mediciones 3D derivadas de DXA en la columna lumbar para discriminar entre sujetos con fracturas vertebrales relacionadas con la osteoporosis y sujetos control; y un estudio que evalúa la asociación entre las mediciones 3D derivadas de DXA en la columna lumbar y las fracturas de cadera relacionadas con la osteoporosis. En ambos estudios, se encuentran asociaciones más fuertes entre las fracturas relacionadas con la osteoporosis y las mediciones 3D derivadas de DXA en comparación con las mediciones estándar 2D. La tecnología desarrollada dentro de esta tesis ofrece un análisis en 3D de la columna lumbar, que podría mejorar la evaluación de la osteoporosis y el riesgo de fractura en pacientes que se sometieron a una exploración DXA estándar de la columna lumbar sin ningún examen adicional.</dc:description>
<dc:date>2019-03-27T11:57:12Z</dc:date>
<dc:date>2020-03-18T01:00:12Z</dc:date>
<dc:date>2019-03-19</dc:date>
<dc:type>info:eu-repo/semantics/doctoralThesis</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:identifier>http://hdl.handle.net/10803/666513</dc:identifier>
<dc:language>eng</dc:language>
<dc:rights>ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.</dc:rights>
<dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
<dc:publisher>Universitat Pompeu Fabra</dc:publisher>
<dc:source>TDX (Tesis Doctorals en Xarxa)</dc:source>
</ow:Publication>
</rdf:RDF>
<?xml version="1.0" encoding="UTF-8" ?>
<uketd_dc:uketddc schemaLocation="http://naca.central.cranfield.ac.uk/ethos-oai/2.0/ http://naca.central.cranfield.ac.uk/ethos-oai/2.0/uketd_dc.xsd">
<dc:title>3D subject-specific shape and density modeling of the lumbar spine from 2D DXA images for osteoporosis assessment</dc:title>
<dc:creator>López Picazo, Mirella</dc:creator>
<dcterms:abstract>Osteoporosis is the most common bone disease, with a significant morbidity and mortality caused by the increase of bone fragility and susceptibility to fracture. Dual Energy X-ray Absorptiometry (DXA) is the gold standard technique for osteoporosis and fracture risk evaluation at the spine. However, the standard analysis of DXA images only provides 2D measurements and does not differentiate between bone compartments; neither specifically assess bone density in the vertebral body, which is where most of the osteoporotic fractures occur. Quantitative Computed Tomography (QCT) is an alternative technique that overcomes limitations of DXA-based diagnosis. However, due to the high cost and radiation dose, QCT is not used for osteoporosis management. In this thesis, a method providing a 3D subject-specific shape and density estimation of the lumbar spine from a single anteroposterior DXA image is proposed. The method is based on a 3D statistical shape and density model built from a training set of QCT scans. The 3D subject-specific shape and density estimation is obtained by registering and fitting the statistical model onto the DXA image. Cortical and trabecular bone compartments are segmented using a model-based algorithm. 3D measurements are performed at different vertebral regions and bone compartments. The accuracy of the proposed methods is evaluated by comparing DXA-derived to QCT-derived 3D measurements. Two case-control studies are also performed: a retrospective study evaluating the ability of DXA-derived 3D measurements at lumbar spine to discriminate between osteoporosis-related vertebral fractures and control groups; and a study evaluating the association between DXA-derived 3D measurements at lumbar spine and osteoporosis-related hip fractures. In both studies, stronger associations are found between osteoporosis-related fractures and DXA-derived 3D measurements compared to standard 2D measurements. The technology developed within this thesis offers an insightful 3D analysis of the lumbar spine, which could potentially improve osteoporosis and fracture risk assessment in patients who had a standard DXA scan of the lumbar spine without any additional examination.</dcterms:abstract>
<dcterms:abstract>La osteoporosis es la enfermedad ósea más común, con una morbilidad y mortalidad significativas causadas por el aumento de la fragilidad ósea y la susceptibilidad a las fracturas. La absorciometría de rayos X de energía dual (DXA, por sus siglas en inglés) es la técnica de referencia para la evaluación de la osteoporosis y del riesgo de fracturas en la columna vertebral. Sin embargo, el análisis estándar de las imágenes DXA solo proporciona mediciones 2D y no diferencia entre los compartimentos óseos; tampoco evalúa la densidad ósea en el cuerpo vertebral, que es donde se producen la mayoría de las fracturas osteoporóticas. La tomografía computarizada cuantitativa (QCT, por sus siglas en inglés) es una técnica alternativa que supera las limitaciones del diagnóstico basado en DXA. Sin embargo, debido al alto costo y la dosis de radiación, la QCT no se usa para el diagnóstico de la osteoporosis. En esta tesis, se propone un método que proporciona una estimación personalizada de la forma 3D y la densidad de la columna vertebral en la zona lumbar a partir de una única imagen DXA anteroposterior. El método se basa en un modelo estadístico 3D de forma y densidad creado a partir de un conjunto de entrenamiento de exploraciones QCT. La estimación 3D personalizada de forma y densidad se obtiene al registrar y ajustar el modelo estadístico con la imagen DXA. Se segmentan los compartimentos óseos corticales y trabeculares utilizando un algoritmo basado en modelos. Se realizan mediciones 3D en diferentes regiones vertebrales y compartimentos óseos. La precisión de los métodos propuestos se evalúa comparando las mediciones 3D derivadas de DXA con las derivadas de QCT. También se realizan dos estudios de casos y controles: un estudio retrospectivo que evalúa la capacidad de las mediciones 3D derivadas de DXA en la columna lumbar para discriminar entre sujetos con fracturas vertebrales relacionadas con la osteoporosis y sujetos control; y un estudio que evalúa la asociación entre las mediciones 3D derivadas de DXA en la columna lumbar y las fracturas de cadera relacionadas con la osteoporosis. En ambos estudios, se encuentran asociaciones más fuertes entre las fracturas relacionadas con la osteoporosis y las mediciones 3D derivadas de DXA en comparación con las mediciones estándar 2D. La tecnología desarrollada dentro de esta tesis ofrece un análisis en 3D de la columna lumbar, que podría mejorar la evaluación de la osteoporosis y el riesgo de fractura en pacientes que se sometieron a una exploración DXA estándar de la columna lumbar sin ningún examen adicional.</dcterms:abstract>
<uketdterms:institution>Universitat Pompeu Fabra</uketdterms:institution>
<dcterms:issued>2019-03-19</dcterms:issued>
<dc:type>info:eu-repo/semantics/doctoralThesis</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:language type="dcterms:ISO639-2">eng</dc:language>
<dcterms:isReferencedBy>http://hdl.handle.net/10803/666513</dcterms:isReferencedBy>
<dcterms:hasFormat>https://www.tdx.cat/bitstream/10803/666513/3/tmlp.pdf.txt</dcterms:hasFormat>
<uketdterms:checksum type="uketdterms:MD5">e4aa3581d440a3be918bc4e4dbe166e9</uketdterms:checksum>
<dc:identifier type="dcterms:URI">https://www.tdx.cat/bitstream/10803/666513/1/tmlp.pdf</dc:identifier>
<uketdterms:checksum type="uketdterms:MD5">87d358c1ea74cb8166523e56982039a4</uketdterms:checksum>
<uketdterms:embargodate>12 mesos</uketdterms:embargodate>
<dc:subject>3D modeling</dc:subject>
<dc:subject>Statistical shape model</dc:subject>
<dc:subject>Statistical appearance model</dc:subject>
<dc:subject>Image registration</dc:subject>
<dc:subject>Lumbar spine</dc:subject>
<dc:subject>Vertebra</dc:subject>
<dc:subject>Osteoporosis</dc:subject>
<dc:subject>Volumetric bone mineral density</dc:subject>
<dc:subject>Cortical bone</dc:subject>
<dc:subject>Trabecular bone</dc:subject>
<dc:subject>Fracture risk</dc:subject>
</uketd_dc:uketddc>
<?xml version="1.0" encoding="UTF-8" ?>
<metadata schemaLocation="http://www.lyncode.com/xoai http://www.lyncode.com/xsd/xoai.xsd">
<element name="dc">
<element name="contributor">
<element name="none">
<field name="value">Universitat Pompeu Fabra. Departament de Tecnologies de la Informació i les Comunicacions</field>
</element>
<element name="author">
<element name="none">
<field name="value">López Picazo, Mirella</field>
<field name="authority">d7121cf4-6f8f-4fc5-ae26-0280d666eb8f</field>
<field name="confidence">-1</field>
</element>
</element>
<element name="authoremail">
<element name="en_US">
<field name="value">mirella.lopez01@estudiant.upf.edu</field>
</element>
</element>
<element name="authoremailshow">
<element name="en_US">
<field name="value">true</field>
</element>
</element>
<element name="director">
<element name="none">
<field name="value">González Ballester, Miguel Ángel</field>
<field name="authority">78c25316-230f-4068-a273-f8eb8f116772</field>
<field name="confidence">-1</field>
<field name="value">Humbert, Ludovic</field>
<field name="authority">0f121804-7de0-40f0-b1d8-a3d2926b5978</field>
<field name="confidence">-1</field>
</element>
</element>
</element>
<element name="date">
<element name="accessioned">
<element name="none">
<field name="value">2019-03-27T11:57:12Z</field>
</element>
</element>
<element name="available">
<element name="none">
<field name="value">2020-03-18T01:00:12Z</field>
</element>
</element>
<element name="issued">
<element name="none">
<field name="value">2019-03-19</field>
</element>
</element>
</element>
<element name="identifier">
<element name="uri">
<element name="none">
<field name="value">http://hdl.handle.net/10803/666513</field>
</element>
</element>
</element>
<element name="description">
<element name="abstract">
<element name="en_US">
<field name="value">Osteoporosis is the most common bone disease, with a significant morbidity and mortality caused by the increase of bone fragility and susceptibility to fracture. Dual Energy X-ray Absorptiometry (DXA) is the gold standard technique for osteoporosis and fracture risk evaluation at the spine. However, the standard analysis of DXA images only provides 2D measurements and does not differentiate between bone compartments; neither specifically assess bone density in the vertebral body, which is where most of the osteoporotic fractures occur. Quantitative Computed Tomography (QCT) is an alternative technique that overcomes limitations of DXA-based diagnosis. However, due to the high cost and radiation dose, QCT is not used for osteoporosis management. In this thesis, a method providing a 3D subject-specific shape and density estimation of the lumbar spine from a single anteroposterior DXA image is proposed. The method is based on a 3D statistical shape and density model built from a training set of QCT scans. The 3D subject-specific shape and density estimation is obtained by registering and fitting the statistical model onto the DXA image. Cortical and trabecular bone compartments are segmented using a model-based algorithm. 3D measurements are performed at different vertebral regions and bone compartments. The accuracy of the proposed methods is evaluated by comparing DXA-derived to QCT-derived 3D measurements. Two case-control studies are also performed: a retrospective study evaluating the ability of DXA-derived 3D measurements at lumbar spine to discriminate between osteoporosis-related vertebral fractures and control groups; and a study evaluating the association between DXA-derived 3D measurements at lumbar spine and osteoporosis-related hip fractures. In both studies, stronger associations are found between osteoporosis-related fractures and DXA-derived 3D measurements compared to standard 2D measurements. The technology developed within this thesis offers an insightful 3D analysis of the lumbar spine, which could potentially improve osteoporosis and fracture risk assessment in patients who had a standard DXA scan of the lumbar spine without any additional examination.</field>
<field name="value">La osteoporosis es la enfermedad ósea más común, con una morbilidad y mortalidad significativas causadas por el aumento de la fragilidad ósea y la susceptibilidad a las fracturas. La absorciometría de rayos X de energía dual (DXA, por sus siglas en inglés) es la técnica de referencia para la evaluación de la osteoporosis y del riesgo de fracturas en la columna vertebral. Sin embargo, el análisis estándar de las imágenes DXA solo proporciona mediciones 2D y no diferencia entre los compartimentos óseos; tampoco evalúa la densidad ósea en el cuerpo vertebral, que es donde se producen la mayoría de las fracturas osteoporóticas. La tomografía computarizada cuantitativa (QCT, por sus siglas en inglés) es una técnica alternativa que supera las limitaciones del diagnóstico basado en DXA. Sin embargo, debido al alto costo y la dosis de radiación, la QCT no se usa para el diagnóstico de la osteoporosis. En esta tesis, se propone un método que proporciona una estimación personalizada de la forma 3D y la densidad de la columna vertebral en la zona lumbar a partir de una única imagen DXA anteroposterior. El método se basa en un modelo estadístico 3D de forma y densidad creado a partir de un conjunto de entrenamiento de exploraciones QCT. La estimación 3D personalizada de forma y densidad se obtiene al registrar y ajustar el modelo estadístico con la imagen DXA. Se segmentan los compartimentos óseos corticales y trabeculares utilizando un algoritmo basado en modelos. Se realizan mediciones 3D en diferentes regiones vertebrales y compartimentos óseos. La precisión de los métodos propuestos se evalúa comparando las mediciones 3D derivadas de DXA con las derivadas de QCT. También se realizan dos estudios de casos y controles: un estudio retrospectivo que evalúa la capacidad de las mediciones 3D derivadas de DXA en la columna lumbar para discriminar entre sujetos con fracturas vertebrales relacionadas con la osteoporosis y sujetos control; y un estudio que evalúa la asociación entre las mediciones 3D derivadas de DXA en la columna lumbar y las fracturas de cadera relacionadas con la osteoporosis. En ambos estudios, se encuentran asociaciones más fuertes entre las fracturas relacionadas con la osteoporosis y las mediciones 3D derivadas de DXA en comparación con las mediciones estándar 2D. La tecnología desarrollada dentro de esta tesis ofrece un análisis en 3D de la columna lumbar, que podría mejorar la evaluación de la osteoporosis y el riesgo de fractura en pacientes que se sometieron a una exploración DXA estándar de la columna lumbar sin ningún examen adicional.</field>
</element>
</element>
<element name="degree">
<element name="none">
<field name="value">Programa de doctorat en Tecnologies de la Informació i les Comunicacions</field>
</element>
</element>
</element>
<element name="format">
<element name="extent">
<element name="en_US">
<field name="value">182 p.</field>
</element>
</element>
<element name="mimetype">
<element name="none">
<field name="value">application/pdf</field>
</element>
</element>
</element>
<element name="language">
<element name="iso">
<element name="en_US">
<field name="value">eng</field>
</element>
</element>
</element>
<element name="publisher">
<element name="none">
<field name="value">Universitat Pompeu Fabra</field>
</element>
</element>
<element name="rights">
<element name="license">
<element name="none">
<field name="value">ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.</field>
</element>
</element>
<element name="accessLevel">
<element name="none">
<field name="value">info:eu-repo/semantics/openAccess</field>
</element>
</element>
</element>
<element name="source">
<element name="none">
<field name="value">TDX (Tesis Doctorals en Xarxa)</field>
</element>
</element>
<element name="subject">
<element name="en_US">
<field name="value">3D modeling</field>
<field name="value">Statistical shape model</field>
<field name="value">Statistical appearance model</field>
<field name="value">Image registration</field>
<field name="value">Lumbar spine</field>
<field name="value">Vertebra</field>
<field name="value">Osteoporosis</field>
<field name="value">Volumetric bone mineral density</field>
<field name="value">Cortical bone</field>
<field name="value">Trabecular bone</field>
<field name="value">Fracture risk</field>
</element>
<element name="udc">
<element name="en_US">
<field name="value">62</field>
</element>
</element>
</element>
<element name="title">
<element name="en_US">
<field name="value">3D subject-specific shape and density modeling of the lumbar spine from 2D DXA images for osteoporosis assessment</field>
</element>
</element>
<element name="type">
<element name="none">
<field name="value">info:eu-repo/semantics/doctoralThesis</field>
<field name="value">info:eu-repo/semantics/publishedVersion</field>
</element>
</element>
<element name="embargo">
<element name="terms">
<element name="en_US">
<field name="value">12 mesos</field>
</element>
</element>
</element>
</element>
<element name="bundles">
<element name="bundle">
<field name="name">TEXT</field>
<element name="bitstreams">
<element name="bitstream">
<field name="name">tmlp.pdf.txt</field>
<field name="originalName">tmlp.pdf.txt</field>
<field name="description">Extracted text</field>
<field name="format">text/plain</field>
<field name="size">302312</field>
<field name="url">https://www.tdx.cat/bitstream/10803/666513/3/tmlp.pdf.txt</field>
<field name="checksum">e4aa3581d440a3be918bc4e4dbe166e9</field>
<field name="checksumAlgorithm">MD5</field>
<field name="sid">3</field>
<field name="drm">open access</field>
</element>
</element>
</element>
<element name="bundle">
<field name="name">ORIGINAL</field>
<element name="bitstreams">
<element name="bitstream">
<field name="name">tmlp.pdf</field>
<field name="originalName">tmlp.pdf</field>
<field name="format">application/pdf</field>
<field name="size">3358998</field>
<field name="url">https://www.tdx.cat/bitstream/10803/666513/1/tmlp.pdf</field>
<field name="checksum">87d358c1ea74cb8166523e56982039a4</field>
<field name="checksumAlgorithm">MD5</field>
<field name="sid">1</field>
<field name="drm">open access</field>
</element>
</element>
</element>
<element name="bundle">
<field name="name">MEDIA_DOCUMENT</field>
<element name="bitstreams">
<element name="bitstream">
<field name="name">tmlp.pdf.xml</field>
<field name="originalName">tmlp.pdf.xml</field>
<field name="description">Document Consulta</field>
<field name="format">text/xml</field>
<field name="size">105</field>
<field name="url">https://www.tdx.cat/bitstream/10803/666513/2/tmlp.pdf.xml</field>
<field name="checksum">0af1e9a416cecfa5c62d7b69fbe16e18</field>
<field name="checksumAlgorithm">MD5</field>
<field name="sid">2</field>
<field name="drm">open access</field>
</element>
</element>
</element>
</element>
<element name="others">
<field name="handle">10803/666513</field>
<field name="identifier">oai:www.tdx.cat:10803/666513</field>
<field name="lastModifyDate">2024-03-15 11:58:02.563</field>
<field name="drm">open access</field>
</element>
<element name="repository">
<field name="name">TDX (Tesis Doctorals en Xarxa)</field>
<field name="mail">pir@csuc.cat</field>
</element>
</metadata>