<?xml version="1.0" encoding="UTF-8" ?>
<oai_dc:dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:creator>Nicolas, M.</dc:creator>
<dc:creator>Lucea, B.</dc:creator>
<dc:creator>Laborda García, Alicia</dc:creator>
<dc:creator>Peña, E.</dc:creator>
<dc:creator>Gregorio, M.A. de</dc:creator>
<dc:creator>Martinez, M.A.</dc:creator>
<dc:creator>Malve, M.</dc:creator>
<dc:title>Influence of a commercial antithrombotic filter on the caval blood flow during neutra and valsalva maneuver</dc:title>
<dc:identifier>http://zaguan.unizar.es/record/78213</dc:identifier>
<dc:description>Anticoagulants are the treatment of choice for pulmonary embolism. When these fail or are contraindicated, vena cava filters are effective devices for preventing clots from the legs from migrating to the lung. Many uncertainties exist when a filter is inserted, especially during physiological activity such as normal breathing and the Valsalva maneuver. These activities are often connected with filter migration and vena cava damage due to the various related vein geometrical configurations. In this work, we analyzed the response of the vena cava during normal breathing and Valsalva maneuver, for a healthy vena cava and after insertion of a commercial Günther-Tulip® filter. Validated computational fluid dynamics (CFD) and patient specific data are used for analyzing blood flow inside the vena cava during these maneuvers. While during normal breathing, the vena cava flow can be considered almost stationary with a very low pressure gradient, during Valsalva the extravascular pressure compresses the vena cava resulting in a drastic reduction of the vein section, a global flow decrease through the cava but increasing the velocity magnitude. This change in the section is altered by the presence of the filter which forces the section of the vena cava before the renal veins to keep open. The effect of the presence of the filter is investigated during these maneuvers showing changes in wall shear stress and velocity patterns.</dc:description>
<dc:format>application/pdf</dc:format>
<dc:language>eng</dc:language>
<dc:date>2017</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/submittedVersion</dc:type>
<dc:rights>by-nc</dc:rights>
<dc:rights>http://creativecommons.org/licenses/by-nc/3.0/es/</dc:rights>
<dc:relation>info:eu-repo/grantAgreement/ES/DGA/B21-GITMI</dc:relation>
<dc:relation>info:eu-repo/grantAgreement/ES/ISCIII/PI08-1424</dc:relation>
<dc:relation>info:eu-repo/grantAgreement/ES/MINECO/DPI2010-20746-C03-01</dc:relation>
<dc:relation>info:eu-repo/grantAgreement/ES/MINECO/DPI2013-44391-P</dc:relation>
<dc:relation>info:eu-repo/grantAgreement/ES/MINECO/DPI2016-76630-C2-1-R</dc:relation>
<dc:identifier>10.1115/1.4035983</dc:identifier>
</oai_dc:dc>
<?xml version="1.0" encoding="UTF-8" ?>
<marc:record type="Bibliographic" schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<marc:leader>00000coc 2200000uu 4500</marc:leader>
<marc:controlfield tag="001">78213</marc:controlfield>
<marc:controlfield tag="005">20190709135636.0</marc:controlfield>
<marc:datafield ind1="7" ind2=" " tag="024">
<marc:subfield code="2">doi</marc:subfield>
<marc:subfield code="a">10.1115/1.4035983</marc:subfield>
</marc:datafield>
<marc:datafield ind1="8" ind2=" " tag="024">
<marc:subfield code="2">sideral</marc:subfield>
<marc:subfield code="a">99556</marc:subfield>
</marc:datafield>
<marc:datafield ind1=" " ind2=" " tag="037">
<marc:subfield code="a">ART-2017-99556</marc:subfield>
</marc:datafield>
<marc:datafield ind1=" " ind2=" " tag="041">
<marc:subfield code="a">eng</marc:subfield>
</marc:datafield>
<marc:datafield ind1=" " ind2=" " tag="100">
<marc:subfield code="0">(orcid)0000-0001-7514-3717</marc:subfield>
<marc:subfield code="a">Nicolas, M.</marc:subfield>
</marc:datafield>
<marc:datafield ind1=" " ind2=" " tag="245">
<marc:subfield code="a">Influence of a commercial antithrombotic filter on the caval blood flow during neutra and valsalva maneuver</marc:subfield>
</marc:datafield>
<marc:datafield ind1=" " ind2=" " tag="260">
<marc:subfield code="c">2017</marc:subfield>
</marc:datafield>
<marc:datafield ind1="0" ind2=" " tag="506">
<marc:subfield code="a">Access copy available to the general public</marc:subfield>
<marc:subfield code="f">Unrestricted</marc:subfield>
</marc:datafield>
<marc:datafield ind1="3" ind2=" " tag="520">
<marc:subfield code="a">Anticoagulants are the treatment of choice for pulmonary embolism. When these fail or are contraindicated, vena cava filters are effective devices for preventing clots from the legs from migrating to the lung. Many uncertainties exist when a filter is inserted, especially during physiological activity such as normal breathing and the Valsalva maneuver. These activities are often connected with filter migration and vena cava damage due to the various related vein geometrical configurations. In this work, we analyzed the response of the vena cava during normal breathing and Valsalva maneuver, for a healthy vena cava and after insertion of a commercial Günther-Tulip® filter. Validated computational fluid dynamics (CFD) and patient specific data are used for analyzing blood flow inside the vena cava during these maneuvers. While during normal breathing, the vena cava flow can be considered almost stationary with a very low pressure gradient, during Valsalva the extravascular pressure compresses the vena cava resulting in a drastic reduction of the vein section, a global flow decrease through the cava but increasing the velocity magnitude. This change in the section is altered by the presence of the filter which forces the section of the vena cava before the renal veins to keep open. The effect of the presence of the filter is investigated during these maneuvers showing changes in wall shear stress and velocity patterns.</marc:subfield>
</marc:datafield>
<marc:datafield ind1=" " ind2=" " tag="536">
<marc:subfield code="9">info:eu-repo/grantAgreement/ES/DGA/B21-GITMI</marc:subfield>
<marc:subfield code="9">info:eu-repo/grantAgreement/ES/ISCIII/PI08-1424</marc:subfield>
<marc:subfield code="9">info:eu-repo/grantAgreement/ES/MINECO/DPI2010-20746-C03-01</marc:subfield>
<marc:subfield code="9">info:eu-repo/grantAgreement/ES/MINECO/DPI2013-44391-P</marc:subfield>
<marc:subfield code="9">info:eu-repo/grantAgreement/ES/MINECO/DPI2016-76630-C2-1-R</marc:subfield>
</marc:datafield>
<marc:datafield ind1=" " ind2=" " tag="540">
<marc:subfield code="9">info:eu-repo/semantics/openAccess</marc:subfield>
<marc:subfield code="a">by-nc</marc:subfield>
<marc:subfield code="u">http://creativecommons.org/licenses/by-nc/3.0/es/</marc:subfield>
</marc:datafield>
<marc:datafield ind1=" " ind2=" " tag="590">
<marc:subfield code="a">0.412</marc:subfield>
<marc:subfield code="b">2017</marc:subfield>
</marc:datafield>
<marc:datafield ind1=" " ind2=" " tag="591">
<marc:subfield code="a">ENGINEERING, BIOMEDICAL</marc:subfield>
<marc:subfield code="b">77 / 78 = 0.987</marc:subfield>
<marc:subfield code="c">2017</marc:subfield>
<marc:subfield code="d">Q4</marc:subfield>
<marc:subfield code="e">T3</marc:subfield>
</marc:datafield>
<marc:datafield ind1=" " ind2=" " tag="592">
<marc:subfield code="a">0.223</marc:subfield>
<marc:subfield code="b">2017</marc:subfield>
</marc:datafield>
<marc:datafield ind1=" " ind2=" " tag="593">
<marc:subfield code="a">Medicine (miscellaneous)</marc:subfield>
<marc:subfield code="c">2017</marc:subfield>
<marc:subfield code="d">Q3</marc:subfield>
</marc:datafield>
<marc:datafield ind1=" " ind2=" " tag="593">
<marc:subfield code="a">Biomedical Engineering</marc:subfield>
<marc:subfield code="c">2017</marc:subfield>
<marc:subfield code="d">Q3</marc:subfield>
</marc:datafield>
<marc:datafield ind1=" " ind2="4" tag="655">
<marc:subfield code="a">info:eu-repo/semantics/article</marc:subfield>
<marc:subfield code="v">info:eu-repo/semantics/submittedVersion</marc:subfield>
</marc:datafield>
<marc:datafield ind1=" " ind2=" " tag="700">
<marc:subfield code="a">Lucea, B.</marc:subfield>
</marc:datafield>
<marc:datafield ind1=" " ind2=" " tag="700">
<marc:subfield code="0">(orcid)0000-0003-0296-1617</marc:subfield>
<marc:subfield code="a">Laborda García, Alicia</marc:subfield>
<marc:subfield code="u">Universidad de Zaragoza</marc:subfield>
</marc:datafield>
<marc:datafield ind1=" " ind2=" " tag="700">
<marc:subfield code="0">(orcid)0000-0002-0664-5024</marc:subfield>
<marc:subfield code="a">Peña, E.</marc:subfield>
<marc:subfield code="u">Universidad de Zaragoza</marc:subfield>
</marc:datafield>
<marc:datafield ind1=" " ind2=" " tag="700">
<marc:subfield code="0">(orcid)0000-0002-5618-7519</marc:subfield>
<marc:subfield code="a">Gregorio, M.A. de</marc:subfield>
<marc:subfield code="u">Universidad de Zaragoza</marc:subfield>
</marc:datafield>
<marc:datafield ind1=" " ind2=" " tag="700">
<marc:subfield code="0">(orcid)0000-0002-8375-0354</marc:subfield>
<marc:subfield code="a">Martinez, M.A.</marc:subfield>
<marc:subfield code="u">Universidad de Zaragoza</marc:subfield>
</marc:datafield>
<marc:datafield ind1=" " ind2=" " tag="700">
<marc:subfield code="0">(orcid)0000-0002-0116-2736</marc:subfield>
<marc:subfield code="a">Malve, M.</marc:subfield>
</marc:datafield>
<marc:datafield ind1="2" ind2=" " tag="710">
<marc:subfield code="1">1010</marc:subfield>
<marc:subfield code="2">770</marc:subfield>
<marc:subfield code="a">Universidad de Zaragoza</marc:subfield>
<marc:subfield code="b">Dpto. Pediatría Radiol.Med.Fís</marc:subfield>
<marc:subfield code="c">Área Radiol. y Medicina Física</marc:subfield>
</marc:datafield>
<marc:datafield ind1="2" ind2=" " tag="710">
<marc:subfield code="1">5004</marc:subfield>
<marc:subfield code="2">605</marc:subfield>
<marc:subfield code="a">Universidad de Zaragoza</marc:subfield>
<marc:subfield code="b">Dpto. Ingeniería Mecánica</marc:subfield>
<marc:subfield code="c">Área Mec.Med.Cont. y Teor.Est.</marc:subfield>
</marc:datafield>
<marc:datafield ind1="2" ind2=" " tag="710">
<marc:subfield code="1">1009</marc:subfield>
<marc:subfield code="2">617</marc:subfield>
<marc:subfield code="a">Universidad de Zaragoza</marc:subfield>
<marc:subfield code="b">Dpto. Patología Animal</marc:subfield>
<marc:subfield code="c">Área Medicina y Cirugía Animal</marc:subfield>
</marc:datafield>
<marc:datafield ind1=" " ind2=" " tag="773">
<marc:subfield code="g">11, 3 (2017), 031002 [11 pp.]</marc:subfield>
<marc:subfield code="p">JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME</marc:subfield>
<marc:subfield code="t">JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME</marc:subfield>
<marc:subfield code="x">1932-6181</marc:subfield>
</marc:datafield>
<marc:datafield ind1="4" ind2=" " tag="856">
<marc:subfield code="s">443962</marc:subfield>
<marc:subfield code="u">http://zaguan.unizar.es/record/78213/files/texto_completo.pdf</marc:subfield>
<marc:subfield code="y">Preprint</marc:subfield>
</marc:datafield>
<marc:datafield ind1="4" ind2=" " tag="856">
<marc:subfield code="s">53407</marc:subfield>
<marc:subfield code="u">http://zaguan.unizar.es/record/78213/files/texto_completo.jpg?subformat=icon</marc:subfield>
<marc:subfield code="x">icon</marc:subfield>
<marc:subfield code="y">Preprint</marc:subfield>
</marc:datafield>
<marc:datafield ind1="C" ind2="O" tag="909">
<marc:subfield code="o">oai:zaguan.unizar.es:78213</marc:subfield>
<marc:subfield code="p">articulos</marc:subfield>
<marc:subfield code="p">driver</marc:subfield>
</marc:datafield>
<marc:datafield ind1=" " ind2=" " tag="951">
<marc:subfield code="a">2019-07-09-12:36:04</marc:subfield>
</marc:datafield>
<marc:datafield ind1=" " ind2=" " tag="980">
<marc:subfield code="a">ARTICLE</marc:subfield>
</marc:datafield>
</marc:record>