<?xml version="1.0" encoding="UTF-8" ?>
<oai_dc:dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title>3D-printing of transparent bio-microfluidic devices in PEG-DA</dc:title>
<dc:creator>Urrios Garcia, Arturo, 1990-</dc:creator>
<dc:creator>Parra-Cabrera, Cesar</dc:creator>
<dc:creator>Bhattacharjee, Nirveek</dc:creator>
<dc:creator>Gonzalez-Suarez, Alan M.</dc:creator>
<dc:creator>Rigat-Brugarolas, Luis G.</dc:creator>
<dc:creator>Nallapatti, Umashree</dc:creator>
<dc:creator>Samitier, Josep</dc:creator>
<dc:creator>DeForest, Cole A.</dc:creator>
<dc:creator>Posas Garriga, Francesc</dc:creator>
<dc:creator>Garcia-Cordero, José L.</dc:creator>
<dc:creator>Folch, Albert</dc:creator>
<dc:subject>Microfluídica</dc:subject>
<dc:subject>Polietilenglicol</dc:subject>
<dc:subject>Disseny assistit per ordinador</dc:subject>
<dc:description>The vast majority of microfluidic systems are molded in poly(dimethylsiloxane) (PDMS) by soft lithography due to the favorable properties of PDMS: biocompatible, elastomeric, transparent, gas-permeable, inexpensive, and copyright-free. However, PDMS molding involves tedious manual labor, which makes PDMS devices prone to assembly failures and difficult to disseminate to research and clinical settings. Furthermore, the fabrication procedures limit the 3D complexity of the devices to layered designs. Stereolithography (SL), a form of 3D-printing, has recently attracted attention as a way to customize the fabrication of biomedical devices due to its automated, assembly-free 3D fabrication, rapidly decreasing costs, and fast-improving resolution and throughput. However, existing SL resins are not biocompatible and patterning transparent resins at high resolution remains difficult. Here we report procedures for the preparation and patterning of a transparent resin based on low-MW poly(ethylene glycol) diacrylate (MW 250) (PEG-DA-250). The 3D-printed devices are highly transparent and cells can be cultured on PEG-DA-250 prints for several days. This biocompatible SL resin and printing process solves some of the main drawbacks of 3D-printed microfluidic devices: biocompatibility and transparency. In addition, it should also enable the production of non-microfluidic biomedical devices.</dc:description>
<dc:description>The Ilios 3D-Printer is on loan from 3D-Skema, Inc. A. U. is a recipient of a “La Caixa” fellowship from Catalonia and an European Molecular Biology Organization (EMBO) short-term fellowship. C. P. is a recipient of a “Consejo Nacional de Ciencia y Tecnología” (CONACYT) Mexican fellowship. F. P. is supported by the Spanish Ministry of Economy and Competitiveness (BFU2015-64437-P and FEDER), the Catalan Government (2014 SGR 599) and an ERC Advanced Grant Number 294294 from the European Union seventh framework program (SYNCOM). F. P. is supported by Fundación Botín, by Banco Santander through its Santander Universities Global Division and recipient of an ICREA Acadèmia (Generalitat de Catalunya). For the cell culture data and cell microscopy, we acknowledge partial support from the National Institutes of Health, grant number 1R01NS064387-01A2</dc:description>
<dc:date>2016</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/acceptedVersion</dc:type>
<dc:identifier>Urrios A, Parra-Cabrera C, Bhattacharjee N, Gonzalez-Suarez AM, Rigat-Brugarolas LG, Nallapatti U et al. 3D-printing of transparent bio-microfluidic devices in PEG-DA. Lab Chip. 2016 Jun 21;16(12):2287-94. DOI: 10.1039/c6lc00153j</dc:identifier>
<dc:identifier>1473-0197</dc:identifier>
<dc:identifier>http://hdl.handle.net/10230/35989</dc:identifier>
<dc:identifier>http://dx.doi.org/10.1039/c6lc00153j</dc:identifier>
<dc:language>eng</dc:language>
<dc:relation>Lab on a Chip. 2016 Jun 21;16(12):2287-94</dc:relation>
<dc:relation>info:eu-repo/grantAgreement/ES/1PE/BFU2015-64437-P</dc:relation>
<dc:relation>info:eu-repo/grantAgreement/EC/FP7/294294</dc:relation>
<dc:rights>© Royal Society of Chemistry</dc:rights>
<dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
<dc:format>application/pdf</dc:format>
<dc:publisher>Royal Society of Chemistry</dc:publisher>
</oai_dc:dc>
<?xml version="1.0" encoding="UTF-8" ?>
<d:DIDL schemaLocation="urn:mpeg:mpeg21:2002:02-DIDL-NS http://standards.iso.org/ittf/PubliclyAvailableStandards/MPEG-21_schema_files/did/didl.xsd">
<d:DIDLInfo>
<dcterms:created schemaLocation="http://purl.org/dc/terms/ http://dublincore.org/schemas/xmls/qdc/dcterms.xsd">2018-12-05T08:33:13Z</dcterms:created>
</d:DIDLInfo>
<d:Item id="hdl_10230_35989">
<d:Descriptor>
<d:Statement mimeType="application/xml; charset=utf-8">
<dii:Identifier schemaLocation="urn:mpeg:mpeg21:2002:01-DII-NS http://standards.iso.org/ittf/PubliclyAvailableStandards/MPEG-21_schema_files/dii/dii.xsd">urn:hdl:10230/35989</dii:Identifier>
</d:Statement>
</d:Descriptor>
<d:Descriptor>
<d:Statement mimeType="application/xml; charset=utf-8">
<oai_dc:dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title>3D-printing of transparent bio-microfluidic devices in PEG-DA</dc:title>
<dc:creator>Urrios Garcia, Arturo, 1990-</dc:creator>
<dc:creator>Parra-Cabrera, Cesar</dc:creator>
<dc:creator>Bhattacharjee, Nirveek</dc:creator>
<dc:creator>Gonzalez-Suarez, Alan M.</dc:creator>
<dc:creator>Rigat-Brugarolas, Luis G.</dc:creator>
<dc:creator>Nallapatti, Umashree</dc:creator>
<dc:creator>Samitier, Josep</dc:creator>
<dc:creator>DeForest, Cole A.</dc:creator>
<dc:creator>Posas Garriga, Francesc</dc:creator>
<dc:creator>Garcia-Cordero, José L.</dc:creator>
<dc:creator>Folch, Albert</dc:creator>
<dc:description>The vast majority of microfluidic systems are molded in poly(dimethylsiloxane) (PDMS) by soft lithography due to the favorable properties of PDMS: biocompatible, elastomeric, transparent, gas-permeable, inexpensive, and copyright-free. However, PDMS molding involves tedious manual labor, which makes PDMS devices prone to assembly failures and difficult to disseminate to research and clinical settings. Furthermore, the fabrication procedures limit the 3D complexity of the devices to layered designs. Stereolithography (SL), a form of 3D-printing, has recently attracted attention as a way to customize the fabrication of biomedical devices due to its automated, assembly-free 3D fabrication, rapidly decreasing costs, and fast-improving resolution and throughput. However, existing SL resins are not biocompatible and patterning transparent resins at high resolution remains difficult. Here we report procedures for the preparation and patterning of a transparent resin based on low-MW poly(ethylene glycol) diacrylate (MW 250) (PEG-DA-250). The 3D-printed devices are highly transparent and cells can be cultured on PEG-DA-250 prints for several days. This biocompatible SL resin and printing process solves some of the main drawbacks of 3D-printed microfluidic devices: biocompatibility and transparency. In addition, it should also enable the production of non-microfluidic biomedical devices.</dc:description>
<dc:date>2018-12-05T08:33:13Z</dc:date>
<dc:date>2018-12-05T08:33:13Z</dc:date>
<dc:date>2016</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:identifier>Urrios A, Parra-Cabrera C, Bhattacharjee N, Gonzalez-Suarez AM, Rigat-Brugarolas LG, Nallapatti U et al. 3D-printing of transparent bio-microfluidic devices in PEG-DA. Lab Chip. 2016 Jun 21;16(12):2287-94. DOI: 10.1039/c6lc00153j</dc:identifier>
<dc:identifier>1473-0197</dc:identifier>
<dc:identifier>http://hdl.handle.net/10230/35989</dc:identifier>
<dc:identifier>http://dx.doi.org/10.1039/c6lc00153j</dc:identifier>
<dc:language>eng</dc:language>
<dc:relation>Lab on a Chip. 2016 Jun 21;16(12):2287-94</dc:relation>
<dc:relation>info:eu-repo/grantAgreement/ES/1PE/BFU2015-64437-P</dc:relation>
<dc:relation>info:eu-repo/grantAgreement/EC/FP7/294294</dc:relation>
<dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
<dc:rights>© Royal Society of Chemistry</dc:rights>
<dc:publisher>Royal Society of Chemistry</dc:publisher>
</oai_dc:dc>
</d:Statement>
</d:Descriptor>
<d:Component id="10230_35989_1">
</d:Component>
</d:Item>
</d:DIDL>
<?xml version="1.0" encoding="UTF-8" ?>
<dim:dim schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
<dim:field element="contributor" mdschema="dc" qualifier="author">Urrios Garcia, Arturo, 1990-</dim:field>
<dim:field element="contributor" mdschema="dc" qualifier="author">Parra-Cabrera, Cesar</dim:field>
<dim:field element="contributor" mdschema="dc" qualifier="author">Bhattacharjee, Nirveek</dim:field>
<dim:field element="contributor" mdschema="dc" qualifier="author">Gonzalez-Suarez, Alan M.</dim:field>
<dim:field element="contributor" mdschema="dc" qualifier="author">Rigat-Brugarolas, Luis G.</dim:field>
<dim:field element="contributor" mdschema="dc" qualifier="author">Nallapatti, Umashree</dim:field>
<dim:field element="contributor" mdschema="dc" qualifier="author">Samitier, Josep</dim:field>
<dim:field element="contributor" mdschema="dc" qualifier="author">DeForest, Cole A.</dim:field>
<dim:field element="contributor" mdschema="dc" qualifier="author">Posas Garriga, Francesc</dim:field>
<dim:field element="contributor" mdschema="dc" qualifier="author">Garcia-Cordero, José L.</dim:field>
<dim:field element="contributor" mdschema="dc" qualifier="author">Folch, Albert</dim:field>
<dim:field element="date" mdschema="dc" qualifier="accessioned">2018-12-05T08:33:13Z</dim:field>
<dim:field element="date" mdschema="dc" qualifier="available">2018-12-05T08:33:13Z</dim:field>
<dim:field element="date" mdschema="dc" qualifier="issued">2016</dim:field>
<dim:field element="identifier" mdschema="dc" qualifier="citation">Urrios A, Parra-Cabrera C, Bhattacharjee N, Gonzalez-Suarez AM, Rigat-Brugarolas LG, Nallapatti U et al. 3D-printing of transparent bio-microfluidic devices in PEG-DA. Lab Chip. 2016 Jun 21;16(12):2287-94. DOI: 10.1039/c6lc00153j</dim:field>
<dim:field element="identifier" mdschema="dc" qualifier="issn">1473-0197</dim:field>
<dim:field element="identifier" mdschema="dc" qualifier="uri">http://hdl.handle.net/10230/35989</dim:field>
<dim:field element="identifier" mdschema="dc" qualifier="doi">http://dx.doi.org/10.1039/c6lc00153j</dim:field>
<dim:field element="description" mdschema="dc" qualifier="abstract">The vast majority of microfluidic systems are molded in poly(dimethylsiloxane) (PDMS) by soft lithography due to the favorable properties of PDMS: biocompatible, elastomeric, transparent, gas-permeable, inexpensive, and copyright-free. However, PDMS molding involves tedious manual labor, which makes PDMS devices prone to assembly failures and difficult to disseminate to research and clinical settings. Furthermore, the fabrication procedures limit the 3D complexity of the devices to layered designs. Stereolithography (SL), a form of 3D-printing, has recently attracted attention as a way to customize the fabrication of biomedical devices due to its automated, assembly-free 3D fabrication, rapidly decreasing costs, and fast-improving resolution and throughput. However, existing SL resins are not biocompatible and patterning transparent resins at high resolution remains difficult. Here we report procedures for the preparation and patterning of a transparent resin based on low-MW poly(ethylene glycol) diacrylate (MW 250) (PEG-DA-250). The 3D-printed devices are highly transparent and cells can be cultured on PEG-DA-250 prints for several days. This biocompatible SL resin and printing process solves some of the main drawbacks of 3D-printed microfluidic devices: biocompatibility and transparency. In addition, it should also enable the production of non-microfluidic biomedical devices.</dim:field>
<dim:field element="description" lang="en" mdschema="dc" qualifier="provenance">Made available in DSpace on 2018-12-05T08:33:13Z (GMT). No. of bitstreams: 1 Urr_LC_3D.pdf: 896437 bytes, checksum: 1d0051dc7909840b227c2b0b4f68f22a (MD5) Previous issue date: 2016</dim:field>
<dim:field element="description" mdschema="dc" qualifier="sponsorship">The Ilios 3D-Printer is on loan from 3D-Skema, Inc. A. U. is a recipient of a “La Caixa” fellowship from Catalonia and an European Molecular Biology Organization (EMBO) short-term fellowship. C. P. is a recipient of a “Consejo Nacional de Ciencia y Tecnología” (CONACYT) Mexican fellowship. F. P. is supported by the Spanish Ministry of Economy and Competitiveness (BFU2015-64437-P and FEDER), the Catalan Government (2014 SGR 599) and an ERC Advanced Grant Number 294294 from the European Union seventh framework program (SYNCOM). F. P. is supported by Fundación Botín, by Banco Santander through its Santander Universities Global Division and recipient of an ICREA Acadèmia (Generalitat de Catalunya). For the cell culture data and cell microscopy, we acknowledge partial support from the National Institutes of Health, grant number 1R01NS064387-01A2</dim:field>
<dim:field element="format" mdschema="dc" qualifier="mimetype">application/pdf</dim:field>
<dim:field element="language" mdschema="dc" qualifier="iso">eng</dim:field>
<dim:field element="publisher" mdschema="dc">Royal Society of Chemistry</dim:field>
<dim:field element="relation" mdschema="dc" qualifier="ispartof">Lab on a Chip. 2016 Jun 21;16(12):2287-94</dim:field>
<dim:field element="relation" mdschema="dc" qualifier="projectID">info:eu-repo/grantAgreement/ES/1PE/BFU2015-64437-P</dim:field>
<dim:field element="relation" mdschema="dc" qualifier="projectID">info:eu-repo/grantAgreement/EC/FP7/294294</dim:field>
<dim:field element="rights" mdschema="dc">© Royal Society of Chemistry</dim:field>
<dim:field element="rights" mdschema="dc" qualifier="accessRights">info:eu-repo/semantics/openAccess</dim:field>
<dim:field element="subject" mdschema="dc" qualifier="other">Microfluídica</dim:field>
<dim:field element="subject" mdschema="dc" qualifier="other">Polietilenglicol</dim:field>
<dim:field element="subject" mdschema="dc" qualifier="other">Disseny assistit per ordinador</dim:field>
<dim:field element="title" mdschema="dc">3D-printing of transparent bio-microfluidic devices in PEG-DA</dim:field>
<dim:field element="type" mdschema="dc">info:eu-repo/semantics/article</dim:field>
<dim:field element="type" mdschema="dc" qualifier="version">info:eu-repo/semantics/acceptedVersion</dim:field>
</dim:dim>
<?xml version="1.0" encoding="UTF-8" ?>
<thesis schemaLocation="http://www.ndltd.org/standards/metadata/etdms/1.0/ http://www.ndltd.org/standards/metadata/etdms/1.0/etdms.xsd">
<title>3D-printing of transparent bio-microfluidic devices in PEG-DA</title>
<creator>Urrios Garcia, Arturo, 1990-</creator>
<creator>Parra-Cabrera, Cesar</creator>
<creator>Bhattacharjee, Nirveek</creator>
<creator>Gonzalez-Suarez, Alan M.</creator>
<creator>Rigat-Brugarolas, Luis G.</creator>
<creator>Nallapatti, Umashree</creator>
<creator>Samitier, Josep</creator>
<creator>DeForest, Cole A.</creator>
<creator>Posas Garriga, Francesc</creator>
<creator>Garcia-Cordero, José L.</creator>
<creator>Folch, Albert</creator>
<description>The vast majority of microfluidic systems are molded in poly(dimethylsiloxane) (PDMS) by soft lithography due to the favorable properties of PDMS: biocompatible, elastomeric, transparent, gas-permeable, inexpensive, and copyright-free. However, PDMS molding involves tedious manual labor, which makes PDMS devices prone to assembly failures and difficult to disseminate to research and clinical settings. Furthermore, the fabrication procedures limit the 3D complexity of the devices to layered designs. Stereolithography (SL), a form of 3D-printing, has recently attracted attention as a way to customize the fabrication of biomedical devices due to its automated, assembly-free 3D fabrication, rapidly decreasing costs, and fast-improving resolution and throughput. However, existing SL resins are not biocompatible and patterning transparent resins at high resolution remains difficult. Here we report procedures for the preparation and patterning of a transparent resin based on low-MW poly(ethylene glycol) diacrylate (MW 250) (PEG-DA-250). The 3D-printed devices are highly transparent and cells can be cultured on PEG-DA-250 prints for several days. This biocompatible SL resin and printing process solves some of the main drawbacks of 3D-printed microfluidic devices: biocompatibility and transparency. In addition, it should also enable the production of non-microfluidic biomedical devices.</description>
<date>2018-12-05</date>
<date>2018-12-05</date>
<date>2016</date>
<type>info:eu-repo/semantics/article</type>
<identifier>Urrios A, Parra-Cabrera C, Bhattacharjee N, Gonzalez-Suarez AM, Rigat-Brugarolas LG, Nallapatti U et al. 3D-printing of transparent bio-microfluidic devices in PEG-DA. Lab Chip. 2016 Jun 21;16(12):2287-94. DOI: 10.1039/c6lc00153j</identifier>
<identifier>1473-0197</identifier>
<identifier>http://hdl.handle.net/10230/35989</identifier>
<identifier>http://dx.doi.org/10.1039/c6lc00153j</identifier>
<language>eng</language>
<relation>Lab on a Chip. 2016 Jun 21;16(12):2287-94</relation>
<relation>info:eu-repo/grantAgreement/ES/1PE/BFU2015-64437-P</relation>
<relation>info:eu-repo/grantAgreement/EC/FP7/294294</relation>
<rights>info:eu-repo/semantics/openAccess</rights>
<rights>© Royal Society of Chemistry</rights>
<publisher>Royal Society of Chemistry</publisher>
</thesis>
<?xml version="1.0" encoding="UTF-8" ?>
<record schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<leader>00925njm 22002777a 4500</leader>
<datafield ind1=" " ind2=" " tag="042">
<subfield code="a">dc</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="720">
<subfield code="a">Urrios Garcia, Arturo, 1990-</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="720">
<subfield code="a">Parra-Cabrera, Cesar</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="720">
<subfield code="a">Bhattacharjee, Nirveek</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="720">
<subfield code="a">Gonzalez-Suarez, Alan M.</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="720">
<subfield code="a">Rigat-Brugarolas, Luis G.</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="720">
<subfield code="a">Nallapatti, Umashree</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="720">
<subfield code="a">Samitier, Josep</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="720">
<subfield code="a">DeForest, Cole A.</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="720">
<subfield code="a">Posas Garriga, Francesc</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="720">
<subfield code="a">Garcia-Cordero, José L.</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="720">
<subfield code="a">Folch, Albert</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="260">
<subfield code="c">2016</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="520">
<subfield code="a">The vast majority of microfluidic systems are molded in poly(dimethylsiloxane) (PDMS) by soft lithography due to the favorable properties of PDMS: biocompatible, elastomeric, transparent, gas-permeable, inexpensive, and copyright-free. However, PDMS molding involves tedious manual labor, which makes PDMS devices prone to assembly failures and difficult to disseminate to research and clinical settings. Furthermore, the fabrication procedures limit the 3D complexity of the devices to layered designs. Stereolithography (SL), a form of 3D-printing, has recently attracted attention as a way to customize the fabrication of biomedical devices due to its automated, assembly-free 3D fabrication, rapidly decreasing costs, and fast-improving resolution and throughput. However, existing SL resins are not biocompatible and patterning transparent resins at high resolution remains difficult. Here we report procedures for the preparation and patterning of a transparent resin based on low-MW poly(ethylene glycol) diacrylate (MW 250) (PEG-DA-250). The 3D-printed devices are highly transparent and cells can be cultured on PEG-DA-250 prints for several days. This biocompatible SL resin and printing process solves some of the main drawbacks of 3D-printed microfluidic devices: biocompatibility and transparency. In addition, it should also enable the production of non-microfluidic biomedical devices.</subfield>
</datafield>
<datafield ind1="8" ind2=" " tag="024">
<subfield code="a">Urrios A, Parra-Cabrera C, Bhattacharjee N, Gonzalez-Suarez AM, Rigat-Brugarolas LG, Nallapatti U et al. 3D-printing of transparent bio-microfluidic devices in PEG-DA. Lab Chip. 2016 Jun 21;16(12):2287-94. DOI: 10.1039/c6lc00153j</subfield>
</datafield>
<datafield ind1="8" ind2=" " tag="024">
<subfield code="a">1473-0197</subfield>
</datafield>
<datafield ind1="8" ind2=" " tag="024">
<subfield code="a">http://hdl.handle.net/10230/35989</subfield>
</datafield>
<datafield ind1="8" ind2=" " tag="024">
<subfield code="a">http://dx.doi.org/10.1039/c6lc00153j</subfield>
</datafield>
<datafield ind1="0" ind2="0" tag="245">
<subfield code="a">3D-printing of transparent bio-microfluidic devices in PEG-DA</subfield>
</datafield>
</record>
<?xml version="1.0" encoding="UTF-8" ?>
<mets ID=" DSpace_ITEM_10230-35989" OBJID=" hdl:10230/35989" PROFILE="DSpace METS SIP Profile 1.0" TYPE="DSpace ITEM" schemaLocation="http://www.loc.gov/METS/ http://www.loc.gov/standards/mets/mets.xsd">
<metsHdr CREATEDATE="2022-08-26T09:40:26Z">
<agent ROLE="CUSTODIAN" TYPE="ORGANIZATION">
<name>Repositori digital de la UPF</name>
</agent>
</metsHdr>
<dmdSec ID="DMD_10230_35989">
<mdWrap MDTYPE="MODS">
<xmlData schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
<mods:mods schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
<mods:name>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
<mods:namePart>Urrios Garcia, Arturo, 1990-</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
<mods:namePart>Parra-Cabrera, Cesar</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
<mods:namePart>Bhattacharjee, Nirveek</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
<mods:namePart>Gonzalez-Suarez, Alan M.</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
<mods:namePart>Rigat-Brugarolas, Luis G.</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
<mods:namePart>Nallapatti, Umashree</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
<mods:namePart>Samitier, Josep</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
<mods:namePart>DeForest, Cole A.</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
<mods:namePart>Posas Garriga, Francesc</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
<mods:namePart>Garcia-Cordero, José L.</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
<mods:namePart>Folch, Albert</mods:namePart>
</mods:name>
<mods:extension>
<mods:dateAccessioned encoding="iso8601">2018-12-05T08:33:13Z</mods:dateAccessioned>
</mods:extension>
<mods:extension>
<mods:dateAvailable encoding="iso8601">2018-12-05T08:33:13Z</mods:dateAvailable>
</mods:extension>
<mods:originInfo>
<mods:dateIssued encoding="iso8601">2016</mods:dateIssued>
</mods:originInfo>
<mods:identifier type="citation">Urrios A, Parra-Cabrera C, Bhattacharjee N, Gonzalez-Suarez AM, Rigat-Brugarolas LG, Nallapatti U et al. 3D-printing of transparent bio-microfluidic devices in PEG-DA. Lab Chip. 2016 Jun 21;16(12):2287-94. DOI: 10.1039/c6lc00153j</mods:identifier>
<mods:identifier type="issn">1473-0197</mods:identifier>
<mods:identifier type="uri">http://hdl.handle.net/10230/35989</mods:identifier>
<mods:identifier type="doi">http://dx.doi.org/10.1039/c6lc00153j</mods:identifier>
<mods:abstract>The vast majority of microfluidic systems are molded in poly(dimethylsiloxane) (PDMS) by soft lithography due to the favorable properties of PDMS: biocompatible, elastomeric, transparent, gas-permeable, inexpensive, and copyright-free. However, PDMS molding involves tedious manual labor, which makes PDMS devices prone to assembly failures and difficult to disseminate to research and clinical settings. Furthermore, the fabrication procedures limit the 3D complexity of the devices to layered designs. Stereolithography (SL), a form of 3D-printing, has recently attracted attention as a way to customize the fabrication of biomedical devices due to its automated, assembly-free 3D fabrication, rapidly decreasing costs, and fast-improving resolution and throughput. However, existing SL resins are not biocompatible and patterning transparent resins at high resolution remains difficult. Here we report procedures for the preparation and patterning of a transparent resin based on low-MW poly(ethylene glycol) diacrylate (MW 250) (PEG-DA-250). The 3D-printed devices are highly transparent and cells can be cultured on PEG-DA-250 prints for several days. This biocompatible SL resin and printing process solves some of the main drawbacks of 3D-printed microfluidic devices: biocompatibility and transparency. In addition, it should also enable the production of non-microfluidic biomedical devices.</mods:abstract>
<mods:language>
<mods:languageTerm authority="rfc3066">eng</mods:languageTerm>
</mods:language>
<mods:accessCondition type="useAndReproduction">© Royal Society of Chemistry</mods:accessCondition>
<mods:titleInfo>
<mods:title>3D-printing of transparent bio-microfluidic devices in PEG-DA</mods:title>
</mods:titleInfo>
<mods:genre>info:eu-repo/semantics/article</mods:genre>
</mods:mods>
</xmlData>
</mdWrap>
</dmdSec>
<amdSec ID="FO_10230_35989_1">
<techMD ID="TECH_O_10230_35989_1">
<mdWrap MDTYPE="PREMIS">
<xmlData schemaLocation="http://www.loc.gov/standards/premis http://www.loc.gov/standards/premis/PREMIS-v1-0.xsd">
<premis:premis>
<premis:object>
<premis:objectIdentifier>
<premis:objectIdentifierType>URL</premis:objectIdentifierType>
<premis:objectIdentifierValue>http://repositori.upf.edu/bitstream/10230/35989/1/Urr_LC_3D.pdf</premis:objectIdentifierValue>
</premis:objectIdentifier>
<premis:objectCategory>File</premis:objectCategory>
<premis:objectCharacteristics>
<premis:fixity>
<premis:messageDigestAlgorithm>MD5</premis:messageDigestAlgorithm>
<premis:messageDigest>1d0051dc7909840b227c2b0b4f68f22a</premis:messageDigest>
</premis:fixity>
<premis:size>896437</premis:size>
<premis:format>
<premis:formatDesignation>
<premis:formatName>application/pdf</premis:formatName>
</premis:formatDesignation>
</premis:format>
</premis:objectCharacteristics>
<premis:originalName>Urr_LC_3D.pdf</premis:originalName>
</premis:object>
</premis:premis>
</xmlData>
</mdWrap>
</techMD>
</amdSec>
<amdSec ID="FT_10230_35989_2">
<techMD ID="TECH_T_10230_35989_2">
<mdWrap MDTYPE="PREMIS">
<xmlData schemaLocation="http://www.loc.gov/standards/premis http://www.loc.gov/standards/premis/PREMIS-v1-0.xsd">
<premis:premis>
<premis:object>
<premis:objectIdentifier>
<premis:objectIdentifierType>URL</premis:objectIdentifierType>
<premis:objectIdentifierValue>http://repositori.upf.edu/bitstream/10230/35989/2/Urr_LC_3D.pdf.txt</premis:objectIdentifierValue>
</premis:objectIdentifier>
<premis:objectCategory>File</premis:objectCategory>
<premis:objectCharacteristics>
<premis:fixity>
<premis:messageDigestAlgorithm>MD5</premis:messageDigestAlgorithm>
<premis:messageDigest>339d74a69157fe630676a70f55813549</premis:messageDigest>
</premis:fixity>
<premis:size>38283</premis:size>
<premis:format>
<premis:formatDesignation>
<premis:formatName>text/plain</premis:formatName>
</premis:formatDesignation>
</premis:format>
</premis:objectCharacteristics>
<premis:originalName>Urr_LC_3D.pdf.txt</premis:originalName>
</premis:object>
</premis:premis>
</xmlData>
</mdWrap>
</techMD>
</amdSec>
<fileSec>
<fileGrp USE="ORIGINAL">
<file ADMID="FO_10230_35989_1" CHECKSUM="1d0051dc7909840b227c2b0b4f68f22a" CHECKSUMTYPE="MD5" GROUPID="GROUP_BITSTREAM_10230_35989_1" ID="BITSTREAM_ORIGINAL_10230_35989_1" MIMETYPE="application/pdf" SEQ="1" SIZE="896437">
</file>
</fileGrp>
<fileGrp USE="TEXT">
<file ADMID="FT_10230_35989_2" CHECKSUM="339d74a69157fe630676a70f55813549" CHECKSUMTYPE="MD5" GROUPID="GROUP_BITSTREAM_10230_35989_2" ID="BITSTREAM_TEXT_10230_35989_2" MIMETYPE="text/plain" SEQ="2" SIZE="38283">
</file>
</fileGrp>
</fileSec>
<structMap LABEL="DSpace Object" TYPE="LOGICAL">
<div ADMID="DMD_10230_35989" TYPE="DSpace Object Contents">
<div TYPE="DSpace BITSTREAM">
</div>
</div>
</structMap>
</mets>
<?xml version="1.0" encoding="UTF-8" ?>
<mods:mods schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
<mods:name>
<mods:namePart>Urrios Garcia, Arturo, 1990-</mods:namePart>
</mods:name>
<mods:name>
<mods:namePart>Parra-Cabrera, Cesar</mods:namePart>
</mods:name>
<mods:name>
<mods:namePart>Bhattacharjee, Nirveek</mods:namePart>
</mods:name>
<mods:name>
<mods:namePart>Gonzalez-Suarez, Alan M.</mods:namePart>
</mods:name>
<mods:name>
<mods:namePart>Rigat-Brugarolas, Luis G.</mods:namePart>
</mods:name>
<mods:name>
<mods:namePart>Nallapatti, Umashree</mods:namePart>
</mods:name>
<mods:name>
<mods:namePart>Samitier, Josep</mods:namePart>
</mods:name>
<mods:name>
<mods:namePart>DeForest, Cole A.</mods:namePart>
</mods:name>
<mods:name>
<mods:namePart>Posas Garriga, Francesc</mods:namePart>
</mods:name>
<mods:name>
<mods:namePart>Garcia-Cordero, José L.</mods:namePart>
</mods:name>
<mods:name>
<mods:namePart>Folch, Albert</mods:namePart>
</mods:name>
<mods:extension>
<mods:dateAvailable encoding="iso8601">2018-12-05T08:33:13Z</mods:dateAvailable>
</mods:extension>
<mods:extension>
<mods:dateAccessioned encoding="iso8601">2018-12-05T08:33:13Z</mods:dateAccessioned>
</mods:extension>
<mods:originInfo>
<mods:dateIssued encoding="iso8601">2016</mods:dateIssued>
</mods:originInfo>
<mods:identifier type="citation">Urrios A, Parra-Cabrera C, Bhattacharjee N, Gonzalez-Suarez AM, Rigat-Brugarolas LG, Nallapatti U et al. 3D-printing of transparent bio-microfluidic devices in PEG-DA. Lab Chip. 2016 Jun 21;16(12):2287-94. DOI: 10.1039/c6lc00153j</mods:identifier>
<mods:identifier type="issn">1473-0197</mods:identifier>
<mods:identifier type="uri">http://hdl.handle.net/10230/35989</mods:identifier>
<mods:identifier type="doi">http://dx.doi.org/10.1039/c6lc00153j</mods:identifier>
<mods:abstract>The vast majority of microfluidic systems are molded in poly(dimethylsiloxane) (PDMS) by soft lithography due to the favorable properties of PDMS: biocompatible, elastomeric, transparent, gas-permeable, inexpensive, and copyright-free. However, PDMS molding involves tedious manual labor, which makes PDMS devices prone to assembly failures and difficult to disseminate to research and clinical settings. Furthermore, the fabrication procedures limit the 3D complexity of the devices to layered designs. Stereolithography (SL), a form of 3D-printing, has recently attracted attention as a way to customize the fabrication of biomedical devices due to its automated, assembly-free 3D fabrication, rapidly decreasing costs, and fast-improving resolution and throughput. However, existing SL resins are not biocompatible and patterning transparent resins at high resolution remains difficult. Here we report procedures for the preparation and patterning of a transparent resin based on low-MW poly(ethylene glycol) diacrylate (MW 250) (PEG-DA-250). The 3D-printed devices are highly transparent and cells can be cultured on PEG-DA-250 prints for several days. This biocompatible SL resin and printing process solves some of the main drawbacks of 3D-printed microfluidic devices: biocompatibility and transparency. In addition, it should also enable the production of non-microfluidic biomedical devices.</mods:abstract>
<mods:language>
<mods:languageTerm>eng</mods:languageTerm>
</mods:language>
<mods:accessCondition type="useAndReproduction">info:eu-repo/semantics/openAccess</mods:accessCondition>
<mods:accessCondition type="useAndReproduction">© Royal Society of Chemistry</mods:accessCondition>
<mods:titleInfo>
<mods:title>3D-printing of transparent bio-microfluidic devices in PEG-DA</mods:title>
</mods:titleInfo>
<mods:genre>info:eu-repo/semantics/article</mods:genre>
</mods:mods>
<?xml version="1.0" encoding="UTF-8" ?>
<atom:entry schemaLocation="http://www.w3.org/2005/Atom http://www.kbcafe.com/rss/atom.xsd.xml">
<atom:id>http://oai-repositori.upf.edu/oai/metadata/handle/10230/35989/ore.xml</atom:id>
<atom:published>2018-12-05T08:33:13Z</atom:published>
<atom:updated>2018-12-05T08:33:13Z</atom:updated>
<atom:source>
<atom:generator>Repositori digital de la UPF</atom:generator>
</atom:source>
<atom:title>3D-printing of transparent bio-microfluidic devices in PEG-DA</atom:title>
<atom:author>
<atom:name>Urrios Garcia, Arturo, 1990-</atom:name>
</atom:author>
<atom:author>
<atom:name>Parra-Cabrera, Cesar</atom:name>
</atom:author>
<atom:author>
<atom:name>Bhattacharjee, Nirveek</atom:name>
</atom:author>
<atom:author>
<atom:name>Gonzalez-Suarez, Alan M.</atom:name>
</atom:author>
<atom:author>
<atom:name>Rigat-Brugarolas, Luis G.</atom:name>
</atom:author>
<atom:author>
<atom:name>Nallapatti, Umashree</atom:name>
</atom:author>
<atom:author>
<atom:name>Samitier, Josep</atom:name>
</atom:author>
<atom:author>
<atom:name>DeForest, Cole A.</atom:name>
</atom:author>
<atom:author>
<atom:name>Posas Garriga, Francesc</atom:name>
</atom:author>
<atom:author>
<atom:name>Garcia-Cordero, José L.</atom:name>
</atom:author>
<atom:author>
<atom:name>Folch, Albert</atom:name>
</atom:author>
<oreatom:triples>
<rdf:Description about="http://oai-repositori.upf.edu/oai/metadata/handle/10230/35989/ore.xml#atom">
<dcterms:modified>2018-12-05T08:33:13Z</dcterms:modified>
</rdf:Description>
<rdf:Description about="http://repositori.upf.edu/bitstream/10230/35989/3/Urr_LC_3D.pdf.jpg">
<dcterms:description>THUMBNAIL</dcterms:description>
</rdf:Description>
<rdf:Description about="http://repositori.upf.edu/bitstream/10230/35989/2/Urr_LC_3D.pdf.txt">
<dcterms:description>TEXT</dcterms:description>
</rdf:Description>
<rdf:Description about="http://repositori.upf.edu/bitstream/10230/35989/1/Urr_LC_3D.pdf">
<dcterms:description>ORIGINAL</dcterms:description>
</rdf:Description>
</oreatom:triples>
</atom:entry>
<?xml version="1.0" encoding="UTF-8" ?>
<qdc:qualifieddc schemaLocation="http://purl.org/dc/elements/1.1/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dc.xsd http://purl.org/dc/terms/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dcterms.xsd http://dspace.org/qualifieddc/ http://www.ukoln.ac.uk/metadata/dcmi/xmlschema/qualifieddc.xsd">
<dc:title>3D-printing of transparent bio-microfluidic devices in PEG-DA</dc:title>
<dc:creator>Urrios Garcia, Arturo, 1990-</dc:creator>
<dc:creator>Parra-Cabrera, Cesar</dc:creator>
<dc:creator>Bhattacharjee, Nirveek</dc:creator>
<dc:creator>Gonzalez-Suarez, Alan M.</dc:creator>
<dc:creator>Rigat-Brugarolas, Luis G.</dc:creator>
<dc:creator>Nallapatti, Umashree</dc:creator>
<dc:creator>Samitier, Josep</dc:creator>
<dc:creator>DeForest, Cole A.</dc:creator>
<dc:creator>Posas Garriga, Francesc</dc:creator>
<dc:creator>Garcia-Cordero, José L.</dc:creator>
<dc:creator>Folch, Albert</dc:creator>
<dcterms:abstract>The vast majority of microfluidic systems are molded in poly(dimethylsiloxane) (PDMS) by soft lithography due to the favorable properties of PDMS: biocompatible, elastomeric, transparent, gas-permeable, inexpensive, and copyright-free. However, PDMS molding involves tedious manual labor, which makes PDMS devices prone to assembly failures and difficult to disseminate to research and clinical settings. Furthermore, the fabrication procedures limit the 3D complexity of the devices to layered designs. Stereolithography (SL), a form of 3D-printing, has recently attracted attention as a way to customize the fabrication of biomedical devices due to its automated, assembly-free 3D fabrication, rapidly decreasing costs, and fast-improving resolution and throughput. However, existing SL resins are not biocompatible and patterning transparent resins at high resolution remains difficult. Here we report procedures for the preparation and patterning of a transparent resin based on low-MW poly(ethylene glycol) diacrylate (MW 250) (PEG-DA-250). The 3D-printed devices are highly transparent and cells can be cultured on PEG-DA-250 prints for several days. This biocompatible SL resin and printing process solves some of the main drawbacks of 3D-printed microfluidic devices: biocompatibility and transparency. In addition, it should also enable the production of non-microfluidic biomedical devices.</dcterms:abstract>
<dc:date>2016</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:identifier>Urrios A, Parra-Cabrera C, Bhattacharjee N, Gonzalez-Suarez AM, Rigat-Brugarolas LG, Nallapatti U et al. 3D-printing of transparent bio-microfluidic devices in PEG-DA. Lab Chip. 2016 Jun 21;16(12):2287-94. DOI: 10.1039/c6lc00153j</dc:identifier>
<dc:identifier>1473-0197</dc:identifier>
<dc:identifier>http://hdl.handle.net/10230/35989</dc:identifier>
<dc:identifier>http://dx.doi.org/10.1039/c6lc00153j</dc:identifier>
<dc:language>eng</dc:language>
<dc:relation>Lab on a Chip. 2016 Jun 21;16(12):2287-94</dc:relation>
<dc:relation>info:eu-repo/grantAgreement/ES/1PE/BFU2015-64437-P</dc:relation>
<dc:relation>info:eu-repo/grantAgreement/EC/FP7/294294</dc:relation>
<dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
<dc:rights>© Royal Society of Chemistry</dc:rights>
<dc:publisher>Royal Society of Chemistry</dc:publisher>
</qdc:qualifieddc>
<?xml version="1.0" encoding="UTF-8" ?>
<rdf:RDF schemaLocation="http://www.openarchives.org/OAI/2.0/rdf/ http://www.openarchives.org/OAI/2.0/rdf.xsd">
<ow:Publication about="oai:repositori.upf.edu:10230/35989">
<dc:title>3D-printing of transparent bio-microfluidic devices in PEG-DA</dc:title>
<dc:creator>Urrios Garcia, Arturo, 1990-</dc:creator>
<dc:creator>Parra-Cabrera, Cesar</dc:creator>
<dc:creator>Bhattacharjee, Nirveek</dc:creator>
<dc:creator>Gonzalez-Suarez, Alan M.</dc:creator>
<dc:creator>Rigat-Brugarolas, Luis G.</dc:creator>
<dc:creator>Nallapatti, Umashree</dc:creator>
<dc:creator>Samitier, Josep</dc:creator>
<dc:creator>DeForest, Cole A.</dc:creator>
<dc:creator>Posas Garriga, Francesc</dc:creator>
<dc:creator>Garcia-Cordero, José L.</dc:creator>
<dc:creator>Folch, Albert</dc:creator>
<dc:description>The vast majority of microfluidic systems are molded in poly(dimethylsiloxane) (PDMS) by soft lithography due to the favorable properties of PDMS: biocompatible, elastomeric, transparent, gas-permeable, inexpensive, and copyright-free. However, PDMS molding involves tedious manual labor, which makes PDMS devices prone to assembly failures and difficult to disseminate to research and clinical settings. Furthermore, the fabrication procedures limit the 3D complexity of the devices to layered designs. Stereolithography (SL), a form of 3D-printing, has recently attracted attention as a way to customize the fabrication of biomedical devices due to its automated, assembly-free 3D fabrication, rapidly decreasing costs, and fast-improving resolution and throughput. However, existing SL resins are not biocompatible and patterning transparent resins at high resolution remains difficult. Here we report procedures for the preparation and patterning of a transparent resin based on low-MW poly(ethylene glycol) diacrylate (MW 250) (PEG-DA-250). The 3D-printed devices are highly transparent and cells can be cultured on PEG-DA-250 prints for several days. This biocompatible SL resin and printing process solves some of the main drawbacks of 3D-printed microfluidic devices: biocompatibility and transparency. In addition, it should also enable the production of non-microfluidic biomedical devices.</dc:description>
<dc:date>2016</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:identifier>Urrios A, Parra-Cabrera C, Bhattacharjee N, Gonzalez-Suarez AM, Rigat-Brugarolas LG, Nallapatti U et al. 3D-printing of transparent bio-microfluidic devices in PEG-DA. Lab Chip. 2016 Jun 21;16(12):2287-94. DOI: 10.1039/c6lc00153j</dc:identifier>
<dc:identifier>1473-0197</dc:identifier>
<dc:identifier>http://hdl.handle.net/10230/35989</dc:identifier>
<dc:identifier>http://dx.doi.org/10.1039/c6lc00153j</dc:identifier>
<dc:language>eng</dc:language>
<dc:relation>Lab on a Chip. 2016 Jun 21;16(12):2287-94</dc:relation>
<dc:relation>info:eu-repo/grantAgreement/ES/1PE/BFU2015-64437-P</dc:relation>
<dc:relation>info:eu-repo/grantAgreement/EC/FP7/294294</dc:relation>
<dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
<dc:rights>© Royal Society of Chemistry</dc:rights>
<dc:publisher>Royal Society of Chemistry</dc:publisher>
</ow:Publication>
</rdf:RDF>
<?xml version="1.0" encoding="UTF-8" ?>
<metadata schemaLocation="http://www.lyncode.com/xoai http://www.lyncode.com/xsd/xoai.xsd">
<element name="dc">
<element name="contributor">
<element name="author">
<element name="none">
<field name="value">Urrios Garcia, Arturo, 1990-</field>
<field name="value">Parra-Cabrera, Cesar</field>
<field name="value">Bhattacharjee, Nirveek</field>
<field name="value">Gonzalez-Suarez, Alan M.</field>
<field name="value">Rigat-Brugarolas, Luis G.</field>
<field name="value">Nallapatti, Umashree</field>
<field name="value">Samitier, Josep</field>
<field name="value">DeForest, Cole A.</field>
<field name="value">Posas Garriga, Francesc</field>
<field name="value">Garcia-Cordero, José L.</field>
<field name="value">Folch, Albert</field>
</element>
</element>
</element>
<element name="date">
<element name="accessioned">
<element name="none">
<field name="value">2018-12-05T08:33:13Z</field>
</element>
</element>
<element name="available">
<element name="none">
<field name="value">2018-12-05T08:33:13Z</field>
</element>
</element>
<element name="issued">
<element name="none">
<field name="value">2016</field>
</element>
</element>
</element>
<element name="identifier">
<element name="citation">
<element name="none">
<field name="value">Urrios A, Parra-Cabrera C, Bhattacharjee N, Gonzalez-Suarez AM, Rigat-Brugarolas LG, Nallapatti U et al. 3D-printing of transparent bio-microfluidic devices in PEG-DA. Lab Chip. 2016 Jun 21;16(12):2287-94. DOI: 10.1039/c6lc00153j</field>
</element>
</element>
<element name="issn">
<element name="none">
<field name="value">1473-0197</field>
</element>
</element>
<element name="uri">
<element name="none">
<field name="value">http://hdl.handle.net/10230/35989</field>
</element>
</element>
<element name="doi">
<element name="none">
<field name="value">http://dx.doi.org/10.1039/c6lc00153j</field>
</element>
</element>
</element>
<element name="description">
<element name="abstract">
<element name="none">
<field name="value">The vast majority of microfluidic systems are molded in poly(dimethylsiloxane) (PDMS) by soft lithography due to the favorable properties of PDMS: biocompatible, elastomeric, transparent, gas-permeable, inexpensive, and copyright-free. However, PDMS molding involves tedious manual labor, which makes PDMS devices prone to assembly failures and difficult to disseminate to research and clinical settings. Furthermore, the fabrication procedures limit the 3D complexity of the devices to layered designs. Stereolithography (SL), a form of 3D-printing, has recently attracted attention as a way to customize the fabrication of biomedical devices due to its automated, assembly-free 3D fabrication, rapidly decreasing costs, and fast-improving resolution and throughput. However, existing SL resins are not biocompatible and patterning transparent resins at high resolution remains difficult. Here we report procedures for the preparation and patterning of a transparent resin based on low-MW poly(ethylene glycol) diacrylate (MW 250) (PEG-DA-250). The 3D-printed devices are highly transparent and cells can be cultured on PEG-DA-250 prints for several days. This biocompatible SL resin and printing process solves some of the main drawbacks of 3D-printed microfluidic devices: biocompatibility and transparency. In addition, it should also enable the production of non-microfluidic biomedical devices.</field>
</element>
</element>
<element name="provenance">
<element name="en">
<field name="value">Made available in DSpace on 2018-12-05T08:33:13Z (GMT). No. of bitstreams: 1 Urr_LC_3D.pdf: 896437 bytes, checksum: 1d0051dc7909840b227c2b0b4f68f22a (MD5) Previous issue date: 2016</field>
</element>
</element>
<element name="sponsorship">
<element name="none">
<field name="value">The Ilios 3D-Printer is on loan from 3D-Skema, Inc. A. U. is a recipient of a “La Caixa” fellowship from Catalonia and an European Molecular Biology Organization (EMBO) short-term fellowship. C. P. is a recipient of a “Consejo Nacional de Ciencia y Tecnología” (CONACYT) Mexican fellowship. F. P. is supported by the Spanish Ministry of Economy and Competitiveness (BFU2015-64437-P and FEDER), the Catalan Government (2014 SGR 599) and an ERC Advanced Grant Number 294294 from the European Union seventh framework program (SYNCOM). F. P. is supported by Fundación Botín, by Banco Santander through its Santander Universities Global Division and recipient of an ICREA Acadèmia (Generalitat de Catalunya). For the cell culture data and cell microscopy, we acknowledge partial support from the National Institutes of Health, grant number 1R01NS064387-01A2</field>
</element>
</element>
</element>
<element name="format">
<element name="mimetype">
<element name="none">
<field name="value">application/pdf</field>
</element>
</element>
</element>
<element name="language">
<element name="iso">
<element name="none">
<field name="value">eng</field>
</element>
</element>
</element>
<element name="publisher">
<element name="none">
<field name="value">Royal Society of Chemistry</field>
</element>
</element>
<element name="relation">
<element name="ispartof">
<element name="none">
<field name="value">Lab on a Chip. 2016 Jun 21;16(12):2287-94</field>
</element>
</element>
<element name="projectID">
<element name="none">
<field name="value">info:eu-repo/grantAgreement/ES/1PE/BFU2015-64437-P</field>
<field name="value">info:eu-repo/grantAgreement/EC/FP7/294294</field>
</element>
</element>
</element>
<element name="rights">
<element name="none">
<field name="value">© Royal Society of Chemistry</field>
</element>
<element name="accessRights">
<element name="none">
<field name="value">info:eu-repo/semantics/openAccess</field>
</element>
</element>
</element>
<element name="subject">
<element name="other">
<element name="none">
<field name="value">Microfluídica</field>
<field name="value">Polietilenglicol</field>
<field name="value">Disseny assistit per ordinador</field>
</element>
</element>
</element>
<element name="title">
<element name="none">
<field name="value">3D-printing of transparent bio-microfluidic devices in PEG-DA</field>
</element>
</element>
<element name="type">
<element name="none">
<field name="value">info:eu-repo/semantics/article</field>
</element>
<element name="version">
<element name="none">
<field name="value">info:eu-repo/semantics/acceptedVersion</field>
</element>
</element>
</element>
</element>
<element name="bundles">
<element name="bundle">
<field name="name">THUMBNAIL</field>
<element name="bitstreams">
<element name="bitstream">
<field name="name">Urr_LC_3D.pdf.jpg</field>
<field name="originalName">Urr_LC_3D.pdf.jpg</field>
<field name="description">IM Thumbnail</field>
<field name="format">image/jpeg</field>
<field name="size">16171</field>
<field name="url">http://repositori.upf.edu/bitstream/10230/35989/3/Urr_LC_3D.pdf.jpg</field>
<field name="checksum">49423edd6cbda37804672a5c1812733a</field>
<field name="checksumAlgorithm">MD5</field>
<field name="sid">3</field>
</element>
</element>
</element>
<element name="bundle">
<field name="name">TEXT</field>
<element name="bitstreams">
<element name="bitstream">
<field name="name">Urr_LC_3D.pdf.txt</field>
<field name="originalName">Urr_LC_3D.pdf.txt</field>
<field name="description">Extracted text</field>
<field name="format">text/plain</field>
<field name="size">38283</field>
<field name="url">http://repositori.upf.edu/bitstream/10230/35989/2/Urr_LC_3D.pdf.txt</field>
<field name="checksum">339d74a69157fe630676a70f55813549</field>
<field name="checksumAlgorithm">MD5</field>
<field name="sid">2</field>
</element>
</element>
</element>
<element name="bundle">
<field name="name">ORIGINAL</field>
<element name="bitstreams">
<element name="bitstream">
<field name="name">Urr_LC_3D.pdf</field>
<field name="format">application/pdf</field>
<field name="size">896437</field>
<field name="url">http://repositori.upf.edu/bitstream/10230/35989/1/Urr_LC_3D.pdf</field>
<field name="checksum">1d0051dc7909840b227c2b0b4f68f22a</field>
<field name="checksumAlgorithm">MD5</field>
<field name="sid">1</field>
</element>
</element>
</element>
</element>
<element name="others">
<field name="handle">10230/35989</field>
<field name="identifier">oai:repositori.upf.edu:10230/35989</field>
<field name="lastModifyDate">2021-04-14 12:19:33.627</field>
</element>
<element name="repository">
<field name="name">Repositori digital de la UPF</field>
<field name="mail">repositori@upf.edu</field>
</element>
</metadata>