<?xml version="1.0" encoding="UTF-8" ?>
<oai_dc:dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title>3D reconstruction of the proximal femur and lumbar vertebrae from dual-energy x-ray absorptiometry for osteoporotic risk assessment</dc:title>
<dc:creator>Whitmarsh, Tristan</dc:creator>
<dc:contributor>Frangi Caregnato, Alejandro</dc:contributor>
<dc:contributor>Humbert, Ludovic</dc:contributor>
<dc:contributor>Universitat Pompeu Fabra. Departament de Tecnologies de la Informació i les Comunicacions</dc:contributor>
<dc:subject>Osteoporosis</dc:subject>
<dc:subject>Fracture</dc:subject>
<dc:subject>Fracture risk assessment</dc:subject>
<dc:subject>Statistical model</dc:subject>
<dc:subject>Registration</dc:subject>
<dc:subject>Reconstruction</dc:subject>
<dc:subject>Femur</dc:subject>
<dc:subject>Vertebrae</dc:subject>
<dc:subject>Computed Tomography</dc:subject>
<dc:subject>Dual-energy</dc:subject>
<dc:subject>X-ray</dc:subject>
<dc:subject>Absorptiometry</dc:subject>
<dc:subject>Bone Mineral Density</dc:subject>
<dc:subject>62</dc:subject>
<dc:description>In this thesis a method was developed to reconstruct both the 3D shape and the BMD distribution of bone structures from Dual-energy X-ray Absorptiometry (DXA) images. The method incorporates a statistical model built from a large dataset of Quantitative Computed Tomography (QCT) scans together with a 3D-2D intensity based registration process. The method was evaluated for its ability to reconstruct the proximal femur from a single DXA image. The resulting parameters of the reconstructions were subsequently evaluated for their hip fracture discrimination ability. The reconstruction method was finally extended to the reconstruction of the lumbar vertebrae from anteroposterior and lateral DXA, thereby incorporating a multi-object and multi-view approach. These techniques can potentially improve the fracture risk estimation accuracy over current clinical practice.</dc:description>
<dc:description>En esta tesis se desarrolló un método para reconstruir tanto la forma 3D de estructuras óseas como la distribución de la DMO a partir de una sola imagen de DXA. El método incorpora un modelo estadístico construido a partir de una gran base de datos de QCT junto con una técnica de registro 3D-2D basada en intensidades. Se ha evaluado la capacidad del método para reconstruir la parte proximal del fémur a partir de una imagen DXA. Los parámetros resultantes de las reconstrucciones fueron evaluados posteriormente por su capacidad en discriminar una fractura de cadera. Por fin, se extendió el método a la reconstrucción de las vértebras lumbares a partir de DXA anteroposterior y lateral incorporando así un enfoque multi-objeto y multi-vista. Estos técnicas pueden potencialmente mejorar la precisión en la estimación del riesgo de fractura respecto a la estimación que ofrece la práctica clínica actual.</dc:description>
<dc:description>Programa de doctorat en Tecnologies de la Informació i les Comunicacions</dc:description>
<dc:date>2012-11-14T09:43:13Z</dc:date>
<dc:date>2012-11-14T09:43:13Z</dc:date>
<dc:date>2012-09-25</dc:date>
<dc:type>info:eu-repo/semantics/doctoralThesis</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:identifier>http://hdl.handle.net/10803/94492</dc:identifier>
<dc:identifier>B. 32040-2012</dc:identifier>
<dc:language>eng</dc:language>
<dc:rights>ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.</dc:rights>
<dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
<dc:format>96 p.</dc:format>
<dc:format>application/pdf</dc:format>
<dc:format>application/pdf</dc:format>
<dc:publisher>Universitat Pompeu Fabra</dc:publisher>
<dc:source>TDX (Tesis Doctorals en Xarxa)</dc:source>
</oai_dc:dc>
<?xml version="1.0" encoding="UTF-8" ?>
<dim:dim schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
<dim:field element="contributor" mdschema="dc">Universitat Pompeu Fabra. Departament de Tecnologies de la Informació i les Comunicacions</dim:field>
<dim:field authority="d0e6c0c8-bd39-4ee8-b532-ecbf32ed20c2" confidence="-1" element="contributor" mdschema="dc" qualifier="author">Whitmarsh, Tristan</dim:field>
<dim:field element="contributor" lang="cat" mdschema="dc" qualifier="authoremail">twhitmarsh@cistib.upf.edu</dim:field>
<dim:field element="contributor" lang="cat" mdschema="dc" qualifier="authoremailshow">true</dim:field>
<dim:field authority="c0a5d95e-a11f-4c95-b030-c6cd5ff231c2" confidence="-1" element="contributor" mdschema="dc" qualifier="director">Frangi Caregnato, Alejandro</dim:field>
<dim:field authority="0f121804-7de0-40f0-b1d8-a3d2926b5978" confidence="-1" element="contributor" mdschema="dc" qualifier="director">Humbert, Ludovic</dim:field>
<dim:field element="contributor" lang="cat" mdschema="dc" qualifier="authorsendemail">true</dim:field>
<dim:field element="date" mdschema="dc" qualifier="accessioned">2012-11-14T09:43:13Z</dim:field>
<dim:field element="date" mdschema="dc" qualifier="available">2012-11-14T09:43:13Z</dim:field>
<dim:field element="date" mdschema="dc" qualifier="issued">2012-09-25</dim:field>
<dim:field element="identifier" mdschema="dc" qualifier="uri">http://hdl.handle.net/10803/94492</dim:field>
<dim:field element="identifier" lang="cat" mdschema="dc" qualifier="dl">B. 32040-2012</dim:field>
<dim:field element="description" lang="eng" mdschema="dc" qualifier="abstract">In this thesis a method was developed to reconstruct both the 3D shape and the BMD distribution of bone structures from Dual-energy X-ray Absorptiometry (DXA) images. The method incorporates a statistical model built from a large dataset of Quantitative Computed Tomography (QCT) scans together with a 3D-2D intensity based registration process. The method was evaluated for its ability to reconstruct the proximal femur from a single DXA image. The resulting parameters of the reconstructions were subsequently evaluated for their hip fracture discrimination ability. The reconstruction method was finally extended to the reconstruction of the lumbar vertebrae from anteroposterior and lateral DXA, thereby incorporating a multi-object and multi-view approach. These techniques can potentially improve the fracture risk estimation accuracy over current clinical practice.</dim:field>
<dim:field element="description" lang="spa" mdschema="dc" qualifier="abstract">En esta tesis se desarrolló un método para reconstruir tanto la forma 3D de estructuras óseas como la distribución de la DMO a partir de una sola imagen de DXA. El método incorpora un modelo estadístico construido a partir de una gran base de datos de QCT junto con una técnica de registro 3D-2D basada en intensidades. Se ha evaluado la capacidad del método para reconstruir la parte proximal del fémur a partir de una imagen DXA. Los parámetros resultantes de las reconstrucciones fueron evaluados posteriormente por su capacidad en discriminar una fractura de cadera. Por fin, se extendió el método a la reconstrucción de las vértebras lumbares a partir de DXA anteroposterior y lateral incorporando así un enfoque multi-objeto y multi-vista. Estos técnicas pueden potencialmente mejorar la precisión en la estimación del riesgo de fractura respecto a la estimación que ofrece la práctica clínica actual.</dim:field>
<dim:field element="description" mdschema="dc" qualifier="degree">Programa de doctorat en Tecnologies de la Informació i les Comunicacions</dim:field>
<dim:field element="format" lang="cat" mdschema="dc" qualifier="extent">96 p.</dim:field>
<dim:field element="format" mdschema="dc" qualifier="mimetype">application/pdf</dim:field>
<dim:field element="language" lang="cat" mdschema="dc" qualifier="iso">eng</dim:field>
<dim:field element="publisher" mdschema="dc">Universitat Pompeu Fabra</dim:field>
<dim:field element="rights" mdschema="dc" qualifier="license">ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.</dim:field>
<dim:field element="rights" mdschema="dc" qualifier="accessLevel">info:eu-repo/semantics/openAccess</dim:field>
<dim:field element="source" mdschema="dc">TDX (Tesis Doctorals en Xarxa)</dim:field>
<dim:field element="subject" lang="cat" mdschema="dc">Osteoporosis</dim:field>
<dim:field element="subject" lang="cat" mdschema="dc">Fracture</dim:field>
<dim:field element="subject" lang="cat" mdschema="dc">Fracture risk assessment</dim:field>
<dim:field element="subject" lang="cat" mdschema="dc">Statistical model</dim:field>
<dim:field element="subject" lang="cat" mdschema="dc">Registration</dim:field>
<dim:field element="subject" lang="cat" mdschema="dc">Reconstruction</dim:field>
<dim:field element="subject" lang="cat" mdschema="dc">Femur</dim:field>
<dim:field element="subject" lang="cat" mdschema="dc">Vertebrae</dim:field>
<dim:field element="subject" lang="cat" mdschema="dc">Computed Tomography</dim:field>
<dim:field element="subject" lang="cat" mdschema="dc">Dual-energy</dim:field>
<dim:field element="subject" lang="cat" mdschema="dc">X-ray</dim:field>
<dim:field element="subject" lang="cat" mdschema="dc">Absorptiometry</dim:field>
<dim:field element="subject" lang="cat" mdschema="dc">Bone Mineral Density</dim:field>
<dim:field element="subject" lang="cat" mdschema="dc" qualifier="udc">62</dim:field>
<dim:field element="title" lang="cat" mdschema="dc">3D reconstruction of the proximal femur and lumbar vertebrae from dual-energy x-ray absorptiometry for osteoporotic risk assessment</dim:field>
<dim:field element="type" mdschema="dc">info:eu-repo/semantics/doctoralThesis</dim:field>
<dim:field element="type" mdschema="dc">info:eu-repo/semantics/publishedVersion</dim:field>
<dim:field element="embargo" lang="cat" mdschema="dc" qualifier="terms">cap</dim:field>
</dim:dim>
<?xml version="1.0" encoding="UTF-8" ?>
<thesis schemaLocation="http://www.ndltd.org/standards/metadata/etdms/1.0/ http://www.ndltd.org/standards/metadata/etdms/1.0/etdms.xsd">
<title>3D reconstruction of the proximal femur and lumbar vertebrae from dual-energy x-ray absorptiometry for osteoporotic risk assessment</title>
<creator>Whitmarsh, Tristan</creator>
<contributor>twhitmarsh@cistib.upf.edu</contributor>
<contributor>true</contributor>
<contributor>Frangi Caregnato, Alejandro</contributor>
<contributor>Humbert, Ludovic</contributor>
<contributor>true</contributor>
<subject>Osteoporosis</subject>
<subject>Fracture</subject>
<subject>Fracture risk assessment</subject>
<subject>Statistical model</subject>
<subject>Registration</subject>
<subject>Reconstruction</subject>
<subject>Femur</subject>
<subject>Vertebrae</subject>
<subject>Computed Tomography</subject>
<subject>Dual-energy</subject>
<subject>X-ray</subject>
<subject>Absorptiometry</subject>
<subject>Bone Mineral Density</subject>
<description>In this thesis a method was developed to reconstruct both the 3D shape and the BMD distribution of bone structures from Dual-energy X-ray Absorptiometry (DXA) images. The method incorporates a statistical model built from a large dataset of Quantitative Computed Tomography (QCT) scans together with a 3D-2D intensity based registration process. The method was evaluated for its ability to reconstruct the proximal femur from a single DXA image. The resulting parameters of the reconstructions were subsequently evaluated for their hip fracture discrimination ability. The reconstruction method was finally extended to the reconstruction of the lumbar vertebrae from anteroposterior and lateral DXA, thereby incorporating a multi-object and multi-view approach. These techniques can potentially improve the fracture risk estimation accuracy over current clinical practice.</description>
<description>En esta tesis se desarrolló un método para reconstruir tanto la forma 3D de estructuras óseas como la distribución de la DMO a partir de una sola imagen de DXA. El método incorpora un modelo estadístico construido a partir de una gran base de datos de QCT junto con una técnica de registro 3D-2D basada en intensidades. Se ha evaluado la capacidad del método para reconstruir la parte proximal del fémur a partir de una imagen DXA. Los parámetros resultantes de las reconstrucciones fueron evaluados posteriormente por su capacidad en discriminar una fractura de cadera. Por fin, se extendió el método a la reconstrucción de las vértebras lumbares a partir de DXA anteroposterior y lateral incorporando así un enfoque multi-objeto y multi-vista. Estos técnicas pueden potencialmente mejorar la precisión en la estimación del riesgo de fractura respecto a la estimación que ofrece la práctica clínica actual.</description>
<date>2012-11-14</date>
<date>2012-11-14</date>
<date>2012-09-25</date>
<type>info:eu-repo/semantics/doctoralThesis</type>
<type>info:eu-repo/semantics/publishedVersion</type>
<identifier>http://hdl.handle.net/10803/94492</identifier>
<identifier>B. 32040-2012</identifier>
<language>eng</language>
<rights>ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.</rights>
<rights>info:eu-repo/semantics/openAccess</rights>
<publisher>Universitat Pompeu Fabra</publisher>
<source>TDX (Tesis Doctorals en Xarxa)</source>
</thesis>
<?xml version="1.0" encoding="UTF-8" ?>
<record schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<leader>00925njm 22002777a 4500</leader>
<datafield ind1=" " ind2=" " tag="042">
<subfield code="a">dc</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="720">
<subfield code="a">Whitmarsh, Tristan</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="260">
<subfield code="c">2012-09-25</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="520">
<subfield code="a">In this thesis a method was developed to reconstruct both the 3D shape and the BMD distribution of bone structures from Dual-energy X-ray Absorptiometry (DXA) images. The method incorporates a statistical model built from a large dataset of Quantitative Computed Tomography (QCT) scans together with a 3D-2D intensity based registration process. The method was evaluated for its ability to reconstruct the proximal femur from a single DXA image. The resulting parameters of the reconstructions were subsequently evaluated for their hip fracture discrimination ability. The reconstruction method was finally extended to the reconstruction of the lumbar vertebrae from anteroposterior and lateral DXA, thereby incorporating a multi-object and multi-view approach. These techniques can potentially improve the fracture risk estimation accuracy over current clinical practice.</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="520">
<subfield code="a">En esta tesis se desarrolló un método para reconstruir tanto la forma 3D de estructuras óseas como la distribución de la DMO a partir de una sola imagen de DXA. El método incorpora un modelo estadístico construido a partir de una gran base de datos de QCT junto con una técnica de registro 3D-2D basada en intensidades. Se ha evaluado la capacidad del método para reconstruir la parte proximal del fémur a partir de una imagen DXA. Los parámetros resultantes de las reconstrucciones fueron evaluados posteriormente por su capacidad en discriminar una fractura de cadera. Por fin, se extendió el método a la reconstrucción de las vértebras lumbares a partir de DXA anteroposterior y lateral incorporando así un enfoque multi-objeto y multi-vista. Estos técnicas pueden potencialmente mejorar la precisión en la estimación del riesgo de fractura respecto a la estimación que ofrece la práctica clínica actual.</subfield>
</datafield>
<datafield ind1="8" ind2=" " tag="024">
<subfield code="a">http://hdl.handle.net/10803/94492</subfield>
</datafield>
<datafield ind1="8" ind2=" " tag="024">
<subfield code="a">B. 32040-2012</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Osteoporosis</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Fracture</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Fracture risk assessment</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Statistical model</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Registration</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Reconstruction</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Femur</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Vertebrae</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Computed Tomography</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Dual-energy</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">X-ray</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Absorptiometry</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Bone Mineral Density</subfield>
</datafield>
<datafield ind1="0" ind2="0" tag="245">
<subfield code="a">3D reconstruction of the proximal femur and lumbar vertebrae from dual-energy x-ray absorptiometry for osteoporotic risk assessment</subfield>
</datafield>
</record>
<?xml version="1.0" encoding="UTF-8" ?>
<record schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<leader>nam a 5i 4500</leader>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Osteoporosis</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Fracture</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Fracture risk assessment</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Statistical model</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Registration</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Reconstruction</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Femur</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Vertebrae</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Computed Tomography</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Dual-energy</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">X-ray</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Absorptiometry</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Bone Mineral Density</subfield>
</datafield>
<datafield ind1="1" ind2="0" tag="245">
<subfield code="a">3D reconstruction of the proximal femur and lumbar vertebrae from dual-energy x-ray absorptiometry for osteoporotic risk assessment</subfield>
</datafield>
<datafield ind1=" " ind2="1" tag="264">
<subfield code="a">[Barcelona] :</subfield>
<subfield code="b">Universitat Pompeu Fabra,</subfield>
<subfield code="c">2012</subfield>
</datafield>
<datafield ind1="4" ind2="0" tag="856">
<subfield code="z">Accés lliure</subfield>
<subfield code="u">http://hdl.handle.net/10803/94492</subfield>
</datafield>
<controlfield tag="007">cr |||||||||||</controlfield>
<controlfield tag="008">AAMMDDs2012 sp ||||fsm||||0|| 0 eng|c</controlfield>
<datafield ind1="1" ind2=" " tag="100">
<subfield code="a">Whitmarsh, Tristan,</subfield>
<subfield code="e">autor</subfield>
</datafield>
<datafield ind1="1" ind2=" " tag="100">
<subfield code="a">Programa de doctorat en Tecnologies de la Informació i les Comunicacions,</subfield>
<subfield code="e">degree</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="300">
<subfield code="a">1 recurs en línia (96 pàgines)</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="502">
<subfield code="g">Tesi</subfield>
<subfield code="b">Doctorat</subfield>
<subfield code="c">Universitat Pompeu Fabra. Departament de Tecnologies de la Informació i les Comunicacions</subfield>
<subfield code="d">2012</subfield>
</datafield>
<datafield ind1="2" ind2=" " tag="710">
<subfield code="a">Universitat Pompeu Fabra. Departament de Tecnologies de la Informació i les Comunicacions</subfield>
</datafield>
<datafield ind1=" " ind2="4" tag="655">
<subfield code="a">Tesis i dissertacions electròniques</subfield>
</datafield>
<datafield ind1="1" ind2=" " tag="700">
<subfield code="a">Frangi Caregnato, Alejandro,</subfield>
<subfield code="e">supervisor acadèmic</subfield>
</datafield>
<datafield ind1="1" ind2=" " tag="700">
<subfield code="a">Humbert, Ludovic,</subfield>
<subfield code="e">supervisor acadèmic</subfield>
</datafield>
<datafield ind1="0" ind2=" " tag="730">
<subfield code="a">TDX</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="520">
<subfield code="a">In this thesis a method was developed to reconstruct both the 3D shape and the BMD distribution of bone structures from Dual-energy X-ray Absorptiometry (DXA) images. The method incorporates a statistical model built from a large dataset of Quantitative Computed Tomography (QCT) scans together with a 3D-2D intensity based registration process. The method was evaluated for its ability to reconstruct the proximal femur from a single DXA image. The resulting parameters of the reconstructions were subsequently evaluated for their hip fracture discrimination ability. The reconstruction method was finally extended to the reconstruction of the lumbar vertebrae from anteroposterior and lateral DXA, thereby incorporating a multi-object and multi-view approach. These techniques can potentially improve the fracture risk estimation accuracy over current clinical practice.</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="998">
<subfield code="a">f</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="040">
<subfield code="a">ES-BaCBU</subfield>
<subfield code="b">cat</subfield>
<subfield code="e">rda</subfield>
<subfield code="c">ES-BaCBU</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="336">
<subfield code="a">text</subfield>
<subfield code="b">txt</subfield>
<subfield code="2">rdacontent</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="337">
<subfield code="a">informàtic</subfield>
<subfield code="b">c</subfield>
<subfield code="2">rdamedia</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="338">
<subfield code="a">recurs en línia</subfield>
<subfield code="b">cr</subfield>
<subfield code="2">rdacarrier</subfield>
</datafield>
</record>
<?xml version="1.0" encoding="UTF-8" ?>
<mets ID=" DSpace_ITEM_10803-94492" OBJID=" hdl:10803/94492" PROFILE="DSpace METS SIP Profile 1.0" TYPE="DSpace ITEM" schemaLocation="http://www.loc.gov/METS/ http://www.loc.gov/standards/mets/mets.xsd">
<metsHdr CREATEDATE="2024-09-07T06:25:19Z">
<agent ROLE="CUSTODIAN" TYPE="ORGANIZATION">
<name>TDX (Tesis Doctorals en Xarxa)</name>
</agent>
</metsHdr>
<dmdSec ID="DMD_10803_94492">
<mdWrap MDTYPE="MODS">
<xmlData schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
<mods:mods schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
<mods:name>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
<mods:namePart>Whitmarsh, Tristan</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">authoremail</mods:roleTerm>
</mods:role>
<mods:namePart>twhitmarsh@cistib.upf.edu</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">authoremailshow</mods:roleTerm>
</mods:role>
<mods:namePart>true</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">director</mods:roleTerm>
</mods:role>
<mods:namePart>Frangi Caregnato, Alejandro</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">director</mods:roleTerm>
</mods:role>
<mods:namePart>Humbert, Ludovic</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">authorsendemail</mods:roleTerm>
</mods:role>
<mods:namePart>true</mods:namePart>
</mods:name>
<mods:extension>
<mods:dateAccessioned encoding="iso8601">2012-11-14T09:43:13Z</mods:dateAccessioned>
</mods:extension>
<mods:extension>
<mods:dateAvailable encoding="iso8601">2012-11-14T09:43:13Z</mods:dateAvailable>
</mods:extension>
<mods:originInfo>
<mods:dateIssued encoding="iso8601">2012-09-25</mods:dateIssued>
</mods:originInfo>
<mods:identifier type="uri">http://hdl.handle.net/10803/94492</mods:identifier>
<mods:identifier type="dl">B. 32040-2012</mods:identifier>
<mods:abstract>In this thesis a method was developed to reconstruct both the 3D shape and the BMD distribution of bone structures from Dual-energy X-ray Absorptiometry (DXA) images. The method incorporates a statistical model built from a large dataset of Quantitative Computed Tomography (QCT) scans together with a 3D-2D intensity based registration process. The method was evaluated for its ability to reconstruct the proximal femur from a single DXA image. The resulting parameters of the reconstructions were subsequently evaluated for their hip fracture discrimination ability. The reconstruction method was finally extended to the reconstruction of the lumbar vertebrae from anteroposterior and lateral DXA, thereby incorporating a multi-object and multi-view approach. These techniques can potentially improve the fracture risk estimation accuracy over current clinical practice.</mods:abstract>
<mods:abstract>En esta tesis se desarrolló un método para reconstruir tanto la forma 3D de estructuras óseas como la distribución de la DMO a partir de una sola imagen de DXA. El método incorpora un modelo estadístico construido a partir de una gran base de datos de QCT junto con una técnica de registro 3D-2D basada en intensidades. Se ha evaluado la capacidad del método para reconstruir la parte proximal del fémur a partir de una imagen DXA. Los parámetros resultantes de las reconstrucciones fueron evaluados posteriormente por su capacidad en discriminar una fractura de cadera. Por fin, se extendió el método a la reconstrucción de las vértebras lumbares a partir de DXA anteroposterior y lateral incorporando así un enfoque multi-objeto y multi-vista. Estos técnicas pueden potencialmente mejorar la precisión en la estimación del riesgo de fractura respecto a la estimación que ofrece la práctica clínica actual.</mods:abstract>
<mods:language>
<mods:languageTerm authority="rfc3066">eng</mods:languageTerm>
</mods:language>
<mods:subject>
<mods:topic>Osteoporosis</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Fracture</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Fracture risk assessment</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Statistical model</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Registration</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Reconstruction</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Femur</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Vertebrae</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Computed Tomography</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Dual-energy</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>X-ray</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Absorptiometry</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Bone Mineral Density</mods:topic>
</mods:subject>
<mods:titleInfo>
<mods:title>3D reconstruction of the proximal femur and lumbar vertebrae from dual-energy x-ray absorptiometry for osteoporotic risk assessment</mods:title>
</mods:titleInfo>
<mods:genre>info:eu-repo/semantics/doctoralThesis info:eu-repo/semantics/publishedVersion</mods:genre>
</mods:mods>
</xmlData>
</mdWrap>
</dmdSec>
<amdSec ID="FO_10803_94492_1">
<techMD ID="TECH_O_10803_94492_1">
<mdWrap MDTYPE="PREMIS">
<xmlData schemaLocation="http://www.loc.gov/standards/premis http://www.loc.gov/standards/premis/PREMIS-v1-0.xsd">
<premis:premis>
<premis:object>
<premis:objectIdentifier>
<premis:objectIdentifierType>URL</premis:objectIdentifierType>
<premis:objectIdentifierValue>https://www.tdx.cat/bitstream/10803/94492/1/ttw.pdf</premis:objectIdentifierValue>
</premis:objectIdentifier>
<premis:objectCategory>File</premis:objectCategory>
<premis:objectCharacteristics>
<premis:fixity>
<premis:messageDigestAlgorithm>MD5</premis:messageDigestAlgorithm>
<premis:messageDigest>8e3b3f25dad03e902151005ad686c910</premis:messageDigest>
</premis:fixity>
<premis:size>6764115</premis:size>
<premis:format>
<premis:formatDesignation>
<premis:formatName>application/pdf</premis:formatName>
</premis:formatDesignation>
</premis:format>
</premis:objectCharacteristics>
<premis:originalName>ttw.pdf</premis:originalName>
</premis:object>
</premis:premis>
</xmlData>
</mdWrap>
</techMD>
</amdSec>
<amdSec ID="FT_10803_94492_2">
<techMD ID="TECH_T_10803_94492_2">
<mdWrap MDTYPE="PREMIS">
<xmlData schemaLocation="http://www.loc.gov/standards/premis http://www.loc.gov/standards/premis/PREMIS-v1-0.xsd">
<premis:premis>
<premis:object>
<premis:objectIdentifier>
<premis:objectIdentifierType>URL</premis:objectIdentifierType>
<premis:objectIdentifierValue>https://www.tdx.cat/bitstream/10803/94492/2/ttw.pdf.txt</premis:objectIdentifierValue>
</premis:objectIdentifier>
<premis:objectCategory>File</premis:objectCategory>
<premis:objectCharacteristics>
<premis:fixity>
<premis:messageDigestAlgorithm>MD5</premis:messageDigestAlgorithm>
<premis:messageDigest>757e893c917707af73bc0b832afad414</premis:messageDigest>
</premis:fixity>
<premis:size>194760</premis:size>
<premis:format>
<premis:formatDesignation>
<premis:formatName>text/plain</premis:formatName>
</premis:formatDesignation>
</premis:format>
</premis:objectCharacteristics>
<premis:originalName>ttw.pdf.txt</premis:originalName>
</premis:object>
</premis:premis>
</xmlData>
</mdWrap>
</techMD>
</amdSec>
<fileSec>
<fileGrp USE="ORIGINAL">
<file ADMID="FO_10803_94492_1" CHECKSUM="8e3b3f25dad03e902151005ad686c910" CHECKSUMTYPE="MD5" GROUPID="GROUP_BITSTREAM_10803_94492_1" ID="BITSTREAM_ORIGINAL_10803_94492_1" MIMETYPE="application/pdf" SEQ="1" SIZE="6764115">
</file>
</fileGrp>
<fileGrp USE="TEXT">
<file ADMID="FT_10803_94492_2" CHECKSUM="757e893c917707af73bc0b832afad414" CHECKSUMTYPE="MD5" GROUPID="GROUP_BITSTREAM_10803_94492_2" ID="BITSTREAM_TEXT_10803_94492_2" MIMETYPE="text/plain" SEQ="2" SIZE="194760">
</file>
</fileGrp>
</fileSec>
<structMap LABEL="DSpace Object" TYPE="LOGICAL">
<div ADMID="DMD_10803_94492" TYPE="DSpace Object Contents">
<div TYPE="DSpace BITSTREAM">
</div>
</div>
</structMap>
</mets>
<?xml version="1.0" encoding="UTF-8" ?>
<mods:mods schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
<mods:name>
<mods:namePart>Whitmarsh, Tristan</mods:namePart>
</mods:name>
<mods:extension>
<mods:dateAvailable encoding="iso8601">2012-11-14T09:43:13Z</mods:dateAvailable>
</mods:extension>
<mods:extension>
<mods:dateAccessioned encoding="iso8601">2012-11-14T09:43:13Z</mods:dateAccessioned>
</mods:extension>
<mods:originInfo>
<mods:dateIssued encoding="iso8601">2012-09-25</mods:dateIssued>
</mods:originInfo>
<mods:identifier type="uri">http://hdl.handle.net/10803/94492</mods:identifier>
<mods:identifier type="dl">B. 32040-2012</mods:identifier>
<mods:abstract>In this thesis a method was developed to reconstruct both the 3D shape and the BMD distribution of bone structures from Dual-energy X-ray Absorptiometry (DXA) images. The method incorporates a statistical model built from a large dataset of Quantitative Computed Tomography (QCT) scans together with a 3D-2D intensity based registration process. The method was evaluated for its ability to reconstruct the proximal femur from a single DXA image. The resulting parameters of the reconstructions were subsequently evaluated for their hip fracture discrimination ability. The reconstruction method was finally extended to the reconstruction of the lumbar vertebrae from anteroposterior and lateral DXA, thereby incorporating a multi-object and multi-view approach. These techniques can potentially improve the fracture risk estimation accuracy over current clinical practice.</mods:abstract>
<mods:abstract>En esta tesis se desarrolló un método para reconstruir tanto la forma 3D de estructuras óseas como la distribución de la DMO a partir de una sola imagen de DXA. El método incorpora un modelo estadístico construido a partir de una gran base de datos de QCT junto con una técnica de registro 3D-2D basada en intensidades. Se ha evaluado la capacidad del método para reconstruir la parte proximal del fémur a partir de una imagen DXA. Los parámetros resultantes de las reconstrucciones fueron evaluados posteriormente por su capacidad en discriminar una fractura de cadera. Por fin, se extendió el método a la reconstrucción de las vértebras lumbares a partir de DXA anteroposterior y lateral incorporando así un enfoque multi-objeto y multi-vista. Estos técnicas pueden potencialmente mejorar la precisión en la estimación del riesgo de fractura respecto a la estimación que ofrece la práctica clínica actual.</mods:abstract>
<mods:language>
<mods:languageTerm>eng</mods:languageTerm>
</mods:language>
<mods:accessCondition type="useAndReproduction">ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.</mods:accessCondition>
<mods:accessCondition type="useAndReproduction">info:eu-repo/semantics/openAccess</mods:accessCondition>
<mods:subject>
<mods:topic>Osteoporosis</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Fracture</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Fracture risk assessment</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Statistical model</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Registration</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Reconstruction</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Femur</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Vertebrae</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Computed Tomography</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Dual-energy</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>X-ray</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Absorptiometry</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Bone Mineral Density</mods:topic>
</mods:subject>
<mods:titleInfo>
<mods:title>3D reconstruction of the proximal femur and lumbar vertebrae from dual-energy x-ray absorptiometry for osteoporotic risk assessment</mods:title>
</mods:titleInfo>
<mods:genre>info:eu-repo/semantics/doctoralThesis</mods:genre>
<mods:genre>info:eu-repo/semantics/publishedVersion</mods:genre>
</mods:mods>
<?xml version="1.0" encoding="UTF-8" ?>
<oaire:record schemaLocation="http://namespaceopenaire.eu/schema/oaire/">
<dc:title>3D reconstruction of the proximal femur and lumbar vertebrae from dual-energy x-ray absorptiometry for osteoporotic risk assessment</dc:title>
<datacite:creator>
<datacite:creatorName>Whitmarsh, Tristan</datacite:creatorName>
</datacite:creator>
<datacite:contributor>twhitmarsh@cistib.upf.edu</datacite:contributor>
<datacite:contributor>true</datacite:contributor>
<datacite:contributor>Frangi Caregnato, Alejandro</datacite:contributor>
<datacite:contributor>Humbert, Ludovic</datacite:contributor>
<datacite:contributor>true</datacite:contributor>
<datacite:contributor>Universitat Pompeu Fabra. Departament de Tecnologies de la Informació i les Comunicacions</datacite:contributor>
<dc:subject>Osteoporosis</dc:subject>
<dc:subject>Fracture</dc:subject>
<dc:subject>Fracture risk assessment</dc:subject>
<dc:subject>Statistical model</dc:subject>
<dc:subject>Registration</dc:subject>
<dc:subject>Reconstruction</dc:subject>
<dc:subject>Femur</dc:subject>
<dc:subject>Vertebrae</dc:subject>
<dc:subject>Computed Tomography</dc:subject>
<dc:subject>Dual-energy</dc:subject>
<dc:subject>X-ray</dc:subject>
<dc:subject>Absorptiometry</dc:subject>
<dc:subject>Bone Mineral Density</dc:subject>
<dc:subject>62</dc:subject>
<dc:description>In this thesis a method was developed to reconstruct both the 3D shape and the BMD distribution of bone structures from Dual-energy X-ray Absorptiometry (DXA) images. The method incorporates a statistical model built from a large dataset of Quantitative Computed Tomography (QCT) scans together with a 3D-2D intensity based registration process. The method was evaluated for its ability to reconstruct the proximal femur from a single DXA image. The resulting parameters of the reconstructions were subsequently evaluated for their hip fracture discrimination ability. The reconstruction method was finally extended to the reconstruction of the lumbar vertebrae from anteroposterior and lateral DXA, thereby incorporating a multi-object and multi-view approach. These techniques can potentially improve the fracture risk estimation accuracy over current clinical practice.</dc:description>
<dc:description>En esta tesis se desarrolló un método para reconstruir tanto la forma 3D de estructuras óseas como la distribución de la DMO a partir de una sola imagen de DXA. El método incorpora un modelo estadístico construido a partir de una gran base de datos de QCT junto con una técnica de registro 3D-2D basada en intensidades. Se ha evaluado la capacidad del método para reconstruir la parte proximal del fémur a partir de una imagen DXA. Los parámetros resultantes de las reconstrucciones fueron evaluados posteriormente por su capacidad en discriminar una fractura de cadera. Por fin, se extendió el método a la reconstrucción de las vértebras lumbares a partir de DXA anteroposterior y lateral incorporando así un enfoque multi-objeto y multi-vista. Estos técnicas pueden potencialmente mejorar la precisión en la estimación del riesgo de fractura respecto a la estimación que ofrece la práctica clínica actual.</dc:description>
<dc:description>Programa de doctorat en Tecnologies de la Informació i les Comunicacions</dc:description>
<dc:date>2012-11-14T09:43:13Z</dc:date>
<dc:date>2012-11-14T09:43:13Z</dc:date>
<dc:date>2012-09-25</dc:date>
<dc:type>info:eu-repo/semantics/doctoralThesis</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<datacite:alternateIdentifier>http://hdl.handle.net/10803/94492</datacite:alternateIdentifier>
<datacite:alternateIdentifier>B. 32040-2012</datacite:alternateIdentifier>
<dc:language>eng</dc:language>
<dc:rights>ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.</dc:rights>
<dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
<dc:format>96 p.</dc:format>
<dc:format>application/pdf</dc:format>
<dc:format>application/pdf</dc:format>
<dc:publisher>Universitat Pompeu Fabra</dc:publisher>
<dc:source>TDX (Tesis Doctorals en Xarxa)</dc:source>
<oaire:file>https://www.tdx.cat/bitstream/10803/94492/1/ttw.pdf</oaire:file>
</oaire:record>
<?xml version="1.0" encoding="UTF-8" ?>
<atom:entry schemaLocation="http://www.w3.org/2005/Atom http://www.kbcafe.com/rss/atom.xsd.xml">
<atom:id>http://hdl.handle.net/10803/94492/ore.xml</atom:id>
<atom:published>2012-11-14T09:43:13Z</atom:published>
<atom:updated>2012-11-14T09:43:13Z</atom:updated>
<atom:source>
<atom:generator>TDX (Tesis Doctorals en Xarxa)</atom:generator>
</atom:source>
<atom:title>3D reconstruction of the proximal femur and lumbar vertebrae from dual-energy x-ray absorptiometry for osteoporotic risk assessment</atom:title>
<atom:author>
<atom:name>Whitmarsh, Tristan</atom:name>
</atom:author>
<oreatom:triples>
<rdf:Description about="http://hdl.handle.net/10803/94492/ore.xml#atom">
<dcterms:modified>2012-11-14T09:43:13Z</dcterms:modified>
</rdf:Description>
<rdf:Description about="https://www.tdx.cat/bitstream/10803/94492/1/ttw.pdf">
<dcterms:description>ORIGINAL</dcterms:description>
</rdf:Description>
<rdf:Description about="https://www.tdx.cat/bitstream/10803/94492/2/ttw.pdf.txt">
<dcterms:description>TEXT</dcterms:description>
</rdf:Description>
<rdf:Description about="https://www.tdx.cat/bitstream/10803/94492/3/ttw.pdf.xml">
<dcterms:description>MEDIA_DOCUMENT</dcterms:description>
</rdf:Description>
</oreatom:triples>
</atom:entry>
<?xml version="1.0" encoding="UTF-8" ?>
<qdc:qualifieddc schemaLocation="http://purl.org/dc/elements/1.1/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dc.xsd http://purl.org/dc/terms/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dcterms.xsd http://dspace.org/qualifieddc/ http://www.ukoln.ac.uk/metadata/dcmi/xmlschema/qualifieddc.xsd">
<dc:title>3D reconstruction of the proximal femur and lumbar vertebrae from dual-energy x-ray absorptiometry for osteoporotic risk assessment</dc:title>
<dc:creator>Whitmarsh, Tristan</dc:creator>
<dc:contributor>Frangi Caregnato, Alejandro</dc:contributor>
<dc:contributor>Humbert, Ludovic</dc:contributor>
<dc:subject>Osteoporosis</dc:subject>
<dc:subject>Fracture</dc:subject>
<dc:subject>Fracture risk assessment</dc:subject>
<dc:subject>Statistical model</dc:subject>
<dc:subject>Registration</dc:subject>
<dc:subject>Reconstruction</dc:subject>
<dc:subject>Femur</dc:subject>
<dc:subject>Vertebrae</dc:subject>
<dc:subject>Computed Tomography</dc:subject>
<dc:subject>Dual-energy</dc:subject>
<dc:subject>X-ray</dc:subject>
<dc:subject>Absorptiometry</dc:subject>
<dc:subject>Bone Mineral Density</dc:subject>
<dcterms:abstract>In this thesis a method was developed to reconstruct both the 3D shape and the BMD distribution of bone structures from Dual-energy X-ray Absorptiometry (DXA) images. The method incorporates a statistical model built from a large dataset of Quantitative Computed Tomography (QCT) scans together with a 3D-2D intensity based registration process. The method was evaluated for its ability to reconstruct the proximal femur from a single DXA image. The resulting parameters of the reconstructions were subsequently evaluated for their hip fracture discrimination ability. The reconstruction method was finally extended to the reconstruction of the lumbar vertebrae from anteroposterior and lateral DXA, thereby incorporating a multi-object and multi-view approach. These techniques can potentially improve the fracture risk estimation accuracy over current clinical practice.</dcterms:abstract>
<dcterms:abstract>En esta tesis se desarrolló un método para reconstruir tanto la forma 3D de estructuras óseas como la distribución de la DMO a partir de una sola imagen de DXA. El método incorpora un modelo estadístico construido a partir de una gran base de datos de QCT junto con una técnica de registro 3D-2D basada en intensidades. Se ha evaluado la capacidad del método para reconstruir la parte proximal del fémur a partir de una imagen DXA. Los parámetros resultantes de las reconstrucciones fueron evaluados posteriormente por su capacidad en discriminar una fractura de cadera. Por fin, se extendió el método a la reconstrucción de las vértebras lumbares a partir de DXA anteroposterior y lateral incorporando así un enfoque multi-objeto y multi-vista. Estos técnicas pueden potencialmente mejorar la precisión en la estimación del riesgo de fractura respecto a la estimación que ofrece la práctica clínica actual.</dcterms:abstract>
<dcterms:dateAccepted>2012-11-14T09:43:13Z</dcterms:dateAccepted>
<dcterms:available>2012-11-14T09:43:13Z</dcterms:available>
<dcterms:created>2012-11-14T09:43:13Z</dcterms:created>
<dcterms:issued>2012-09-25</dcterms:issued>
<dc:type>info:eu-repo/semantics/doctoralThesis</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:identifier>http://hdl.handle.net/10803/94492</dc:identifier>
<dc:identifier>B. 32040-2012</dc:identifier>
<dc:language>eng</dc:language>
<dc:rights>ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.</dc:rights>
<dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
<dc:publisher>Universitat Pompeu Fabra</dc:publisher>
<dc:source>TDX (Tesis Doctorals en Xarxa)</dc:source>
</qdc:qualifieddc>
<?xml version="1.0" encoding="UTF-8" ?>
<rdf:RDF schemaLocation="http://www.openarchives.org/OAI/2.0/rdf/ http://www.openarchives.org/OAI/2.0/rdf.xsd">
<ow:Publication about="oai:www.tdx.cat:10803/94492">
<dc:title>3D reconstruction of the proximal femur and lumbar vertebrae from dual-energy x-ray absorptiometry for osteoporotic risk assessment</dc:title>
<dc:creator>Whitmarsh, Tristan</dc:creator>
<dc:contributor>twhitmarsh@cistib.upf.edu</dc:contributor>
<dc:contributor>true</dc:contributor>
<dc:contributor>Frangi Caregnato, Alejandro</dc:contributor>
<dc:contributor>Humbert, Ludovic</dc:contributor>
<dc:contributor>true</dc:contributor>
<dc:subject>Osteoporosis</dc:subject>
<dc:subject>Fracture</dc:subject>
<dc:subject>Fracture risk assessment</dc:subject>
<dc:subject>Statistical model</dc:subject>
<dc:subject>Registration</dc:subject>
<dc:subject>Reconstruction</dc:subject>
<dc:subject>Femur</dc:subject>
<dc:subject>Vertebrae</dc:subject>
<dc:subject>Computed Tomography</dc:subject>
<dc:subject>Dual-energy</dc:subject>
<dc:subject>X-ray</dc:subject>
<dc:subject>Absorptiometry</dc:subject>
<dc:subject>Bone Mineral Density</dc:subject>
<dc:description>In this thesis a method was developed to reconstruct both the 3D shape and the BMD distribution of bone structures from Dual-energy X-ray Absorptiometry (DXA) images. The method incorporates a statistical model built from a large dataset of Quantitative Computed Tomography (QCT) scans together with a 3D-2D intensity based registration process. The method was evaluated for its ability to reconstruct the proximal femur from a single DXA image. The resulting parameters of the reconstructions were subsequently evaluated for their hip fracture discrimination ability. The reconstruction method was finally extended to the reconstruction of the lumbar vertebrae from anteroposterior and lateral DXA, thereby incorporating a multi-object and multi-view approach. These techniques can potentially improve the fracture risk estimation accuracy over current clinical practice.</dc:description>
<dc:description>En esta tesis se desarrolló un método para reconstruir tanto la forma 3D de estructuras óseas como la distribución de la DMO a partir de una sola imagen de DXA. El método incorpora un modelo estadístico construido a partir de una gran base de datos de QCT junto con una técnica de registro 3D-2D basada en intensidades. Se ha evaluado la capacidad del método para reconstruir la parte proximal del fémur a partir de una imagen DXA. Los parámetros resultantes de las reconstrucciones fueron evaluados posteriormente por su capacidad en discriminar una fractura de cadera. Por fin, se extendió el método a la reconstrucción de las vértebras lumbares a partir de DXA anteroposterior y lateral incorporando así un enfoque multi-objeto y multi-vista. Estos técnicas pueden potencialmente mejorar la precisión en la estimación del riesgo de fractura respecto a la estimación que ofrece la práctica clínica actual.</dc:description>
<dc:date>2012-11-14T09:43:13Z</dc:date>
<dc:date>2012-11-14T09:43:13Z</dc:date>
<dc:date>2012-09-25</dc:date>
<dc:type>info:eu-repo/semantics/doctoralThesis</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:identifier>http://hdl.handle.net/10803/94492</dc:identifier>
<dc:identifier>B. 32040-2012</dc:identifier>
<dc:language>eng</dc:language>
<dc:rights>ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.</dc:rights>
<dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
<dc:publisher>Universitat Pompeu Fabra</dc:publisher>
<dc:source>TDX (Tesis Doctorals en Xarxa)</dc:source>
</ow:Publication>
</rdf:RDF>
<?xml version="1.0" encoding="UTF-8" ?>
<uketd_dc:uketddc schemaLocation="http://naca.central.cranfield.ac.uk/ethos-oai/2.0/ http://naca.central.cranfield.ac.uk/ethos-oai/2.0/uketd_dc.xsd">
<dc:title>3D reconstruction of the proximal femur and lumbar vertebrae from dual-energy x-ray absorptiometry for osteoporotic risk assessment</dc:title>
<dc:creator>Whitmarsh, Tristan</dc:creator>
<dcterms:abstract>In this thesis a method was developed to reconstruct both the 3D shape and the BMD distribution of bone structures from Dual-energy X-ray Absorptiometry (DXA) images. The method incorporates a statistical model built from a large dataset of Quantitative Computed Tomography (QCT) scans together with a 3D-2D intensity based registration process. The method was evaluated for its ability to reconstruct the proximal femur from a single DXA image. The resulting parameters of the reconstructions were subsequently evaluated for their hip fracture discrimination ability. The reconstruction method was finally extended to the reconstruction of the lumbar vertebrae from anteroposterior and lateral DXA, thereby incorporating a multi-object and multi-view approach. These techniques can potentially improve the fracture risk estimation accuracy over current clinical practice.</dcterms:abstract>
<dcterms:abstract>En esta tesis se desarrolló un método para reconstruir tanto la forma 3D de estructuras óseas como la distribución de la DMO a partir de una sola imagen de DXA. El método incorpora un modelo estadístico construido a partir de una gran base de datos de QCT junto con una técnica de registro 3D-2D basada en intensidades. Se ha evaluado la capacidad del método para reconstruir la parte proximal del fémur a partir de una imagen DXA. Los parámetros resultantes de las reconstrucciones fueron evaluados posteriormente por su capacidad en discriminar una fractura de cadera. Por fin, se extendió el método a la reconstrucción de las vértebras lumbares a partir de DXA anteroposterior y lateral incorporando así un enfoque multi-objeto y multi-vista. Estos técnicas pueden potencialmente mejorar la precisión en la estimación del riesgo de fractura respecto a la estimación que ofrece la práctica clínica actual.</dcterms:abstract>
<uketdterms:institution>Universitat Pompeu Fabra</uketdterms:institution>
<dcterms:issued>2012-09-25</dcterms:issued>
<dc:type>info:eu-repo/semantics/doctoralThesis</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:language type="dcterms:ISO639-2">eng</dc:language>
<dcterms:isReferencedBy>http://hdl.handle.net/10803/94492</dcterms:isReferencedBy>
<dc:identifier type="dcterms:URI">https://www.tdx.cat/bitstream/10803/94492/1/ttw.pdf</dc:identifier>
<uketdterms:checksum type="uketdterms:MD5">8e3b3f25dad03e902151005ad686c910</uketdterms:checksum>
<dcterms:hasFormat>https://www.tdx.cat/bitstream/10803/94492/2/ttw.pdf.txt</dcterms:hasFormat>
<uketdterms:checksum type="uketdterms:MD5">757e893c917707af73bc0b832afad414</uketdterms:checksum>
<uketdterms:embargodate>cap</uketdterms:embargodate>
<dc:subject>Osteoporosis</dc:subject>
<dc:subject>Fracture</dc:subject>
<dc:subject>Fracture risk assessment</dc:subject>
<dc:subject>Statistical model</dc:subject>
<dc:subject>Registration</dc:subject>
<dc:subject>Reconstruction</dc:subject>
<dc:subject>Femur</dc:subject>
<dc:subject>Vertebrae</dc:subject>
<dc:subject>Computed Tomography</dc:subject>
<dc:subject>Dual-energy</dc:subject>
<dc:subject>X-ray</dc:subject>
<dc:subject>Absorptiometry</dc:subject>
<dc:subject>Bone Mineral Density</dc:subject>
</uketd_dc:uketddc>
<?xml version="1.0" encoding="UTF-8" ?>
<metadata schemaLocation="http://www.lyncode.com/xoai http://www.lyncode.com/xsd/xoai.xsd">
<element name="dc">
<element name="contributor">
<element name="none">
<field name="value">Universitat Pompeu Fabra. Departament de Tecnologies de la Informació i les Comunicacions</field>
</element>
<element name="author">
<element name="none">
<field name="value">Whitmarsh, Tristan</field>
<field name="authority">d0e6c0c8-bd39-4ee8-b532-ecbf32ed20c2</field>
<field name="confidence">-1</field>
</element>
</element>
<element name="authoremail">
<element name="cat">
<field name="value">twhitmarsh@cistib.upf.edu</field>
</element>
</element>
<element name="authoremailshow">
<element name="cat">
<field name="value">true</field>
</element>
</element>
<element name="director">
<element name="none">
<field name="value">Frangi Caregnato, Alejandro</field>
<field name="authority">c0a5d95e-a11f-4c95-b030-c6cd5ff231c2</field>
<field name="confidence">-1</field>
<field name="value">Humbert, Ludovic</field>
<field name="authority">0f121804-7de0-40f0-b1d8-a3d2926b5978</field>
<field name="confidence">-1</field>
</element>
</element>
<element name="authorsendemail">
<element name="cat">
<field name="value">true</field>
</element>
</element>
</element>
<element name="date">
<element name="accessioned">
<element name="none">
<field name="value">2012-11-14T09:43:13Z</field>
</element>
</element>
<element name="available">
<element name="none">
<field name="value">2012-11-14T09:43:13Z</field>
</element>
</element>
<element name="issued">
<element name="none">
<field name="value">2012-09-25</field>
</element>
</element>
</element>
<element name="identifier">
<element name="uri">
<element name="none">
<field name="value">http://hdl.handle.net/10803/94492</field>
</element>
</element>
<element name="dl">
<element name="cat">
<field name="value">B. 32040-2012</field>
</element>
</element>
</element>
<element name="description">
<element name="abstract">
<element name="eng">
<field name="value">In this thesis a method was developed to reconstruct both the 3D shape and the BMD distribution of bone structures from Dual-energy X-ray Absorptiometry (DXA) images. The method incorporates a statistical model built from a large dataset of Quantitative Computed Tomography (QCT) scans together with a 3D-2D intensity based registration process. The method was evaluated for its ability to reconstruct the proximal femur from a single DXA image. The resulting parameters of the reconstructions were subsequently evaluated for their hip fracture discrimination ability. The reconstruction method was finally extended to the reconstruction of the lumbar vertebrae from anteroposterior and lateral DXA, thereby incorporating a multi-object and multi-view approach. These techniques can potentially improve the fracture risk estimation accuracy over current clinical practice.</field>
</element>
<element name="spa">
<field name="value">En esta tesis se desarrolló un método para reconstruir tanto la forma 3D de estructuras óseas como la distribución de la DMO a partir de una sola imagen de DXA. El método incorpora un modelo estadístico construido a partir de una gran base de datos de QCT junto con una técnica de registro 3D-2D basada en intensidades. Se ha evaluado la capacidad del método para reconstruir la parte proximal del fémur a partir de una imagen DXA. Los parámetros resultantes de las reconstrucciones fueron evaluados posteriormente por su capacidad en discriminar una fractura de cadera. Por fin, se extendió el método a la reconstrucción de las vértebras lumbares a partir de DXA anteroposterior y lateral incorporando así un enfoque multi-objeto y multi-vista. Estos técnicas pueden potencialmente mejorar la precisión en la estimación del riesgo de fractura respecto a la estimación que ofrece la práctica clínica actual.</field>
</element>
</element>
<element name="degree">
<element name="none">
<field name="value">Programa de doctorat en Tecnologies de la Informació i les Comunicacions</field>
</element>
</element>
</element>
<element name="format">
<element name="extent">
<element name="cat">
<field name="value">96 p.</field>
</element>
</element>
<element name="mimetype">
<element name="none">
<field name="value">application/pdf</field>
</element>
</element>
</element>
<element name="language">
<element name="iso">
<element name="cat">
<field name="value">eng</field>
</element>
</element>
</element>
<element name="publisher">
<element name="none">
<field name="value">Universitat Pompeu Fabra</field>
</element>
</element>
<element name="rights">
<element name="license">
<element name="none">
<field name="value">ADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.</field>
</element>
</element>
<element name="accessLevel">
<element name="none">
<field name="value">info:eu-repo/semantics/openAccess</field>
</element>
</element>
</element>
<element name="source">
<element name="none">
<field name="value">TDX (Tesis Doctorals en Xarxa)</field>
</element>
</element>
<element name="subject">
<element name="cat">
<field name="value">Osteoporosis</field>
<field name="value">Fracture</field>
<field name="value">Fracture risk assessment</field>
<field name="value">Statistical model</field>
<field name="value">Registration</field>
<field name="value">Reconstruction</field>
<field name="value">Femur</field>
<field name="value">Vertebrae</field>
<field name="value">Computed Tomography</field>
<field name="value">Dual-energy</field>
<field name="value">X-ray</field>
<field name="value">Absorptiometry</field>
<field name="value">Bone Mineral Density</field>
</element>
<element name="udc">
<element name="cat">
<field name="value">62</field>
</element>
</element>
</element>
<element name="title">
<element name="cat">
<field name="value">3D reconstruction of the proximal femur and lumbar vertebrae from dual-energy x-ray absorptiometry for osteoporotic risk assessment</field>
</element>
</element>
<element name="type">
<element name="none">
<field name="value">info:eu-repo/semantics/doctoralThesis</field>
<field name="value">info:eu-repo/semantics/publishedVersion</field>
</element>
</element>
<element name="embargo">
<element name="terms">
<element name="cat">
<field name="value">cap</field>
</element>
</element>
</element>
</element>
<element name="bundles">
<element name="bundle">
<field name="name">ORIGINAL</field>
<element name="bitstreams">
<element name="bitstream">
<field name="name">ttw.pdf</field>
<field name="originalName">ttw.pdf</field>
<field name="format">application/pdf</field>
<field name="size">6764115</field>
<field name="url">https://www.tdx.cat/bitstream/10803/94492/1/ttw.pdf</field>
<field name="checksum">8e3b3f25dad03e902151005ad686c910</field>
<field name="checksumAlgorithm">MD5</field>
<field name="sid">1</field>
<field name="drm">open access</field>
</element>
</element>
</element>
<element name="bundle">
<field name="name">TEXT</field>
<element name="bitstreams">
<element name="bitstream">
<field name="name">ttw.pdf.txt</field>
<field name="originalName">ttw.pdf.txt</field>
<field name="description">Extracted Text</field>
<field name="format">text/plain</field>
<field name="size">194760</field>
<field name="url">https://www.tdx.cat/bitstream/10803/94492/2/ttw.pdf.txt</field>
<field name="checksum">757e893c917707af73bc0b832afad414</field>
<field name="checksumAlgorithm">MD5</field>
<field name="sid">2</field>
<field name="drm">open access</field>
</element>
</element>
</element>
<element name="bundle">
<field name="name">MEDIA_DOCUMENT</field>
<element name="bitstreams">
<element name="bitstream">
<field name="name">ttw.pdf.xml</field>
<field name="originalName">ttw.pdf.xml</field>
<field name="description">Document Consulta</field>
<field name="format">text/xml</field>
<field name="size">105</field>
<field name="url">https://www.tdx.cat/bitstream/10803/94492/3/ttw.pdf.xml</field>
<field name="checksum">2d5e5e6f8ca67918efbb83298a93ba27</field>
<field name="checksumAlgorithm">MD5</field>
<field name="sid">3</field>
<field name="drm">open access</field>
</element>
</element>
</element>
</element>
<element name="others">
<field name="handle">10803/94492</field>
<field name="identifier">oai:www.tdx.cat:10803/94492</field>
<field name="lastModifyDate">2024-03-15 11:58:03.749</field>
<field name="drm">open access</field>
</element>
<element name="repository">
<field name="name">TDX (Tesis Doctorals en Xarxa)</field>
<field name="mail">pir@csuc.cat</field>
</element>
</metadata>